    F OR B409 D OUBLE W ALL T ANK S UMP WITH REINFORCED BOTT OM S. Bravo Systems, Inc. 2929 V ail A ve. - Commerce, CA 90040 (323) 888-4133 - F AX: (323) 888-4123 www .SBravo.com ii-B409-DW-10A INST ALLA TION INSTRUCTIONS Written by: Jonathan Smith ...

  • Bravo View B409 - page 2

    READ THESE INSTRUCTIONS - KEEP FOR FUTURE REFERENCE T ABLE OF CONTENTS DRY FITTING SUMP & EQUIPMENT ................................ p. 4 A) Installing & Securing.......................................................... p. 5 Install & T est Penetration Fittings...................................... p. 5 (A.4) B) Mantadory Air Integrity ...

  • Bravo View B409 - page 3

    3 ii-B409-DW-10A It is REQUIRED to visually check the V acuum gauge on each and every Bravo Systems Double W all product and write on its F AX report V acuum level , name of observer , and date for every DoubleW all Sump. A) There is a failure to comply with the Required written report guidelines as stated above. B) Double W all Products are DOUBLE ...

  • Bravo View B409 - page 4

    4 ii-B409-DW-10A EQUIPMENT DR Y -FIT - BEFORE INST ALLING PENETRA TION FITTINGS - BEFORE CUTTING OPEN SUMP INTERSTICE DR Y -FIT YOUR SUMP PIECES AND INTERNAL EQUIPMENT . PLAN YOUR INST ALLA TION AND MAKE SURE EVER YTHING FITS, AND WILL FIT LA TER DURING INST ALLA TION. Recommended T ools (NOT PROVIDED) Power/air Sanders. Acetone to clean up tools/a ...

  • Bravo View B409 - page 5

    A.1 - Visually inspect the p arts provided by Bravo Systems for In-transit damage and/or missing part s. Continue to keep the Sump clean of debris throughout your installation process. A.2 - Set your B409 Piping Sump where it must be per site plans. Secure the Sump to avoid movement while penetrating. A.3 - Mark where you will penetrate the Base/T ...

  • Bravo View B409 - page 6

    B - MANDA T OR Y AIR INTEGRITY TEST B.1 - Use test assembly and pressure sump to no more than 4 PSI. Close off with ball valve and resume other work. Allow 1 Hour before recording pressure. F IELD A IR I NTEGRITY I NSPECTION T EST : Hold pressure for a minimum of 1 hour for a Field Integrity Inspection T est. The T ank Sump P ASSES the integrity te ...

  • Bravo View B409 - page 7

    C - V ACUUM / HYDROST A TIC FILLING F IELD A IR I NTEGRITY I NSPECTION T EST : YOUR PRODUCT W ARRANTY WILL BE VOID IF YOU DO NOT Hold pressure for a minimum of 1 hour for a Field Integrity Inspection T est. After passing the pressure test, it is HIGHL Y RECOMMENDED that the 4 PSI is maintained for as long as possible, up until the time of backfill. ...

  • Bravo View B409 - page 8

    8 C.3 - Close off ball valve completely and prime the open ended 36” length of clear tubing with provided Interstitial Fluid. Use a liquid funnel. Filling Bravo Systems Double W all Product s with Brine (saline) solution will void the product warranty . Y ou must use only Bravo-Supplied Interstitial Fluid , p art # IMF-1GAL C.4 - Af ter filling t ...

  • Bravo View B409 - page 9

    D) ADV ANCED LEAK DETECTION PROCEDURE A Bravo Systems Exclusive detection method D.1 - Clear debris from the top open area of the DoubleW all Product and ensure that the interior walls are clean of debris and visible. D.2 - Apply V acuum to the sealed interstitial sp ace with the V enturi V acuum Assembly , and generate 20”-30” of vacuum for a ...

  • Bravo View B409 - page 10

    Even though Bravo DoubleW all product corners and edges are thicker than the rest of the Containment sump, These areas recieve the most supceptable to physical damage by Installing Contractors. Y ou would do well to be extremely careful with these DoubleW all products while storing, moving, transporting and Installing these critical environment al ...

  • Bravo View B409 - page 11

    E - CONNECTING T O MANOMETER E.1 - At this point, after the ALDP test, the interstice should still be holding vacuum. Maintain 20” of V acuum and slowly open ball valve to let fluid into the interstice until it exits the venturi assembly . Visually check whether the fluid level reaches the top of the interstitial sp ace. E.2 - Cut the barb & ...

  • Bravo View B409 - page 12

    12 ii-B409-DW-10A G - Concrete and Backfill Guidelines. T o ensure that no immediate or future damage is done to your Bravo T ank Sump Reducer components, make sure that your manhole skirt DOES NOT T OUCH OR REST ON THE T ANK SUMP SHOULDER. The Manhole Skirt should be kept at minimum of 4” away from the tank sump shoulder . Follow the manhole man ...

メーカー Bravo View カテゴリー Water Pump

Bravo View B409のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- B409の取扱説明書
- Bravo Viewの製品カード
- パンフレット
- またはBravo View B409の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bravo View B409の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bravo View B409の取り付け説明書、サービスマニュアル、簡易説明書、またはBravo View B409のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bravo View B409の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bravo View B409デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBravo View B409を使用するのを助ける技術的文書のことです。説明書は通常、全てのBravo View B409ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bravo Viewの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bravo View B409の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBravo View B409の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bravo View B409に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bravo View B409デバイスの基本機能を使うにあたってのヒント。 Bravo View B409のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bravo View B409に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBravo View B409のメーカー/サービスへの連絡先に関する情報。

Bravo View B409についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBravo View B409の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBravo View B409で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)