    -1- INDUSTRIAL T ri-segment Medi a Converter KCD-302 Series Installation Guide DOC.060301-KCD-302 ...

  • KTI Networks KCD-302 Series - page 2

    -2- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documen- tation may be reproduced in any form or by any means or used to make any directive work (such as translation or transformation) without per- mission from KTI Networks Inc. KTI Networks Inc. reserves the right to revise this documentation and to make changes in content from ...

  • KTI Networks KCD-302 Series - page 3

    -3- The information contained in this document is subject to change without prior notice. Copyright (C) All Rights Reserved. TRADEMARKS Ethernet is a registered trademark of Xerox Corp. FCC NOTICE This device complies with Class B Part 15 the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful inte ...

  • KTI Networks KCD-302 Series - page 4

    -4- T a ble of Contents 1. Introduction ......................................................... 5 1.1 Features ........................................................................................ 7 1.2 Specifications ................................................................................ 8 1.3 Model Specifications ................... ...

  • KTI Networks KCD-302 Series - page 5

    -5- 1. Introduction The industrial tri-segment media converter series provides one 10/100BASE- TX Fast Ethernet port and two 100BASE-FX ports. It supports the connec- tions to three network segments, one UTP and two fiber cables. It serves the network data transfer between any two segments in switching basis. The following figure illustrates a basi ...

  • KTI Networks KCD-302 Series - page 6

    -6- For industrial environment, the converters are designed with the follow- ing enhanced features exceeding that of commercial media converters:  High a nd wide operating T emperature ra nge  W ide operating voltage ra nge for DC power input  Power input interface: Screw terminal block and DC jack for adapter  DIN rail mounting support ...

  • KTI Networks KCD-302 Series - page 7

    -7- 1.1 Features • Support network data transfer at full wire speed • The TP port supports 10Mbps and 100Mbps connections • Auto MDI/MDI-X detection function on the TP (copper) port • Auto-negotiation function on the TP port • Transparent conversion to 802.1Q VLAN tagged packets between any two segments • Far End Fault function on FX (f ...

  • KTI Networks KCD-302 Series - page 8

    -8- 1.2 Specifications This figure shows the important components of the converter: ...

  • KTI Networks KCD-302 Series - page 9

    -9- T wisted-Pair Interfa ce (TP Por t, or called copper Por t) Connector Shielded RJ-45 Pin Assignments Auto MDI/MDI-X detection Signal Compliance IEEE 802.3 10BASE-T , 802.3u 100BASE-TX Data Speed 10Mbps or 100Mbps Duplex Mode Half-duplex or Full-duplex Configuration Auto-negotiation capable and optional forced manual settings Ca ble T ypes 10Mbp ...

  • KTI Networks KCD-302 Series - page 10

    -10- Configuration Setting Switches (SW) NO. FUNCTION SETTINGS SW1 TP Port mode O FF Auto-negotiation (default) O N Forced mode SW2 TP Port Duplex O F F Full duplex (default) O N Half duplex SW3 TP Port Speed O FF 100Mbps (default) ON 10Mbps SW4 802.3x function O FF Enable (default) O N Disable SW5 FX1 port duplex O F F Full duplex mode (default) O ...

  • KTI Networks KCD-302 Series - page 11

    -11- DC Power Input Interface Screw-type terminal block (2 sets for power wire cascading) DC Jack ( -D 6.3mm / + D 2.0mm) Operating Input V oltages +7V ~ +30V(+5%) Power c on s um ption 2.7W max. @7.5VDC input 2.9W max. @24VDC input 3.0W max. @+30VDC input Basic Information MAC Addresses Entries 1 K Forwarding Throughput Full wire speed at 100M ful ...

  • KTI Networks KCD-302 Series - page 12

    -12- Certificate F C C Part 15 Class B CE/EMC EMI EN50081-1 Class B EMS EN55024 CE/L V D Safe ty E N 60950 EN 50081-1/1992 : EN55022:1994/A1:1995/A2:1997 CISPR Class B EN61000-3-2:2000 Device <75W EN61000-3-3:1995/A1:2001 Clause 5 EN 55024:1998/A1:2001 IEC 61000-4-2:1995 ESD T est IEC 61000-4-3:1995 RS T est IEC 61000-4-4:1995 EFT/BURST T est IE ...

  • KTI Networks KCD-302 Series - page 13

    -13- 1.3 Model Specifications The media converter series provides the following fiber options: KCD-302-xxx WaveL. Reference Operating Model Ext. FX Connectors (nm) Fiber Distance Te mperature -2T FX1 : ST MMF 1310 2 k m -10 ~ 70 o C FX2 : ST MMF 1310 2 km -10 ~ 70 o C -2C FX1 : SC MMF 1310 2 k m -10 ~ 70 o C FX2 : SC MMF 1310 2 k m -10 ~ 70 o C -2C ...

  • KTI Networks KCD-302 Series - page 14

    -14- 1.4 Special Functions Auto MDI/MDI-X Function This function allows the TP port to auto-detect the twisted-pair signals and adapts itself to form a valid MDI to MDI-X connection with the remote connected device automatically . Auto-negotiation Function When TP port is set on Auto-negotiation mode (SW1:ON), it is featured with auto-negotiation f ...

  • KTI Networks KCD-302 Series - page 15

    -15- 2. Installation 2.1 Unpacking Check that the following components have been included: • Information CD • The product unit • DIN-rail mounting bracket If any item is found missing or damaged, please contact your local reseller for replacement. The following are available optional accessories: • Panel Mounting Bracket The bracket is used ...

  • KTI Networks KCD-302 Series - page 16

    -16- 2.2 DIN-Rail Mounting In the product package, a DIN-rail bracket is provided for mounting the converter in a industrial DIN-rail enclosure. The steps to mount the device onto a DIN-rail are: 1. Clamp the bracket into the rear of the device. Align the bracket with the rear face of the device and screw it onto the device unit. ...

  • KTI Networks KCD-302 Series - page 17

    -17- 2. Unscrew and loose the mounting clamp plate of the bracket. Mount the bracket with the device onto the DIN rail. 5. Screw the clamp with the bracket and make sure the device is properly fixed on the DIN rail. ...

  • KTI Networks KCD-302 Series - page 18

    -18- M ake sure that there are proper heat dissi pation from a nd a dequate ven- tilation around the device. The final mechanical dimensions after installing DIN rail mounting bracket are: ...

  • KTI Networks KCD-302 Series - page 19

    -19- 2.3 Mounting on a Panel Surface An optional mounting bracket, as shown below is also available for mount- ing the device on a panel surface such as a wall, a wood board, or a metal plate in an industrial enclosure. T o mount the device on a pa nel surface, the ste ps are: 1. Clamp the bracket into the device and align the bracket with the bott ...

  • KTI Networks KCD-302 Series - page 20

    -20- 2. Mount a nd screw the device on the target surface. The final dimen- sion after bracket installation is also shown below: Make sure that there are proper heat dissipation from and adequate ven- tilation around the device. Do not place heavy objects on the device. ...

  • KTI Networks KCD-302 Series - page 21

    -21- 2.4 Applying Power The product provide two types of power interfaces, terminal block and DC power ja ck for receiving DC power input from external power supply . DC Power Input Specification Operating V oltage + 7 ~ +30VDC Power Consumption Max. 3.0W @30VDC DC Power T erminal Block Connectors Screw-type T erminal block (2 sets) Pin Assignments ...

  • KTI Networks KCD-302 Series - page 22

    -22- DC2 + a nd DC2 - ca n be installed with a nother power-pair f or delivering the main power input to next converter in a ca sca ding way . Note: Only up to four device units can be cascaded to receive power from one main power input source. DC Power Jack Connector: Jack D 6.3mm D 2.0mm AC Power Adapters: Optional commercial rated adapters are a ...

  • KTI Networks KCD-302 Series - page 23

    -23- 2.5 Making TP Port Connection TP port is featured to support connection to : • Auto-negotiation devices • Auto-negotiation incapable 10BASE-T devices • Auto-negotiation incapable 100BASE-TX devices Network Cables 10BASE-T : 2-pair UTP Cat. 3,4,5 , EIA/TIA-568B 100-ohm STP 100BASE-TX: 2-pair UTP Cat. 5, EIA/TIA-568B 100-ohm STP Link dista ...

  • KTI Networks KCD-302 Series - page 24

    -24- 2.6 Ma king FX Port Connection s FX1 port and FX2 port operate on 100Mbps and full duplex (factory default). A variety of fiber options is provided as listed in Section 1.3. Network Cables Multimode (MMF) - 50/125, 62.5/125 Single mode (SMF) - 9/125 ...

  • KTI Networks KCD-302 Series - page 25

    -25- 3 Configuration Switches & LED Indicators The following figure shows the locations of the configuration switches and LED indicators: Refer to the following sections for the related functions. ...

  • KTI Networks KCD-302 Series - page 26

    -26- 3.1 Configuration Switche s SW FUNCTION SETTING & ST A TE SW 1 TP Port mode OFF Auto-negotiation (default) O N Forced mode SW2 TP Port Duplex O FF Full duplex (default) O N Half duplex SW3 TP Port Speed OF F 100Mbps (default) O N 10Mbps SW 4 802.3x function OF F Enable (default) O N Disable SW 5 FX1 port duplex OF F Full duplex mode (defau ...

  • KTI Networks KCD-302 Series - page 27

    -27- 3.1.3 FX Port Duplex Settings SW5 SW6 This settings are used to set the duplex mode of the FX1 port and FX2 port individually . It is recommended to use full duplex mode f or FX con- nection unless its link partner is a fixed half duplex device. Half duplex mode will shorten the connection distance. The following table lists the maximum MMF ca ...

  • KTI Networks KCD-302 Series - page 28

    -28- 3.2 LED Indicators LED DISPLA Y ST A TUS & INTERPRET A TION PWR Power status ON Power on O F F Power off TP LINK TP port link status ON Link up and no traffic O F F Link fault Blink Rx/Tx activities 100M TP port speed status ON 100Mbps O F F 10Mbps F D X TP port duplex status ON Full duplex O F F Half duplex Blink Collisions on half duplex ...

Manufacturer KTI Networks Category Network Card

Documents that we receive from a manufacturer of a KTI Networks KCD-302 Series can be divided into several groups. They are, among others:
- KTI Networks technical drawings
- KCD-302 Series manuals
- KTI Networks product data sheets
- information booklets
- or energy labels KTI Networks KCD-302 Series
All of them are important, but the most important information from the point of view of use of the device are in the user manual KTI Networks KCD-302 Series.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals KTI Networks KCD-302 Series, service manual, brief instructions and user manuals KTI Networks KCD-302 Series. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product KTI Networks KCD-302 Series.

A complete manual for the device KTI Networks KCD-302 Series, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use KTI Networks KCD-302 Series by users. Manuals are usually written by a technical writer, but in a language understandable to all users of KTI Networks KCD-302 Series.

A complete KTI Networks manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual KTI Networks KCD-302 Series - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the KTI Networks KCD-302 Series, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the KTI Networks KCD-302 Series, that we can find in the current document
3. Tips how to use the basic functions of the device KTI Networks KCD-302 Series - which should help us in our first steps of using KTI Networks KCD-302 Series
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with KTI Networks KCD-302 Series
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of KTI Networks KCD-302 Series in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning KTI Networks KCD-302 Series?

Use the form below

If you did not solve your problem by using a manual KTI Networks KCD-302 Series, ask a question using the form below. If a user had a similar problem with KTI Networks KCD-302 Series it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)