Manuel d’utilisation Greenheck Fan 474051

12 pages 1.19 mb
Télécharger

Aller à la page of 12

Summary
  • Greenheck Fan 474051 - page 1

    1 Fiberglass Centrifugal Fan Installation, Operation and Maintenance Manual Please read and save these instructions. Read car efully before attempting to assemble, install, operate or maintain the product described. Pr otect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury ...

  • Greenheck Fan 474051 - page 2

    2 Model BCSW-FRP Fans are pr otected against damage during shipment. If the unit cannot be installed and operated immediately , precautions need to be taken to pr event deterioration of the unit during storage. The user assumes responsibility of the fan and accessories while in storage. The manufacturer will not be r esponsible for damage during st ...

  • Greenheck Fan 474051 - page 3

    3 Model BCSW-FRP CAUTION When installing a fan, ensure the pr oper protective devices are used to pr otect personnel from moving parts and other hazards. A complete line of protective accessories ar e available from Greenheck including belt guar ds, shaft guards, and electrical disconnects. Electrical Disconnects All fan motors should have disconne ...

  • Greenheck Fan 474051 - page 4

    4 Model BCSW-FRP Ducted Outlet Installations Discharge Duct Turns - Duct turns located near the fan discharge should always be in the direction of the fan rotation. Fan performance is reduced when duct turns are made immediately off the fan discharge. T o achieve cataloged fan performance there should be at least three equivalent duct diameters of ...

  • Greenheck Fan 474051 - page 5

    5 Model BCSW-FRP Bases (Foundation and Isolation) In order to assur e continued alignment, a high strength, non-shrink epoxy gr out is recommended to provide the desir ed mechanical properties for support of the fan. This type of support ensures the appropriate transmission of static and dynamic loads to the equipment foundation. T o eliminate vibr ...

  • Greenheck Fan 474051 - page 6

    6 Model BCSW-FRP Radial Gap, Overlap and Wheel Alignment Efficient fan performance can be maintained by having the correct radial gap, overlap and wheel alignment. These items should be checked after the fan has been in operation for 24 hours and before start-up after the unit has been serviced. Radial Gap is adjusted by loosening the housing bolts ...

  • Greenheck Fan 474051 - page 7

    7 Model BCSW-FRP Flexible Couplings (Arr . 8 Only) Check for misalignment between the coupling halves. Parallel and angular misalignment and separation gap are illustrated below . Refer to coupling manufacturer’ s installation instructions for allowable misalignment and separation gap tolerances. When correcting for misalignment using shims, the ...

  • Greenheck Fan 474051 - page 8

    8 Model BCSW-FRP Vibration Excessive vibration is the most frequent pr oblem experienced during initial start-up. Left unchecked, excessive vibration can cause a multitude of problems, including structural and/or component failure. Many of these conditions can be discovered by car eful observation. Refer to the troubleshooting section of this manua ...

  • Greenheck Fan 474051 - page 9

    9 Model BCSW-FRP Routine Maintenance Once the unit has been put into operation, a routine maintenance schedule should be set up to accomplish the following: 1. Lubrication of bearings and motor (see below). 2. Wheel, housing, bolts and set screws on the entire fan should be checked for tightness. 3. Any dirt accumulation on the wheel or in the hous ...

  • Greenheck Fan 474051 - page 10

    10 Model BCSW-FRP Parts List Housing Wheel Gasket Backplate Shaft Guard Shaft Seal Shaft Belt Guard Belt Guard Cover Belt Motor Pulley Shaft Pulley Adjustable Motor Slide Base Bearings Inlet Cone Outlet Flange Base/Housing Foot Angle (4) Access Door with Gasket V-Belt Drives V -belt drives must be checked on a regular basis for wear , tension, alig ...

  • Greenheck Fan 474051 - page 11

    11 Model BCSW-FRP Problem Cause Corrective Action Excessive Noise Wheel rubbing (inlet) Adjust wheel. Tighten wheel hub or bearing collars on shaft. V -belt drive Tighten Sheaves on motor/fan shaft. Adjust belt tension. Align sheaves properly (see V -Belt Drives section). Replace worn belts or sheaves. Bearings Replace defective bearing(s). Lubrica ...

  • Greenheck Fan 474051 - page 12

    12 474051 • BCSW-FRP , Rev . 1, November 2010 Copyright 2010 © Greenheck Fan Corporation ® Phone:(715)359-6171•Fax:(715)355-2399•E-mail:gfcinfo@greenheck.com• W ebsite: www .greenheck.com AMCA Publication 410-96, Safety Practices for Users and Installers of Industrial and Commercial Fans, pr ovides additio ...

Fabricant Greenheck Fan Catégorie Fan

Les documents que nous recevons du fabricant de l'appareilGreenheck Fan 474051 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Greenheck Fan
- manuels d’utilisations 474051
- fiches produit Greenheck Fan
- dépliants
- ou étiquettes-énergie Greenheck Fan 474051
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Greenheck Fan 474051.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Greenheck Fan 474051, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Greenheck Fan 474051. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Greenheck Fan 474051.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Greenheck Fan 474051, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Greenheck Fan 474051 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Greenheck Fan 474051.

Le manuel d’utilisation complet Greenheck Fan, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Greenheck Fan 474051 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Greenheck Fan 474051, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lGreenheck Fan 474051 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Greenheck Fan 474051 - qui devraient nous aider dans les premières étapes lors de l'utilisation Greenheck Fan 474051
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Greenheck Fan 474051
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Greenheck Fan 474051 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Greenheck Fan 474051?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Greenheck Fan 474051, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Greenheck Fan 474051 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)