    F OR B409 D OUBLE W ALL T ANK S UMP WITH REINFORCED BOTT OM S. Bravo Systems, Inc. 2929 V ail A ve. - Commerce, CA 90040 (323) 888-4133 - F AX: (323) 888-4123 www .SBravo.com ii-B409-DW-10A INST ALLA TION INSTRUCTIONS Written by: Jonathan Smith ...

  • Bravo View B409 - page 2

    READ THESE INSTRUCTIONS - KEEP FOR FUTURE REFERENCE T ABLE OF CONTENTS DRY FITTING SUMP & EQUIPMENT ................................ p. 4 A) Installing & Securing.......................................................... p. 5 Install & T est Penetration Fittings...................................... p. 5 (A.4) B) Mantadory Air Integrity ...

  • Bravo View B409 - page 3

    3 ii-B409-DW-10A It is REQUIRED to visually check the V acuum gauge on each and every Bravo Systems Double W all product and write on its F AX report V acuum level , name of observer , and date for every DoubleW all Sump. A) There is a failure to comply with the Required written report guidelines as stated above. B) Double W all Products are DOUBLE ...

  • Bravo View B409 - page 4

    4 ii-B409-DW-10A EQUIPMENT DR Y -FIT - BEFORE INST ALLING PENETRA TION FITTINGS - BEFORE CUTTING OPEN SUMP INTERSTICE DR Y -FIT YOUR SUMP PIECES AND INTERNAL EQUIPMENT . PLAN YOUR INST ALLA TION AND MAKE SURE EVER YTHING FITS, AND WILL FIT LA TER DURING INST ALLA TION. Recommended T ools (NOT PROVIDED) Power/air Sanders. Acetone to clean up tools/a ...

  • Bravo View B409 - page 5

    A.1 - Visually inspect the p arts provided by Bravo Systems for In-transit damage and/or missing part s. Continue to keep the Sump clean of debris throughout your installation process. A.2 - Set your B409 Piping Sump where it must be per site plans. Secure the Sump to avoid movement while penetrating. A.3 - Mark where you will penetrate the Base/T ...

  • Bravo View B409 - page 6

    B - MANDA T OR Y AIR INTEGRITY TEST B.1 - Use test assembly and pressure sump to no more than 4 PSI. Close off with ball valve and resume other work. Allow 1 Hour before recording pressure. F IELD A IR I NTEGRITY I NSPECTION T EST : Hold pressure for a minimum of 1 hour for a Field Integrity Inspection T est. The T ank Sump P ASSES the integrity te ...

  • Bravo View B409 - page 7

    C - V ACUUM / HYDROST A TIC FILLING F IELD A IR I NTEGRITY I NSPECTION T EST : YOUR PRODUCT W ARRANTY WILL BE VOID IF YOU DO NOT Hold pressure for a minimum of 1 hour for a Field Integrity Inspection T est. After passing the pressure test, it is HIGHL Y RECOMMENDED that the 4 PSI is maintained for as long as possible, up until the time of backfill. ...

  • Bravo View B409 - page 8

    8 C.3 - Close off ball valve completely and prime the open ended 36” length of clear tubing with provided Interstitial Fluid. Use a liquid funnel. Filling Bravo Systems Double W all Product s with Brine (saline) solution will void the product warranty . Y ou must use only Bravo-Supplied Interstitial Fluid , p art # IMF-1GAL C.4 - Af ter filling t ...

  • Bravo View B409 - page 9

    D) ADV ANCED LEAK DETECTION PROCEDURE A Bravo Systems Exclusive detection method D.1 - Clear debris from the top open area of the DoubleW all Product and ensure that the interior walls are clean of debris and visible. D.2 - Apply V acuum to the sealed interstitial sp ace with the V enturi V acuum Assembly , and generate 20”-30” of vacuum for a ...

  • Bravo View B409 - page 10

    Even though Bravo DoubleW all product corners and edges are thicker than the rest of the Containment sump, These areas recieve the most supceptable to physical damage by Installing Contractors. Y ou would do well to be extremely careful with these DoubleW all products while storing, moving, transporting and Installing these critical environment al ...

  • Bravo View B409 - page 11

    E - CONNECTING T O MANOMETER E.1 - At this point, after the ALDP test, the interstice should still be holding vacuum. Maintain 20” of V acuum and slowly open ball valve to let fluid into the interstice until it exits the venturi assembly . Visually check whether the fluid level reaches the top of the interstitial sp ace. E.2 - Cut the barb & ...

  • Bravo View B409 - page 12

    12 ii-B409-DW-10A G - Concrete and Backfill Guidelines. T o ensure that no immediate or future damage is done to your Bravo T ank Sump Reducer components, make sure that your manhole skirt DOES NOT T OUCH OR REST ON THE T ANK SUMP SHOULDER. The Manhole Skirt should be kept at minimum of 4” away from the tank sump shoulder . Follow the manhole man ...

Fabricant Bravo View Catégorie Water Pump

Les documents que nous recevons du fabricant de l'appareilBravo View B409 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Bravo View
- manuels d’utilisations B409
- fiches produit Bravo View
- dépliants
- ou étiquettes-énergie Bravo View B409
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Bravo View B409.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Bravo View B409, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Bravo View B409. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Bravo View B409.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Bravo View B409, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Bravo View B409 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Bravo View B409.

Le manuel d’utilisation complet Bravo View, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Bravo View B409 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Bravo View B409, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lBravo View B409 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Bravo View B409 - qui devraient nous aider dans les premières étapes lors de l'utilisation Bravo View B409
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Bravo View B409
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Bravo View B409 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Bravo View B409?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Bravo View B409, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Bravo View B409 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)