Manuale per l’uso Bravo View B409

12 pagine 0.51 mb
Scarica

Vai alla pagina of 12

Summary
  • Bravo View B409 - page 1

    F OR B409 D OUBLE W ALL T ANK S UMP WITH REINFORCED BOTT OM S. Bravo Systems, Inc. 2929 V ail A ve. - Commerce, CA 90040 (323) 888-4133 - F AX: (323) 888-4123 www .SBravo.com ii-B409-DW-10A INST ALLA TION INSTRUCTIONS Written by: Jonathan Smith ...

  • Bravo View B409 - page 2

    READ THESE INSTRUCTIONS - KEEP FOR FUTURE REFERENCE T ABLE OF CONTENTS DRY FITTING SUMP & EQUIPMENT ................................ p. 4 A) Installing & Securing.......................................................... p. 5 Install & T est Penetration Fittings...................................... p. 5 (A.4) B) Mantadory Air Integrity ...

  • Bravo View B409 - page 3

    3 ii-B409-DW-10A It is REQUIRED to visually check the V acuum gauge on each and every Bravo Systems Double W all product and write on its F AX report V acuum level , name of observer , and date for every DoubleW all Sump. A) There is a failure to comply with the Required written report guidelines as stated above. B) Double W all Products are DOUBLE ...

  • Bravo View B409 - page 4

    4 ii-B409-DW-10A EQUIPMENT DR Y -FIT - BEFORE INST ALLING PENETRA TION FITTINGS - BEFORE CUTTING OPEN SUMP INTERSTICE DR Y -FIT YOUR SUMP PIECES AND INTERNAL EQUIPMENT . PLAN YOUR INST ALLA TION AND MAKE SURE EVER YTHING FITS, AND WILL FIT LA TER DURING INST ALLA TION. Recommended T ools (NOT PROVIDED) Power/air Sanders. Acetone to clean up tools/a ...

  • Bravo View B409 - page 5

    A.1 - Visually inspect the p arts provided by Bravo Systems for In-transit damage and/or missing part s. Continue to keep the Sump clean of debris throughout your installation process. A.2 - Set your B409 Piping Sump where it must be per site plans. Secure the Sump to avoid movement while penetrating. A.3 - Mark where you will penetrate the Base/T ...

  • Bravo View B409 - page 6

    B - MANDA T OR Y AIR INTEGRITY TEST B.1 - Use test assembly and pressure sump to no more than 4 PSI. Close off with ball valve and resume other work. Allow 1 Hour before recording pressure. F IELD A IR I NTEGRITY I NSPECTION T EST : Hold pressure for a minimum of 1 hour for a Field Integrity Inspection T est. The T ank Sump P ASSES the integrity te ...

  • Bravo View B409 - page 7

    C - V ACUUM / HYDROST A TIC FILLING F IELD A IR I NTEGRITY I NSPECTION T EST : YOUR PRODUCT W ARRANTY WILL BE VOID IF YOU DO NOT Hold pressure for a minimum of 1 hour for a Field Integrity Inspection T est. After passing the pressure test, it is HIGHL Y RECOMMENDED that the 4 PSI is maintained for as long as possible, up until the time of backfill. ...

  • Bravo View B409 - page 8

    8 C.3 - Close off ball valve completely and prime the open ended 36” length of clear tubing with provided Interstitial Fluid. Use a liquid funnel. Filling Bravo Systems Double W all Product s with Brine (saline) solution will void the product warranty . Y ou must use only Bravo-Supplied Interstitial Fluid , p art # IMF-1GAL C.4 - Af ter filling t ...

  • Bravo View B409 - page 9

    D) ADV ANCED LEAK DETECTION PROCEDURE A Bravo Systems Exclusive detection method D.1 - Clear debris from the top open area of the DoubleW all Product and ensure that the interior walls are clean of debris and visible. D.2 - Apply V acuum to the sealed interstitial sp ace with the V enturi V acuum Assembly , and generate 20”-30” of vacuum for a ...

  • Bravo View B409 - page 10

    Even though Bravo DoubleW all product corners and edges are thicker than the rest of the Containment sump, These areas recieve the most supceptable to physical damage by Installing Contractors. Y ou would do well to be extremely careful with these DoubleW all products while storing, moving, transporting and Installing these critical environment al ...

  • Bravo View B409 - page 11

    E - CONNECTING T O MANOMETER E.1 - At this point, after the ALDP test, the interstice should still be holding vacuum. Maintain 20” of V acuum and slowly open ball valve to let fluid into the interstice until it exits the venturi assembly . Visually check whether the fluid level reaches the top of the interstitial sp ace. E.2 - Cut the barb & ...

  • Bravo View B409 - page 12

    12 ii-B409-DW-10A G - Concrete and Backfill Guidelines. T o ensure that no immediate or future damage is done to your Bravo T ank Sump Reducer components, make sure that your manhole skirt DOES NOT T OUCH OR REST ON THE T ANK SUMP SHOULDER. The Manhole Skirt should be kept at minimum of 4” away from the tank sump shoulder . Follow the manhole man ...

Fabbricante Bravo View Categoria Water Pump

I documenti che otteniamo dal fabbricante del dispositivoBravo View B409 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bravo View
- manuali per l’uso B409
- schede prodotto Bravo View
- opuscoli
- o etichette energetiche Bravo View B409
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bravo View B409.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bravo View B409, manuali di manutenzione, brevi manuali o manuali utente Bravo View B409. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bravo View B409.

Manuali per l’uso simili

Manuale completo del dispositivo Bravo View B409, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bravo View B409 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bravo View B409.

Il manuale per l’uso completo Bravo View, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bravo View B409 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bravo View B409, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bravo View B409 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bravo View B409 - che ci dovrebbe aiutare nei primi passi durante l'uso Bravo View B409
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bravo View B409
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bravo View B409 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bravo View B409?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bravo View B409 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bravo View B409 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)