Manual Beckett CF500

16 pages 1.21 mb
Download

Go to site of 16

Summary
  • Beckett CF500 - page 1

    6104 BCF5 R06 Page 1 Potential for Fire, Smoke and Asphyxiation Hazards T o the Homeowner or Equipment Owner : Please read and carefully follow all instructions provided in this manual regarding your responsibilities in caring for your heating equipment. Contact a professional, quali fi ed service agency for installation, start-up or service work. ...

  • Beckett CF500 - page 2

    Page 2 6104 BCF5 R06 T able of Contents General Information .............................................................................................................................. . 3-4 T o the Owner ............................................................................................................................................... ...

  • Beckett CF500 - page 3

    6104 BCF5 R06 Page 3 Hazar d de fi nitions Intended to bring special attention to information, but not related to personal injury or property damage. NO TICE Indicates a potentially hazardous situation, which, if not avoided, may result in person- al injury or property damage. Indicates a potentially hazardous situation, which, if not avoided, cou ...

  • Beckett CF500 - page 4

    Page 4 6104 BCF5 R06 Owner ’ s Responsibility: Follow These Instructions Exactly Contact a professional, quali fi ed service agency for the installation, adjustment and service of your oil burning system. Thereafter , have your equipment adjusted and inspected at least annually to ensure reliable operation. This work requires technical training, ...

  • Beckett CF500 - page 5

    6104 BCF5 R06 Page 5 Combustion air supply The burner requires combustion air and ventilation air for reliable operation. Assure that the building and/or com- bustion air openings comply with National Fire Protec- tion Standard for Oil-Burning Equipment, NFP A 31. For appliance/burner units in con fi ned spaces, the room must have an air opening n ...

  • Beckett CF500 - page 6

    Page 6 6104 BCF5 R06 Figure 1. Min. Combustion Chamber Dimensions V erify fi ring rate Refer to appliance manufacturer ’ s instructions (if available) for fi ring rate and nozzle selection. Otherwise, the maximum recommended fi ring rate for the burner depends on the length of the fi ring chamber and the distance from the burner center to the ...

  • Beckett CF500 - page 7

    6104 BCF5 R06 Page 7 Mount the bur ner Mount fl ange(s) on air tube This section does not apply to burners with welded fl ang- es. Do not install air tube on burner . For non-pr essure fi ring fl ange , refer to Figure 3 : Install gasket (item a ) and fl ange (item d ). Ignore the next paragraph. For pr essur e- fi ring fl ange , refer to Fi ...

  • Beckett CF500 - page 8

    Page 8 6104 BCF5 R06 Install nozzle line assembl y Insert the nozzle line assembly into the burner air tube. Reference Figure 5 . Slide the secondary adjusting plate ( Figure 6 , item f ) com- pletely to the left on the indicator adjusting plate (item e ). Finger tighten acorn nut (item c ) to secure the two plates together . Slide both plates comp ...

  • Beckett CF500 - page 9

    6104 BCF5 R06 Page 9 The burner is shipped without the by-pass plug in- stalled. Intall the by-pass plug in two-pipe oil supply systems ONL Y . y y Failure to comply could cause immediate pump seal failure, pressurized oil leakage and the po- tential for a fi re and injury hazard. Do Not Install By-pass Plug with 1-Pipe System Install the oil tank ...

  • Beckett CF500 - page 10

    Page 10 6104 BCF5 R06 W ir e the bur ner — R7184 Disconnect electrical power before installing or servic- ing the burner . Provide ground wiring to the burner , metal control en- closures and accessories. (This may also be required to aid proper control system operation) Perform all wiring in compliance with the National Electric Code ANSI/NFP A ...

  • Beckett CF500 - page 11

    6104 BCF5 R06 Page 1 1 Star t-up chec klist Combustion air supply and venting have been inspected and veri fi ed to be free of obstructions and installed in ac- cordance with all applicable codes. Oil nozzle has been selected correctly and securely in- stalled in the nozzle adapter . Fuel unit by-pass plug has not been installed for one- pipe oil ...

  • Beckett CF500 - page 12

    Page 12 6104 BCF5 R06 Star t the Bur ner Do not attempt to start the burner when excess oil has accumulated in the appliance, the appliance is full of vapor , or when the combustion chamber is very hot. Do not attempt to re-establish fl ame with the burner running if the fl ame becomes extinguished during start- up, venting, or adjustment. V apor ...

  • Beckett CF500 - page 13

    6104 BCF5 R06 Page 13 Set combustion using instr uments Allow the burner to run for approximately 5 to 10 min- utes. Set the stack or over- fi re draft to the level speci fi ed by the appliance manufacturer . Natural Draft Applications; typically over- fi re draft is -0.01” or -0.02” w .c. Direct V enting ; typically may not require draft ad ...

  • Beckett CF500 - page 14

    Page 14 6104 BCF5 R06 Maintenance and Ser vice Do not tamper with the burner or controls or make any adjustments unless you are a trained and quali fi ed service technician. T o ensure continued reliable operation, a quali fi ed service technician must service this burner annually . More frequent service intervals may be required in dusty or adve ...

  • Beckett CF500 - page 15

    6104 BCF5 R06 Page 15 R eplacement par ts 1 2 3 10 9 8 4 5 6 7 11 12 13 15 14 16 Item Part Name/Description Part Number 1 Air T ube Specify 2 Spline Nut 3666 3 Adjusting plate assembly 51286U 4 Blocking Oil Solenoid V alve 2182602U 5 Igniter 51771U 6 Control Specify 7 Air Band 3819 8 Air Shutter 3215 9 Fuel Pump Specify 10 Fuel lines Specify Length ...

  • Beckett CF500 - page 16

    Page 16 6104 BCF5 R06 Limited WARRANTY For Residential, Commercial and Specialty Burners The R. W. BECKETT CORPORATION (“Beckett”) warrants to persons who purchase its Beckett burners from Beckett for resale or for incorporation into a product for resale (“Customers”) that its equipment is free from defects in material and workmanship under ...

Manufacturer Beckett Category Burner

Documents that we receive from a manufacturer of a Beckett CF500 can be divided into several groups. They are, among others:
- Beckett technical drawings
- CF500 manuals
- Beckett product data sheets
- information booklets
- or energy labels Beckett CF500
All of them are important, but the most important information from the point of view of use of the device are in the user manual Beckett CF500.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Beckett CF500, service manual, brief instructions and user manuals Beckett CF500. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Beckett CF500.

Similar manuals

A complete manual for the device Beckett CF500, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Beckett CF500 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Beckett CF500.

A complete Beckett manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Beckett CF500 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Beckett CF500, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Beckett CF500, that we can find in the current document
3. Tips how to use the basic functions of the device Beckett CF500 - which should help us in our first steps of using Beckett CF500
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Beckett CF500
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Beckett CF500 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Beckett CF500?

Use the form below

If you did not solve your problem by using a manual Beckett CF500, ask a question using the form below. If a user had a similar problem with Beckett CF500 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)