Beckett CF500の取扱説明書

16ページ 1.21 mb
ダウンロード

ページに移動 of 16

Summary
  • Beckett CF500 - page 1

    6104 BCF5 R06 Page 1 Potential for Fire, Smoke and Asphyxiation Hazards T o the Homeowner or Equipment Owner : Please read and carefully follow all instructions provided in this manual regarding your responsibilities in caring for your heating equipment. Contact a professional, quali fi ed service agency for installation, start-up or service work. ...

  • Beckett CF500 - page 2

    Page 2 6104 BCF5 R06 T able of Contents General Information .............................................................................................................................. . 3-4 T o the Owner ............................................................................................................................................... ...

  • Beckett CF500 - page 3

    6104 BCF5 R06 Page 3 Hazar d de fi nitions Intended to bring special attention to information, but not related to personal injury or property damage. NO TICE Indicates a potentially hazardous situation, which, if not avoided, may result in person- al injury or property damage. Indicates a potentially hazardous situation, which, if not avoided, cou ...

  • Beckett CF500 - page 4

    Page 4 6104 BCF5 R06 Owner ’ s Responsibility: Follow These Instructions Exactly Contact a professional, quali fi ed service agency for the installation, adjustment and service of your oil burning system. Thereafter , have your equipment adjusted and inspected at least annually to ensure reliable operation. This work requires technical training, ...

  • Beckett CF500 - page 5

    6104 BCF5 R06 Page 5 Combustion air supply The burner requires combustion air and ventilation air for reliable operation. Assure that the building and/or com- bustion air openings comply with National Fire Protec- tion Standard for Oil-Burning Equipment, NFP A 31. For appliance/burner units in con fi ned spaces, the room must have an air opening n ...

  • Beckett CF500 - page 6

    Page 6 6104 BCF5 R06 Figure 1. Min. Combustion Chamber Dimensions V erify fi ring rate Refer to appliance manufacturer ’ s instructions (if available) for fi ring rate and nozzle selection. Otherwise, the maximum recommended fi ring rate for the burner depends on the length of the fi ring chamber and the distance from the burner center to the ...

  • Beckett CF500 - page 7

    6104 BCF5 R06 Page 7 Mount the bur ner Mount fl ange(s) on air tube This section does not apply to burners with welded fl ang- es. Do not install air tube on burner . For non-pr essure fi ring fl ange , refer to Figure 3 : Install gasket (item a ) and fl ange (item d ). Ignore the next paragraph. For pr essur e- fi ring fl ange , refer to Fi ...

  • Beckett CF500 - page 8

    Page 8 6104 BCF5 R06 Install nozzle line assembl y Insert the nozzle line assembly into the burner air tube. Reference Figure 5 . Slide the secondary adjusting plate ( Figure 6 , item f ) com- pletely to the left on the indicator adjusting plate (item e ). Finger tighten acorn nut (item c ) to secure the two plates together . Slide both plates comp ...

  • Beckett CF500 - page 9

    6104 BCF5 R06 Page 9 The burner is shipped without the by-pass plug in- stalled. Intall the by-pass plug in two-pipe oil supply systems ONL Y . y y Failure to comply could cause immediate pump seal failure, pressurized oil leakage and the po- tential for a fi re and injury hazard. Do Not Install By-pass Plug with 1-Pipe System Install the oil tank ...

  • Beckett CF500 - page 10

    Page 10 6104 BCF5 R06 W ir e the bur ner — R7184 Disconnect electrical power before installing or servic- ing the burner . Provide ground wiring to the burner , metal control en- closures and accessories. (This may also be required to aid proper control system operation) Perform all wiring in compliance with the National Electric Code ANSI/NFP A ...

  • Beckett CF500 - page 11

    6104 BCF5 R06 Page 1 1 Star t-up chec klist Combustion air supply and venting have been inspected and veri fi ed to be free of obstructions and installed in ac- cordance with all applicable codes. Oil nozzle has been selected correctly and securely in- stalled in the nozzle adapter . Fuel unit by-pass plug has not been installed for one- pipe oil ...

  • Beckett CF500 - page 12

    Page 12 6104 BCF5 R06 Star t the Bur ner Do not attempt to start the burner when excess oil has accumulated in the appliance, the appliance is full of vapor , or when the combustion chamber is very hot. Do not attempt to re-establish fl ame with the burner running if the fl ame becomes extinguished during start- up, venting, or adjustment. V apor ...

  • Beckett CF500 - page 13

    6104 BCF5 R06 Page 13 Set combustion using instr uments Allow the burner to run for approximately 5 to 10 min- utes. Set the stack or over- fi re draft to the level speci fi ed by the appliance manufacturer . Natural Draft Applications; typically over- fi re draft is -0.01” or -0.02” w .c. Direct V enting ; typically may not require draft ad ...

  • Beckett CF500 - page 14

    Page 14 6104 BCF5 R06 Maintenance and Ser vice Do not tamper with the burner or controls or make any adjustments unless you are a trained and quali fi ed service technician. T o ensure continued reliable operation, a quali fi ed service technician must service this burner annually . More frequent service intervals may be required in dusty or adve ...

  • Beckett CF500 - page 15

    6104 BCF5 R06 Page 15 R eplacement par ts 1 2 3 10 9 8 4 5 6 7 11 12 13 15 14 16 Item Part Name/Description Part Number 1 Air T ube Specify 2 Spline Nut 3666 3 Adjusting plate assembly 51286U 4 Blocking Oil Solenoid V alve 2182602U 5 Igniter 51771U 6 Control Specify 7 Air Band 3819 8 Air Shutter 3215 9 Fuel Pump Specify 10 Fuel lines Specify Length ...

  • Beckett CF500 - page 16

    Page 16 6104 BCF5 R06 Limited WARRANTY For Residential, Commercial and Specialty Burners The R. W. BECKETT CORPORATION (“Beckett”) warrants to persons who purchase its Beckett burners from Beckett for resale or for incorporation into a product for resale (“Customers”) that its equipment is free from defects in material and workmanship under ...

メーカー Beckett カテゴリー Burner

Beckett CF500のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CF500の取扱説明書
- Beckettの製品カード
- パンフレット
- またはBeckett CF500の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Beckett CF500の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Beckett CF500の取り付け説明書、サービスマニュアル、簡易説明書、またはBeckett CF500のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Beckett CF500の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Beckett CF500デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBeckett CF500を使用するのを助ける技術的文書のことです。説明書は通常、全てのBeckett CF500ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Beckettの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Beckett CF500の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBeckett CF500の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Beckett CF500に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Beckett CF500デバイスの基本機能を使うにあたってのヒント。 Beckett CF500のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Beckett CF500に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBeckett CF500のメーカー/サービスへの連絡先に関する情報。

Beckett CF500についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBeckett CF500の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBeckett CF500で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)