    -1- INDUSTRIAL T ri-segment Medi a Converter KCD-302 Series Installation Guide DOC.060301-KCD-302 ...

  • KTI Networks KCD-302 Series - page 2

    -2- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documen- tation may be reproduced in any form or by any means or used to make any directive work (such as translation or transformation) without per- mission from KTI Networks Inc. KTI Networks Inc. reserves the right to revise this documentation and to make changes in content from ...

  • KTI Networks KCD-302 Series - page 3

    -3- The information contained in this document is subject to change without prior notice. Copyright (C) All Rights Reserved. TRADEMARKS Ethernet is a registered trademark of Xerox Corp. FCC NOTICE This device complies with Class B Part 15 the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful inte ...

  • KTI Networks KCD-302 Series - page 4

    -4- T a ble of Contents 1. Introduction ......................................................... 5 1.1 Features ........................................................................................ 7 1.2 Specifications ................................................................................ 8 1.3 Model Specifications ................... ...

  • KTI Networks KCD-302 Series - page 5

    -5- 1. Introduction The industrial tri-segment media converter series provides one 10/100BASE- TX Fast Ethernet port and two 100BASE-FX ports. It supports the connec- tions to three network segments, one UTP and two fiber cables. It serves the network data transfer between any two segments in switching basis. The following figure illustrates a basi ...

  • KTI Networks KCD-302 Series - page 6

    -6- For industrial environment, the converters are designed with the follow- ing enhanced features exceeding that of commercial media converters:  High a nd wide operating T emperature ra nge  W ide operating voltage ra nge for DC power input  Power input interface: Screw terminal block and DC jack for adapter  DIN rail mounting support ...

  • KTI Networks KCD-302 Series - page 7

    -7- 1.1 Features • Support network data transfer at full wire speed • The TP port supports 10Mbps and 100Mbps connections • Auto MDI/MDI-X detection function on the TP (copper) port • Auto-negotiation function on the TP port • Transparent conversion to 802.1Q VLAN tagged packets between any two segments • Far End Fault function on FX (f ...

  • KTI Networks KCD-302 Series - page 8

    -8- 1.2 Specifications This figure shows the important components of the converter: ...

  • KTI Networks KCD-302 Series - page 9

    -9- T wisted-Pair Interfa ce (TP Por t, or called copper Por t) Connector Shielded RJ-45 Pin Assignments Auto MDI/MDI-X detection Signal Compliance IEEE 802.3 10BASE-T , 802.3u 100BASE-TX Data Speed 10Mbps or 100Mbps Duplex Mode Half-duplex or Full-duplex Configuration Auto-negotiation capable and optional forced manual settings Ca ble T ypes 10Mbp ...

  • KTI Networks KCD-302 Series - page 10

    -10- Configuration Setting Switches (SW) NO. FUNCTION SETTINGS SW1 TP Port mode O FF Auto-negotiation (default) O N Forced mode SW2 TP Port Duplex O F F Full duplex (default) O N Half duplex SW3 TP Port Speed O FF 100Mbps (default) ON 10Mbps SW4 802.3x function O FF Enable (default) O N Disable SW5 FX1 port duplex O F F Full duplex mode (default) O ...

  • KTI Networks KCD-302 Series - page 11

    -11- DC Power Input Interface Screw-type terminal block (2 sets for power wire cascading) DC Jack ( -D 6.3mm / + D 2.0mm) Operating Input V oltages +7V ~ +30V(+5%) Power c on s um ption 2.7W max. @7.5VDC input 2.9W max. @24VDC input 3.0W max. @+30VDC input Basic Information MAC Addresses Entries 1 K Forwarding Throughput Full wire speed at 100M ful ...

  • KTI Networks KCD-302 Series - page 12

    -12- Certificate F C C Part 15 Class B CE/EMC EMI EN50081-1 Class B EMS EN55024 CE/L V D Safe ty E N 60950 EN 50081-1/1992 : EN55022:1994/A1:1995/A2:1997 CISPR Class B EN61000-3-2:2000 Device <75W EN61000-3-3:1995/A1:2001 Clause 5 EN 55024:1998/A1:2001 IEC 61000-4-2:1995 ESD T est IEC 61000-4-3:1995 RS T est IEC 61000-4-4:1995 EFT/BURST T est IE ...

  • KTI Networks KCD-302 Series - page 13

    -13- 1.3 Model Specifications The media converter series provides the following fiber options: KCD-302-xxx WaveL. Reference Operating Model Ext. FX Connectors (nm) Fiber Distance Te mperature -2T FX1 : ST MMF 1310 2 k m -10 ~ 70 o C FX2 : ST MMF 1310 2 km -10 ~ 70 o C -2C FX1 : SC MMF 1310 2 k m -10 ~ 70 o C FX2 : SC MMF 1310 2 k m -10 ~ 70 o C -2C ...

  • KTI Networks KCD-302 Series - page 14

    -14- 1.4 Special Functions Auto MDI/MDI-X Function This function allows the TP port to auto-detect the twisted-pair signals and adapts itself to form a valid MDI to MDI-X connection with the remote connected device automatically . Auto-negotiation Function When TP port is set on Auto-negotiation mode (SW1:ON), it is featured with auto-negotiation f ...

  • KTI Networks KCD-302 Series - page 15

    -15- 2. Installation 2.1 Unpacking Check that the following components have been included: • Information CD • The product unit • DIN-rail mounting bracket If any item is found missing or damaged, please contact your local reseller for replacement. The following are available optional accessories: • Panel Mounting Bracket The bracket is used ...

  • KTI Networks KCD-302 Series - page 16

    -16- 2.2 DIN-Rail Mounting In the product package, a DIN-rail bracket is provided for mounting the converter in a industrial DIN-rail enclosure. The steps to mount the device onto a DIN-rail are: 1. Clamp the bracket into the rear of the device. Align the bracket with the rear face of the device and screw it onto the device unit. ...

  • KTI Networks KCD-302 Series - page 17

    -17- 2. Unscrew and loose the mounting clamp plate of the bracket. Mount the bracket with the device onto the DIN rail. 5. Screw the clamp with the bracket and make sure the device is properly fixed on the DIN rail. ...

  • KTI Networks KCD-302 Series - page 18

    -18- M ake sure that there are proper heat dissi pation from a nd a dequate ven- tilation around the device. The final mechanical dimensions after installing DIN rail mounting bracket are: ...

  • KTI Networks KCD-302 Series - page 19

    -19- 2.3 Mounting on a Panel Surface An optional mounting bracket, as shown below is also available for mount- ing the device on a panel surface such as a wall, a wood board, or a metal plate in an industrial enclosure. T o mount the device on a pa nel surface, the ste ps are: 1. Clamp the bracket into the device and align the bracket with the bott ...

  • KTI Networks KCD-302 Series - page 20

    -20- 2. Mount a nd screw the device on the target surface. The final dimen- sion after bracket installation is also shown below: Make sure that there are proper heat dissipation from and adequate ven- tilation around the device. Do not place heavy objects on the device. ...

  • KTI Networks KCD-302 Series - page 21

    -21- 2.4 Applying Power The product provide two types of power interfaces, terminal block and DC power ja ck for receiving DC power input from external power supply . DC Power Input Specification Operating V oltage + 7 ~ +30VDC Power Consumption Max. 3.0W @30VDC DC Power T erminal Block Connectors Screw-type T erminal block (2 sets) Pin Assignments ...

  • KTI Networks KCD-302 Series - page 22

    -22- DC2 + a nd DC2 - ca n be installed with a nother power-pair f or delivering the main power input to next converter in a ca sca ding way . Note: Only up to four device units can be cascaded to receive power from one main power input source. DC Power Jack Connector: Jack D 6.3mm D 2.0mm AC Power Adapters: Optional commercial rated adapters are a ...

  • KTI Networks KCD-302 Series - page 23

    -23- 2.5 Making TP Port Connection TP port is featured to support connection to : • Auto-negotiation devices • Auto-negotiation incapable 10BASE-T devices • Auto-negotiation incapable 100BASE-TX devices Network Cables 10BASE-T : 2-pair UTP Cat. 3,4,5 , EIA/TIA-568B 100-ohm STP 100BASE-TX: 2-pair UTP Cat. 5, EIA/TIA-568B 100-ohm STP Link dista ...

  • KTI Networks KCD-302 Series - page 24

    -24- 2.6 Ma king FX Port Connection s FX1 port and FX2 port operate on 100Mbps and full duplex (factory default). A variety of fiber options is provided as listed in Section 1.3. Network Cables Multimode (MMF) - 50/125, 62.5/125 Single mode (SMF) - 9/125 ...

  • KTI Networks KCD-302 Series - page 25

    -25- 3 Configuration Switches & LED Indicators The following figure shows the locations of the configuration switches and LED indicators: Refer to the following sections for the related functions. ...

  • KTI Networks KCD-302 Series - page 26

    -26- 3.1 Configuration Switche s SW FUNCTION SETTING & ST A TE SW 1 TP Port mode OFF Auto-negotiation (default) O N Forced mode SW2 TP Port Duplex O FF Full duplex (default) O N Half duplex SW3 TP Port Speed OF F 100Mbps (default) O N 10Mbps SW 4 802.3x function OF F Enable (default) O N Disable SW 5 FX1 port duplex OF F Full duplex mode (defau ...

  • KTI Networks KCD-302 Series - page 27

    -27- 3.1.3 FX Port Duplex Settings SW5 SW6 This settings are used to set the duplex mode of the FX1 port and FX2 port individually . It is recommended to use full duplex mode f or FX con- nection unless its link partner is a fixed half duplex device. Half duplex mode will shorten the connection distance. The following table lists the maximum MMF ca ...

  • KTI Networks KCD-302 Series - page 28

    -28- 3.2 LED Indicators LED DISPLA Y ST A TUS & INTERPRET A TION PWR Power status ON Power on O F F Power off TP LINK TP port link status ON Link up and no traffic O F F Link fault Blink Rx/Tx activities 100M TP port speed status ON 100Mbps O F F 10Mbps F D X TP port duplex status ON Full duplex O F F Half duplex Blink Collisions on half duplex ...

Fabricant KTI Networks Catégorie Network Card

Les documents que nous recevons du fabricant de l'appareilKTI Networks KCD-302 Series peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques KTI Networks
- manuels d’utilisations KCD-302 Series
- fiches produit KTI Networks
- dépliants
- ou étiquettes-énergie KTI Networks KCD-302 Series
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation KTI Networks KCD-302 Series.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation KTI Networks KCD-302 Series, manuels d’entretien, brefs manuels ou manuels de l’utilisateur KTI Networks KCD-302 Series. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit KTI Networks KCD-302 Series.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil KTI Networks KCD-302 Series, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser KTI Networks KCD-302 Series par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs KTI Networks KCD-302 Series.

Le manuel d’utilisation complet KTI Networks, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel KTI Networks KCD-302 Series - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières KTI Networks KCD-302 Series, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lKTI Networks KCD-302 Series qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil KTI Networks KCD-302 Series - qui devraient nous aider dans les premières étapes lors de l'utilisation KTI Networks KCD-302 Series
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de KTI Networks KCD-302 Series
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service KTI Networks KCD-302 Series dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de KTI Networks KCD-302 Series?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec KTI Networks KCD-302 Series, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec KTI Networks KCD-302 Series il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)