    1 Fiberglass Centrifugal Fan Installation, Operation and Maintenance Manual Please read and save these instructions. Read car efully before attempting to assemble, install, operate or maintain the product described. Pr otect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury ...

  • Greenheck Fan 474051 - page 2

    2 Model BCSW-FRP Fans are pr otected against damage during shipment. If the unit cannot be installed and operated immediately , precautions need to be taken to pr event deterioration of the unit during storage. The user assumes responsibility of the fan and accessories while in storage. The manufacturer will not be r esponsible for damage during st ...

  • Greenheck Fan 474051 - page 3

    3 Model BCSW-FRP CAUTION When installing a fan, ensure the pr oper protective devices are used to pr otect personnel from moving parts and other hazards. A complete line of protective accessories ar e available from Greenheck including belt guar ds, shaft guards, and electrical disconnects. Electrical Disconnects All fan motors should have disconne ...

  • Greenheck Fan 474051 - page 4

    4 Model BCSW-FRP Ducted Outlet Installations Discharge Duct Turns - Duct turns located near the fan discharge should always be in the direction of the fan rotation. Fan performance is reduced when duct turns are made immediately off the fan discharge. T o achieve cataloged fan performance there should be at least three equivalent duct diameters of ...

  • Greenheck Fan 474051 - page 5

    5 Model BCSW-FRP Bases (Foundation and Isolation) In order to assur e continued alignment, a high strength, non-shrink epoxy gr out is recommended to provide the desir ed mechanical properties for support of the fan. This type of support ensures the appropriate transmission of static and dynamic loads to the equipment foundation. T o eliminate vibr ...

  • Greenheck Fan 474051 - page 6

    6 Model BCSW-FRP Radial Gap, Overlap and Wheel Alignment Efficient fan performance can be maintained by having the correct radial gap, overlap and wheel alignment. These items should be checked after the fan has been in operation for 24 hours and before start-up after the unit has been serviced. Radial Gap is adjusted by loosening the housing bolts ...

  • Greenheck Fan 474051 - page 7

    7 Model BCSW-FRP Flexible Couplings (Arr . 8 Only) Check for misalignment between the coupling halves. Parallel and angular misalignment and separation gap are illustrated below . Refer to coupling manufacturer’ s installation instructions for allowable misalignment and separation gap tolerances. When correcting for misalignment using shims, the ...

  • Greenheck Fan 474051 - page 8

    8 Model BCSW-FRP Vibration Excessive vibration is the most frequent pr oblem experienced during initial start-up. Left unchecked, excessive vibration can cause a multitude of problems, including structural and/or component failure. Many of these conditions can be discovered by car eful observation. Refer to the troubleshooting section of this manua ...

  • Greenheck Fan 474051 - page 9

    9 Model BCSW-FRP Routine Maintenance Once the unit has been put into operation, a routine maintenance schedule should be set up to accomplish the following: 1. Lubrication of bearings and motor (see below). 2. Wheel, housing, bolts and set screws on the entire fan should be checked for tightness. 3. Any dirt accumulation on the wheel or in the hous ...

  • Greenheck Fan 474051 - page 10

    10 Model BCSW-FRP Parts List Housing Wheel Gasket Backplate Shaft Guard Shaft Seal Shaft Belt Guard Belt Guard Cover Belt Motor Pulley Shaft Pulley Adjustable Motor Slide Base Bearings Inlet Cone Outlet Flange Base/Housing Foot Angle (4) Access Door with Gasket V-Belt Drives V -belt drives must be checked on a regular basis for wear , tension, alig ...

  • Greenheck Fan 474051 - page 11

    11 Model BCSW-FRP Problem Cause Corrective Action Excessive Noise Wheel rubbing (inlet) Adjust wheel. Tighten wheel hub or bearing collars on shaft. V -belt drive Tighten Sheaves on motor/fan shaft. Adjust belt tension. Align sheaves properly (see V -Belt Drives section). Replace worn belts or sheaves. Bearings Replace defective bearing(s). Lubrica ...

  • Greenheck Fan 474051 - page 12

    12 474051 • BCSW-FRP , Rev . 1, November 2010 Copyright 2010 © Greenheck Fan Corporation ® Phone:(715)359-6171•Fax:(715)355-2399•E-mail:gfcinfo@greenheck.com• W ebsite: www .greenheck.com AMCA Publication 410-96, Safety Practices for Users and Installers of Industrial and Commercial Fans, pr ovides additio ...

メーカー Greenheck Fan カテゴリー Fan

Greenheck Fan 474051のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 474051の取扱説明書
- Greenheck Fanの製品カード
- パンフレット
- またはGreenheck Fan 474051の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Greenheck Fan 474051の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Greenheck Fan 474051の取り付け説明書、サービスマニュアル、簡易説明書、またはGreenheck Fan 474051のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Greenheck Fan 474051の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Greenheck Fan 474051デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGreenheck Fan 474051を使用するのを助ける技術的文書のことです。説明書は通常、全てのGreenheck Fan 474051ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Greenheck Fanの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Greenheck Fan 474051の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGreenheck Fan 474051の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Greenheck Fan 474051に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Greenheck Fan 474051デバイスの基本機能を使うにあたってのヒント。 Greenheck Fan 474051のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Greenheck Fan 474051に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGreenheck Fan 474051のメーカー/サービスへの連絡先に関する情報。

Greenheck Fan 474051についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGreenheck Fan 474051の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGreenheck Fan 474051で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)