    Operating & Service Instructions -for- HP7 Microprocessor Controller Includes Co nnecti on of External Controllers Dealer & Service Version Not for Distribution to Owners 2737 24 th Street North St. Petersburg, FL 33713 800-786-7751 www.aquacal.com ...

  • Aquacal HP7 - page 2

    Revised 10/14/03 TABLE of CONTENTS GENERAL DESCRIPTION of HP7 CONTROLLER ................................................. 4 HP7 CONTROLLER SPECIFICATIONS .................................................................... 4 Inputs: .................................................................................................................... ...

  • Aquacal HP7 - page 3

    2. Time Delay [dEL] : ......................................................................................................................12 3. Configuring for External C ontrollers [JAO] or [FS2]: ................................................................12 4. Water Sensor calibration [tSC]… .............................................. ...

  • Aquacal HP7 - page 4

    GENERAL DESCRIPTION of HP7 CONTROLLER The HP7 is a powerful microprocessor control designed for use in swimming pool & spa heat pumps. The control features 3-digit temperatur e and set point display, with programming changes easily performed via simple 3-button (key) operation. The HP7 offers precise water temperature contro l, accu rate defros ...

  • Aquacal HP7 - page 5

    Control Features: ♦ Compressor Operation ♦ Refrigerant Circuit Hi & Low-Pressure Lock Out ♦ Water Pump Option (Call Flex) ♦ Precise Evaporator Tem perature Control (Defrost Management) ♦ Anti Short Cycle Timer (4-Minute Restart Delay) ♦ Precise Water Temperature Control ♦ Corrosion Protection (Conformal Coating) CONTROL PANEL LAYO ...

  • Aquacal HP7 - page 6

    CONTROL PANEL SYMBOLS UNIT is HEATING WATER TEMPERATURE SET POINT ACTUAL WATER TEMPERATURE POOL SELECTION SPA SELECTION 6 ...

  • Aquacal HP7 - page 7

    SEQUENCE of OPERATION PUMP O F F POWER ON ______________________ "F LO " D isp la yed PUMP O N POWER ON ______________________ Wa t e r T e m p . D is p l a y e d SET PO IN T BEL O W 60 ºF ______________________ Heater i s "OFF " Pressi n g Up-Down Ke ys W ill Displa y "O FF" , Wa t er T em p . D i s p l ay e d SET PO ...

  • Aquacal HP7 - page 8

    8 START UP & SETTING OPERATING CONTROLS LEVEL-1 (Owner) ACCESS NOTE : Covered within this section are features and settings typically accessed first by the installer, and then remaining accessible by the end user (o wner ). Thes e features reside at the Level-1 ac cess point within the microprocessor . (Please see page-11 for information concer ...

  • Aquacal HP7 - page 9

    9 5. Changing The Pool Temperature Set Point: A. Using the Pool / Spa key, select the POOL tem perature set point. The pool set po int indicator light will confirm your selection by ligh ting. B. The pool temperature set point range is adjustable from 60 ° F. to 95 ° F (104 ° F in latest models) . using the Up ⇑ or Down ⇓ arrow keys. The des ...

  • Aquacal HP7 - page 10

    10 5) With [ELC] displayed, use the Up or Down a rrow keys to select a lock code number. The factory set lock code is “ 17”. Not depressing any buttons for 15- seconds will allow the control to save th e selection and return to the normal operating mode. Pressing the Pool / Spa key w ill also save the se lection and step to the next menu parame ...

  • Aquacal HP7 - page 11

    11 10. Fan Speed Control… This option is not applicable to any current m odels. If option present, factory default setting of “80” MUST remain. Controllers Ve rsion .06 or newer will not contain a FAN option. LEVEL-1 DISPLAY CODES Menu Codes Description Function [FLO] No water flow detected Displayed Code Message: Appears whenever the circula ...

  • Aquacal HP7 - page 12

    WARNING !!!! Dealer & Se rvice Center Use Only SERVICE & SET UP FEATURES LEVEL-2 ACCESS (Includes Configur ation for External Cont rollers) 1. Entering Service Menu: A. To enter the service menu leve l, depress and hold both the Up ⇑ and Down ⇓ arrow keys simultaneously until the code message [CF1] (Celsius Fahrenheit Selection) is disp ...

  • Aquacal HP7 - page 13

    WARNING !!!! Dealer & Se rvice Center Use Only 3.2: Configuring for External Controllers not Equipped with an “OFF” Position Switch, and All Double-Function Air Sw itch Controllers. (Also see Appendix Item “B”) 3.3 Remote Flow Sw itch / Automa tic Thermostat Switching [FS2]: (Also see Appendix Item “C”) A. Follow the steps 1a. throu ...

  • Aquacal HP7 - page 14

    WARNING !!!! Dealer & Se rvice Center Use Only B. Remove the unit front panel to gain a ccess to the defrost sensor . The defrost senso r will be found strapped to the suction line in comb ination with the TXV sensing bulb, or, in some models, the defrost sensor will be conn ected to the su ction lin e independent of the TXV bulb; C. Carefully ...

  • Aquacal HP7 - page 15

    WARNING !!!! Dealer & Se rvice Center Use Only 7. Changing Service Lock Code & “Backdoor” Entry… A. Changing the Code… The factory default Service Lock Code is “50”. Service personne l are strongly advised to retain the factory defau lt setting. However, should una uthorized access to the Level-2 (Service) menu be suspected, it ...

  • Aquacal HP7 - page 16

    WARNING !!!! Dealer & Se rvice Center Use Only 8) [DEL] will display (At this point you have entere d the service menu, and service- level programming will be possible.); 9) Push Pool/Spa pad until [LOC] appears on readout for the second time; 10) Push the up arrow,…The current, correct lock code will d isplay. Using the up or down arrow, the ...

  • Aquacal HP7 - page 17

    WARNING !!!! Dealer & Se rvice Center Use Only LEVEL-2 FAULT CODES Message Error Description Possible Cause [dPO] Defrost Sensor Open Cut or loose sensor wiring [PO] Water Temperature Sensor Open Cut or loose sensor wiring [dPC] Defrost sensor shorted Short circuit in defrost sensor wiring or defective sensor. [PC] Water temperatu re sensor sho ...

  • Aquacal HP7 - page 18

    WARNING !!!! Dealer & Se rvice Center Use Only APPENDIX Connecting to, and Confi guring Microprocessor for, Ext ernal Control : • A: Jandy and Pentair/Compool Brand Exte rnal Controllers Equipped with an “OFF” Position • B: External Controllers NOT Equipped with OFF Setting • C: Remote Flow Switch Connection • D: Call/Flex Option 18 ...

  • Aquacal HP7 - page 19

    Connecting Specific Jandy Or Pentair/Compool Controllers (See application table w ithin) Appendix- A Instructions For Connecting Specific Jandy Or Pentair/Compool Controllers To AquaCal’s HP7 Microprocessor 19 The microprocessor terminal block, labeled X , Y , Z, is located on the low-voltage portion of the MICROPROCESSOR POWER BOARD. (See figure ...

  • Aquacal HP7 - page 20

    Warning ! WARNING !!!! Dealer & Se rvice Center Use Only MAKE CERTAIN POWER SUPPLY TO HEATPUMP and CONT ROLLER IS DISCONNECTED PRIOR TO CONTINIUING. FAILURE TO DISCONNECT ELECTRICAL POWER MAY RESULT IN SERIOUS INJURY OR DEATH. 1. String 18/2 cable from the controller to the heat pump. 2. Locate the MICROPROCESSOR POWER BOARD inside the heat pum ...

  • Aquacal HP7 - page 21

    WARNING !!!! Dealer & Se rvice Center Use Only Warning ! MAKE CERTAIN POWER SUPPLY TO HEATPUMP and CONTROLLER IS DISCONNECTED PRIOR TO CONTINIUING. FAILURE TO DISCONNE CT ELECTRICAL POWER MAY RESULT IN SERIOUS INJURY OR DEATH. 1. String 18/3 cable from the controller to the heat pump. 2. Locate the MICROPROCESSOR POWER BOARD inside the heat pum ...

  • Aquacal HP7 - page 22

    Connecting Controllers Not Equipped With an OFF Setting (See application table within) WARNING !!!! Dealer & Se rvice Center Use Only Appendix- B HP-7 …. Interfacing External Controllers Not Equipped with an OFF Setting (Including, but not limited to, Double-Function Air Switches) Compatible Applications All Intermatic ”Air Force” Series ...

  • Aquacal HP7 - page 23

    Connecting a Remote Flow Switch WARNING !!!! Dealer & Se rvice Center Use Only Appendix- C Installing A Remote Flow Switch For Automatic Thermostat Switching A Remote Flow Switch kit is designed to allow autom atic selection of th e thermostats on AquaCal heaters equipped with HP7 Microprocessors with LED display. The Micr oprocesso r will rece ...

  • Aquacal HP7 - page 24

    FIGURE 1 FLOW SWITCH INSTALLED IN P OOL RETURN LINE WARNING !!!! Dealer & Se rvice Center Use Only SPA Return Line Installation 1. Disconnect power to the AquaCal Heater. 2. Remove front access panel and the electri c box cover (if equi pped) on the heater. 3. String the flow switches cable through an acces s hole in the side of the heater and ...

  • Aquacal HP7 - page 25

    FLOW SWITCH INSTALLED IN SPA RETURN LINE FIGURE 2 WARNING !!!! Dealer & Se rvice Center Use Only For Assistance Call AquaCal @ 800-786-7 751 Mon. – Fri. 8:00 AM – 5:00 PM 25 ...

  • Aquacal HP7 - page 26

    WARNING !!!! Dealer & Se rvice Center Use Only Installing a Call Flex Kit Appendix- D Installing a Call Flex Kit for Time Clock Management - Heaters Eq uipped With HP7 Microprocessor The CALL-FLEX is installed to manage the time clock to the desired heating style of the pool heat pump owner. With CALL-FLEX , owners select one of three heat mode ...

  • Aquacal HP7 - page 27

    WARNING !!!! Dealer & Se rvice Center Use Only Diagrams 27 ...

  • Aquacal HP7 - page 28

    CAUTION ! ONLY NON-ENERGIZING (“DRY” ) CIRCUIT SHOULD BE CONNECTED; NEVER APPLY EXTERNAL-SOURCE VOLTAGE TO THE HP7 MICROPROCE SSOR TERMINAL BOARD. FAILURE TO FOLLOW THESE INSTRUCTIONS WILL RESULT IN EQUIPMENT DAMAGE. WARNING ! DISCONNECT ALL ELECTRIC AL POWER WHI LE PERFORMIN G THIS WORK. FAIL URE TO FOLLOW THIS WARNING MAY RESU L T IN SERIOUS ...

  • Aquacal HP7 - page 29

    2737 24 th Street North St. Petersburg, FL 33713 800-786-7751 www.aquacal.com 29 ...

Fabricant Aquacal Catégorie Swimming Pool Heater

Les documents que nous recevons du fabricant de l'appareilAquacal HP7 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Aquacal
- manuels d’utilisations HP7
- fiches produit Aquacal
- dépliants
- ou étiquettes-énergie Aquacal HP7
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Aquacal HP7.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Aquacal HP7, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Aquacal HP7. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Aquacal HP7.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Aquacal HP7, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Aquacal HP7 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Aquacal HP7.

Le manuel d’utilisation complet Aquacal, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Aquacal HP7 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Aquacal HP7, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAquacal HP7 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Aquacal HP7 - qui devraient nous aider dans les premières étapes lors de l'utilisation Aquacal HP7
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Aquacal HP7
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Aquacal HP7 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Aquacal HP7?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Aquacal HP7, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Aquacal HP7 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)