Manuel d’utilisation Agilent Technologies 34970A

20 pages 0.31 mb
Télécharger

Aller à la page of 20

Summary
  • Agilent Technologies 34970A - page 1

    4XLFN5H IHUHQF H*XLGH SCPI Co mmand Summa ry The following conventions are used for SCPI command syntax for remote interface programming: • Square brackets ( [ ] ) indicate o ptional keywords o r parameters. • Braces ( { } ) enclose parameter choices with in a command string. • Triangle brackets ( < > ) enclose parameters for whic ...

  • Agilent Technologies 34970A - page 2

    Scan Measurement Commands ( see page 226 in the User’s Gu ide ) MEASure :TEMPerature? { TCoup le |RTD|FRTD|THERmi stor|DEF} ,{< type >|DEF}[,1[,{< resolution >|MIN|MAX|DEF}]] ,( @ < scan_list >) :VOLTage:DC? [{< range >| AUTO |MIN| MAX|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_list >) :VOLTage:AC? [{< ...

  • Agilent Technologies 34970A - page 3

    Scan Configuration Commands ( see page 226 in the User’s Gu ide ) ROUTe :SCAN ( @ < scan_list >) :SCAN? :SCAN:SIZE? TRIGger : SOU Rce {B U S | IMMediate |EXTernal|ALA Rm1|ALARm2|ALARm3|ALARm4 |TIMer} :SOURce? TRIGger :TIMer {< seconds >| MIN |MAX} :TIMer? TRIGger :COUNt {< count >| MIN |MAX|INFi nity} :COUNt? ROUTe :CHANnel:DELa ...

  • Agilent Technologies 34970A - page 4

    Scanning With an External Instrument ( see page 239 in the User’s Gu ide ) ROUTe :SCAN ( @ < scan_list >) :SCAN? :SCAN:SIZE? TRIGger :SOURce {BUS|IMMediate|EXT ernal| TIMer } :SOURce? TRIGger :TIMer {< seconds >| MIN |MAX} :TIMer? TRIGger :COUNt {< count >|MIN|MAX| INFi nity } :COUNt? ROUTe :CHANnel:DELay < seconds >[,( @ ...

  • Agilent Technologies 34970A - page 5

    Temperature Configuration Commands ( see page 219 in the User’s Gu ide ) CONFigure :TEMPerature { TCoupl e |RTD|FRTD|THERmis tor|DEF} ,{< type >|DEF}[,1[,{< resolution >|MIN|MAX|DEF}]] ,( @ < scan_list >) CONFigure? [( @ < ch_lis t >)] UNIT :TEMPerature { C |F|K}[,( @ < ch_list >)] :TEMPerature? [( @ < ch_list > ...

  • Agilent Technologies 34970A - page 6

    Voltage Configuration Commands ( see page 223 in the User’s Gu ide ) CONFigure :VOLTage:DC [{< range >| AUTO |MIN|M AX|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_list >) CONFigure? [( @ < ch_lis t >)] [SENSe:] VOLTage:DC:RANGe {< range >|MIN|MAX}[, ( @ < ch_list >)] VOLTage:DC:RANGe? [{( @ < ch_list &g ...

  • Agilent Technologies 34970A - page 7

    Resistance Configuration Commands ( see page 224 in the User’s Gu ide ) CONFigure :RESistance [{< range >| AUTO |MIN|M AX|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_list >) CONFigure? [( @ < ch_lis t >)] [SENSe:] RESistance:RANGe {< range >|MIN|MAX}[, ( @ < ch_list >)] RESistance:RANGe? [{( @ < ch_list ...

  • Agilent Technologies 34970A - page 8

    Current Configuration Commands ( see page 224 in the User’s Gu ide ) Valid only on channels 21 and 22 on the 34901A mul tiplexer module. CONFigure :CURRent:DC [{< range >| AUTO |MIN|M AX|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_list >) CONFigure? [( @ < ch_lis t >)] [SENSe:] CURRent:DC:RANGe {< range >|MIN|MA ...

  • Agilent Technologies 34970A - page 9

    Frequency a nd Period Configuration Commands ( see page 214 in the User’s Gu ide ) CONFigure :FREQuency [{< range >| AUTO |MIN|MA X|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_list >) CONFigure? [( @ < ch_lis t >)] [SENSe:] FREQuency:VOLTage:RANGe {< range >|MIN|MAX}[,( @ < ch_list >) ] FREQuency:VOLTage:R ...

  • Agilent Technologies 34970A - page 10

    Mx+B Scalin g Commands ( see page 244 in the User’s Gu ide ) CALCulate :SCALe:GAIN < gain >[ ,( @ < ch_list >)] :SCALe:GAIN? [( @ < ch_list >)] :SCALe:OFFSet < offset >[,( @ < ch_list >)] :SCALe:OFFSet? [( @ < ch_list >)] :SCALe:UNIT < quot ed_ strin g >[,( @ < ch_ list >)] :SCALe:UNIT? [( @ < ch ...

  • Agilent Technologies 34970A - page 11

    Digital Input Commands ( see page 255 in the User’s Gu ide ) Ch 01 DIO (L SB) Ch 0 2 DIO (MSB ) Ch 03 Totalizer Ch 04 DAC Ch 05 DAC CONFigure:DIGital:BYTE ( @ < scan_list >) CONFigure? [( @ < ch_lis t >)] [SENSe:]DIGital:DATA:{ BYT E |WORD}? [( @ < ch_lis t >)] Totalizer Commands ( see page 256 in the User’s Gu ide ) Ch 01 DIO ...

  • Agilent Technologies 34970A - page 12

    Switch Control Commands ( see page 259 in the User’s Gu ide ) ROUTe :CLOSe ( @ < ch_list >) :CLOSe:EXCLusive ( @ < ch_list >) :CLOSe? ( @ < ch_lis t >) ROUTe :OPEN ( @ < ch_list >) :OPEN? ( @ < ch_list >) ROUTe:DONE? SYSTem:CPON {100|200|300|ALL } Scan Triggering Commands ( see page 228 in the User’s Gu ide ) TRIGg ...

  • Agilent Technologies 34970A - page 13

    System-Related Commands ( see page 264 in the User’s Gu ide ) SYSTem :DATE < yyyy > , < mm > ,< dd > :DATE? :TIME < hh >,< mm >,< ss.sss > :TIME? FORMat :READing:TIME:TYPE {ABSolu te| RELative } :READing:TIME:TYPE? *IDN? SYSTem:CTYPe? {100|200|300} DIAGnostic :POKE:SLOT:DATA {100|200|3 00}, < quoted_string & ...

  • Agilent Technologies 34970A - page 14

    Status System Commands ( see page 286 in the User’s Gu ide ) *STB? *SRE < enable _value > *SRE? STATus :QUEStionable:CONDition? :QUEStionable[:EVENt]? :QUEStionable:ENABle < ena ble_value > :QUEStionable:ENABle? *ESR? *ESE < enable _value > *ESE? STATus :ALARm:CONDition? :ALARm[:EVENt]? :ALARm:ENABle < en able_value > :ALA ...

  • Agilent Technologies 34970A - page 15

    Service-Related Commands ( see page 294 in the User’s Gu ide ) INSTrument :DMM {OFF|ON} :DMM? :DMM:INSTalled? DIAGnostic :DMM:CYCLes? :DMM:CYCLes:CLEar (1|2|3} DIAGnostic :RELay:CYCLes? [( @ < ch_list >)] :RELay:CYCLes:CLEar [( @ < ch_list >)] *RST SYSTem:PRESet SYSTem:CPON {100|200|300|ALL } SYSTem:VERSion? *TST? IEEE 488.2 Co mmon C ...

  • Agilent Technologies 34970A - page 16

    Agilent 34901A 20-Channel Multiplexer ( see page 164 in the User’s Gu ide ) Agilent 34902A 16-Channel Multiplexer ( see page 166 in the User’s Gu ide ) 16 ...

  • Agilent Technologies 34970A - page 17

    Agilent 34903A 20-Channel Act uator ( see page 168 in the User’s Gu ide ) Agilent 34904A 4x8 Matrix ( see page 170 in the User’s Gu ide ) 17 ...

  • Agilent Technologies 34970A - page 18

    Agilent 34905A/6A Dual 4- Channel RF Multiplexers ( see page 172 in the User’s Gu ide ) Agilent 34908A 40-Channel Single-Ended Mul tiplexer ( see page 174 in the User’s Gu ide ) 18 ...

  • Agilent Technologies 34970A - page 19

    Agilent 34907A Mult ifunction Module ( see page 176 in the User’s Gu ide ) 19 ...

  • Agilent Technologies 34970A - page 20

    Factory Reset State The table below shows the state of the instrument after a FACTORY RESET from the Sto/Rcl menu or *RST command from the remote interface. Measurement Configurati on Fu ncti on Range Res olu tio n Inte gration Time Input Re sistance Channel D elay Totalizer Rese t Mode Tota lize r Edge De tect Scanning Oper atio ns Scan L ist Read ...

Fabricant Agilent Technologies Catégorie Switch

Les documents que nous recevons du fabricant de l'appareilAgilent Technologies 34970A peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Agilent Technologies
- manuels d’utilisations 34970A
- fiches produit Agilent Technologies
- dépliants
- ou étiquettes-énergie Agilent Technologies 34970A
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Agilent Technologies 34970A.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Agilent Technologies 34970A, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Agilent Technologies 34970A. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Agilent Technologies 34970A.

Manuel d’utilisation complet de l’appareil Agilent Technologies 34970A, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Agilent Technologies 34970A par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Agilent Technologies 34970A.

Le manuel d’utilisation complet Agilent Technologies, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Agilent Technologies 34970A - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Agilent Technologies 34970A, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAgilent Technologies 34970A qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Agilent Technologies 34970A - qui devraient nous aider dans les premières étapes lors de l'utilisation Agilent Technologies 34970A
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Agilent Technologies 34970A
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Agilent Technologies 34970A dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Agilent Technologies 34970A?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Agilent Technologies 34970A, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Agilent Technologies 34970A il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)