Manuale per l’uso Aquacal HP7

29 pagine 0.52 mb
Scarica

Vai alla pagina of 29

Summary
  • Aquacal HP7 - page 1

    Operating & Service Instructions -for- HP7 Microprocessor Controller Includes Co nnecti on of External Controllers Dealer & Service Version Not for Distribution to Owners 2737 24 th Street North St. Petersburg, FL 33713 800-786-7751 www.aquacal.com ...

  • Aquacal HP7 - page 2

    Revised 10/14/03 TABLE of CONTENTS GENERAL DESCRIPTION of HP7 CONTROLLER ................................................. 4 HP7 CONTROLLER SPECIFICATIONS .................................................................... 4 Inputs: .................................................................................................................... ...

  • Aquacal HP7 - page 3

    2. Time Delay [dEL] : ......................................................................................................................12 3. Configuring for External C ontrollers [JAO] or [FS2]: ................................................................12 4. Water Sensor calibration [tSC]… .............................................. ...

  • Aquacal HP7 - page 4

    GENERAL DESCRIPTION of HP7 CONTROLLER The HP7 is a powerful microprocessor control designed for use in swimming pool & spa heat pumps. The control features 3-digit temperatur e and set point display, with programming changes easily performed via simple 3-button (key) operation. The HP7 offers precise water temperature contro l, accu rate defros ...

  • Aquacal HP7 - page 5

    Control Features: ♦ Compressor Operation ♦ Refrigerant Circuit Hi & Low-Pressure Lock Out ♦ Water Pump Option (Call Flex) ♦ Precise Evaporator Tem perature Control (Defrost Management) ♦ Anti Short Cycle Timer (4-Minute Restart Delay) ♦ Precise Water Temperature Control ♦ Corrosion Protection (Conformal Coating) CONTROL PANEL LAYO ...

  • Aquacal HP7 - page 6

    CONTROL PANEL SYMBOLS UNIT is HEATING WATER TEMPERATURE SET POINT ACTUAL WATER TEMPERATURE POOL SELECTION SPA SELECTION 6 ...

  • Aquacal HP7 - page 7

    SEQUENCE of OPERATION PUMP O F F POWER ON ______________________ "F LO " D isp la yed PUMP O N POWER ON ______________________ Wa t e r T e m p . D is p l a y e d SET PO IN T BEL O W 60 ºF ______________________ Heater i s "OFF " Pressi n g Up-Down Ke ys W ill Displa y "O FF" , Wa t er T em p . D i s p l ay e d SET PO ...

  • Aquacal HP7 - page 8

    8 START UP & SETTING OPERATING CONTROLS LEVEL-1 (Owner) ACCESS NOTE : Covered within this section are features and settings typically accessed first by the installer, and then remaining accessible by the end user (o wner ). Thes e features reside at the Level-1 ac cess point within the microprocessor . (Please see page-11 for information concer ...

  • Aquacal HP7 - page 9

    9 5. Changing The Pool Temperature Set Point: A. Using the Pool / Spa key, select the POOL tem perature set point. The pool set po int indicator light will confirm your selection by ligh ting. B. The pool temperature set point range is adjustable from 60 ° F. to 95 ° F (104 ° F in latest models) . using the Up ⇑ or Down ⇓ arrow keys. The des ...

  • Aquacal HP7 - page 10

    10 5) With [ELC] displayed, use the Up or Down a rrow keys to select a lock code number. The factory set lock code is “ 17”. Not depressing any buttons for 15- seconds will allow the control to save th e selection and return to the normal operating mode. Pressing the Pool / Spa key w ill also save the se lection and step to the next menu parame ...

  • Aquacal HP7 - page 11

    11 10. Fan Speed Control… This option is not applicable to any current m odels. If option present, factory default setting of “80” MUST remain. Controllers Ve rsion .06 or newer will not contain a FAN option. LEVEL-1 DISPLAY CODES Menu Codes Description Function [FLO] No water flow detected Displayed Code Message: Appears whenever the circula ...

  • Aquacal HP7 - page 12

    WARNING !!!! Dealer & Se rvice Center Use Only SERVICE & SET UP FEATURES LEVEL-2 ACCESS (Includes Configur ation for External Cont rollers) 1. Entering Service Menu: A. To enter the service menu leve l, depress and hold both the Up ⇑ and Down ⇓ arrow keys simultaneously until the code message [CF1] (Celsius Fahrenheit Selection) is disp ...

  • Aquacal HP7 - page 13

    WARNING !!!! Dealer & Se rvice Center Use Only 3.2: Configuring for External Controllers not Equipped with an “OFF” Position Switch, and All Double-Function Air Sw itch Controllers. (Also see Appendix Item “B”) 3.3 Remote Flow Sw itch / Automa tic Thermostat Switching [FS2]: (Also see Appendix Item “C”) A. Follow the steps 1a. throu ...

  • Aquacal HP7 - page 14

    WARNING !!!! Dealer & Se rvice Center Use Only B. Remove the unit front panel to gain a ccess to the defrost sensor . The defrost senso r will be found strapped to the suction line in comb ination with the TXV sensing bulb, or, in some models, the defrost sensor will be conn ected to the su ction lin e independent of the TXV bulb; C. Carefully ...

  • Aquacal HP7 - page 15

    WARNING !!!! Dealer & Se rvice Center Use Only 7. Changing Service Lock Code & “Backdoor” Entry… A. Changing the Code… The factory default Service Lock Code is “50”. Service personne l are strongly advised to retain the factory defau lt setting. However, should una uthorized access to the Level-2 (Service) menu be suspected, it ...

  • Aquacal HP7 - page 16

    WARNING !!!! Dealer & Se rvice Center Use Only 8) [DEL] will display (At this point you have entere d the service menu, and service- level programming will be possible.); 9) Push Pool/Spa pad until [LOC] appears on readout for the second time; 10) Push the up arrow,…The current, correct lock code will d isplay. Using the up or down arrow, the ...

  • Aquacal HP7 - page 17

    WARNING !!!! Dealer & Se rvice Center Use Only LEVEL-2 FAULT CODES Message Error Description Possible Cause [dPO] Defrost Sensor Open Cut or loose sensor wiring [PO] Water Temperature Sensor Open Cut or loose sensor wiring [dPC] Defrost sensor shorted Short circuit in defrost sensor wiring or defective sensor. [PC] Water temperatu re sensor sho ...

  • Aquacal HP7 - page 18

    WARNING !!!! Dealer & Se rvice Center Use Only APPENDIX Connecting to, and Confi guring Microprocessor for, Ext ernal Control : • A: Jandy and Pentair/Compool Brand Exte rnal Controllers Equipped with an “OFF” Position • B: External Controllers NOT Equipped with OFF Setting • C: Remote Flow Switch Connection • D: Call/Flex Option 18 ...

  • Aquacal HP7 - page 19

    Connecting Specific Jandy Or Pentair/Compool Controllers (See application table w ithin) Appendix- A Instructions For Connecting Specific Jandy Or Pentair/Compool Controllers To AquaCal’s HP7 Microprocessor 19 The microprocessor terminal block, labeled X , Y , Z, is located on the low-voltage portion of the MICROPROCESSOR POWER BOARD. (See figure ...

  • Aquacal HP7 - page 20

    Warning ! WARNING !!!! Dealer & Se rvice Center Use Only MAKE CERTAIN POWER SUPPLY TO HEATPUMP and CONT ROLLER IS DISCONNECTED PRIOR TO CONTINIUING. FAILURE TO DISCONNECT ELECTRICAL POWER MAY RESULT IN SERIOUS INJURY OR DEATH. 1. String 18/2 cable from the controller to the heat pump. 2. Locate the MICROPROCESSOR POWER BOARD inside the heat pum ...

  • Aquacal HP7 - page 21

    WARNING !!!! Dealer & Se rvice Center Use Only Warning ! MAKE CERTAIN POWER SUPPLY TO HEATPUMP and CONTROLLER IS DISCONNECTED PRIOR TO CONTINIUING. FAILURE TO DISCONNE CT ELECTRICAL POWER MAY RESULT IN SERIOUS INJURY OR DEATH. 1. String 18/3 cable from the controller to the heat pump. 2. Locate the MICROPROCESSOR POWER BOARD inside the heat pum ...

  • Aquacal HP7 - page 22

    Connecting Controllers Not Equipped With an OFF Setting (See application table within) WARNING !!!! Dealer & Se rvice Center Use Only Appendix- B HP-7 …. Interfacing External Controllers Not Equipped with an OFF Setting (Including, but not limited to, Double-Function Air Switches) Compatible Applications All Intermatic ”Air Force” Series ...

  • Aquacal HP7 - page 23

    Connecting a Remote Flow Switch WARNING !!!! Dealer & Se rvice Center Use Only Appendix- C Installing A Remote Flow Switch For Automatic Thermostat Switching A Remote Flow Switch kit is designed to allow autom atic selection of th e thermostats on AquaCal heaters equipped with HP7 Microprocessors with LED display. The Micr oprocesso r will rece ...

  • Aquacal HP7 - page 24

    FIGURE 1 FLOW SWITCH INSTALLED IN P OOL RETURN LINE WARNING !!!! Dealer & Se rvice Center Use Only SPA Return Line Installation 1. Disconnect power to the AquaCal Heater. 2. Remove front access panel and the electri c box cover (if equi pped) on the heater. 3. String the flow switches cable through an acces s hole in the side of the heater and ...

  • Aquacal HP7 - page 25

    FLOW SWITCH INSTALLED IN SPA RETURN LINE FIGURE 2 WARNING !!!! Dealer & Se rvice Center Use Only For Assistance Call AquaCal @ 800-786-7 751 Mon. – Fri. 8:00 AM – 5:00 PM 25 ...

  • Aquacal HP7 - page 26

    WARNING !!!! Dealer & Se rvice Center Use Only Installing a Call Flex Kit Appendix- D Installing a Call Flex Kit for Time Clock Management - Heaters Eq uipped With HP7 Microprocessor The CALL-FLEX is installed to manage the time clock to the desired heating style of the pool heat pump owner. With CALL-FLEX , owners select one of three heat mode ...

  • Aquacal HP7 - page 27

    WARNING !!!! Dealer & Se rvice Center Use Only Diagrams 27 ...

  • Aquacal HP7 - page 28

    CAUTION ! ONLY NON-ENERGIZING (“DRY” ) CIRCUIT SHOULD BE CONNECTED; NEVER APPLY EXTERNAL-SOURCE VOLTAGE TO THE HP7 MICROPROCE SSOR TERMINAL BOARD. FAILURE TO FOLLOW THESE INSTRUCTIONS WILL RESULT IN EQUIPMENT DAMAGE. WARNING ! DISCONNECT ALL ELECTRIC AL POWER WHI LE PERFORMIN G THIS WORK. FAIL URE TO FOLLOW THIS WARNING MAY RESU L T IN SERIOUS ...

  • Aquacal HP7 - page 29

    2737 24 th Street North St. Petersburg, FL 33713 800-786-7751 www.aquacal.com 29 ...

Fabbricante Aquacal Categoria Swimming Pool Heater

I documenti che otteniamo dal fabbricante del dispositivoAquacal HP7 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Aquacal
- manuali per l’uso HP7
- schede prodotto Aquacal
- opuscoli
- o etichette energetiche Aquacal HP7
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Aquacal HP7.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Aquacal HP7, manuali di manutenzione, brevi manuali o manuali utente Aquacal HP7. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Aquacal HP7.

Manuali per l’uso simili

Manuale completo del dispositivo Aquacal HP7, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Aquacal HP7 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Aquacal HP7.

Il manuale per l’uso completo Aquacal, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Aquacal HP7 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Aquacal HP7, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Aquacal HP7 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Aquacal HP7 - che ci dovrebbe aiutare nei primi passi durante l'uso Aquacal HP7
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Aquacal HP7
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Aquacal HP7 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Aquacal HP7?

Utilizza il modulo sottostante

Se non hai risolto il problema con Aquacal HP7 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Aquacal HP7 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)