    506488-01 Page 1 Issue 1008 T ABLE OF CONTENTS SAFETY ............................................................... 2 INST ALLA TION .................................................... 2 ST AR T -UP .......................................................... 10 OPERA TION ...................................................... 1 1 MAINTENANCE .... ...

  • Allied Air Enterprises 4PGE - page 2

    Page 2 506488-01 Issue 1008 INST ALLA TION These instructions must be hung on or near the furnace in a conspicuous place. These units are single p ackage air conditioners with gas heat designed for outdoor inst allation on a rooftop or a slab. The units are completely assembled. All piping, refrigerant charge, and electrical wiring are factory inst ...

  • Allied Air Enterprises 4PGE - page 3

    506488-01 Page 3 Issue 1008 Location Use the following guidelines to select a suitable location for the unit. 1. Unit is designed for outdoor installation only . Unit must be installed so all electrical component s are protected from water . 2. Condenser coils must have an unlimited supply of air . 3. For ground level installation, use a level pref ...

  • Allied Air Enterprises 4PGE - page 4

    Page 4 506488-01 Issue 1008 Roof Curb Inst allation If a roof curb is used, follow the manufacturer ’s Inst allation Instructions and be sure that all required clearances are observed (see following Clearances section). Clearances All units require certain clearances for proper operation and service. Refer to T able 1 for the minimum clearances t ...

  • Allied Air Enterprises 4PGE - page 5

    506488-01 Page 5 Issue 1008 a sidewalk, patio, or other walkway where the condensate could cause the surface to become slippery . The products of combustion must not be allowed to accumulate within a confined space and recirculate. V ent Hood The unit is shipped with the vent hood, screen, and sheet metal screws packed in the plastic bag cont ainin ...

  • Allied Air Enterprises 4PGE - page 6

    Page 6 506488-01 Issue 1008 Condensate Drain The PGE/SG package unit is equipped with a 3/4" FPT coupling for condensate line connection. Plumbing must conform to local codes. Use a sealing compound on male pipe threads. The condensate drain line must be properly trapped and routed to a suitable drain. See Figure 5 for proper drain arrangement ...

  • Allied Air Enterprises 4PGE - page 7

    506488-01 Page 7 Issue 1008 The gas supply line should be routed through the grommet on the side of the unit. Refer to Figure 7 to locate this access opening. If local codes allow the use of a flexible gas appliance connector , always use a new listed connector . Do not use a connector which has previously serviced another gas appliance. The furnac ...

  • Allied Air Enterprises 4PGE - page 8

    Page 8 506488-01 Issue 1008 Check all connections for leaks when piping is completed, using a soapy solution. Some soaps used for leak detection are corrosive to cert ain metals. Carefully rinse piping thoroughly after completing leak detection. Electrical Wiring All wiring should be done in accordance with the National Electrical Code, ANSI/NFP A ...

  • Allied Air Enterprises 4PGE - page 9

    506488-01 Page 9 Issue 1008 T ypical Wiring Connections Figure 8 RR C C Y Y W THERMOST A T OUTDOOR UNIT G G WITH ECONOMIZER C R R Y1 THERMOST A T OUTDOOR UNIT ECONOMIZER YELLOW W G G GREEN Y2 BLACK BLUE W W ORANGE (Not Used) WITHOUT ECONOMIZER L2 L1 POWER WIRING 208/230-1-60 (75°C MIN. WIRE) POWER WIRING 24V CONTROL WIRING (NEC CLASS 2) GROUND SCR ...

  • Allied Air Enterprises 4PGE - page 10

    Page 10 506488-01 Issue 1008 ST ART -UP Pre-Start Check List Complete the following checks before starting the unit: 1. Check the type of gas being supplied. Be sure it is the same as listed on the unit nameplate. 2. Make sure that the vent hood has been properly installed. T o Light Burners: 1. T urn off electrical power to unit. 2. T urn the ther ...

  • Allied Air Enterprises 4PGE - page 11

    506488-01 Page 11 Issue 1008 x 3600 x = Cubic Feet Per Revolution BTU/HR INPUT # Seconds Per Revolution Heating V alue For Natural Gas: Check the gas input rate by observing the gas meter , when available, making sure all other gas appliances are turned off. The test hand on the meter should be timed for at least one revolution. Note the number of ...

  • Allied Air Enterprises 4PGE - page 12

    Page 12 506488-01 Issue 1008 in the 10-second interval, then the ignition control will de-energize the gas valve. 4. The ignition control is designed to repeat this “trial for ignition” a total of three times. If, at the end of the third trial, a flame still has not been established, the ignition control will repeat the trial for ignition seque ...

  • Allied Air Enterprises 4PGE - page 13

    506488-01 Page 13 Issue 1008 V ariable Speed Motor Units equipped with a variable speed circulation air blower motor will deliver a constant airflow within a wide range of external static pressures. Other features of this variable speed motor include: Sof t S t art/S top – The variable speed motor will slowly ramp up to normal operating speed. Th ...

  • Allied Air Enterprises 4PGE - page 14

    Page 14 506488-01 Issue 1008 CONTROL SYSTEM DIAGNOSTICS Fault Codes T able 5 Out door Coil Dirt and debris should not be allowed to accumulate on the outdoor coil surface or other part s in the air circuit. Cleaning should be as often as necessary to keep coil clean. Use a brush, vacuum cleaner attachment, or other suitable means. If water is used ...

  • Allied Air Enterprises 4PGE - page 15

    506488-01 Page 15 Issue 1008 Figure 1 1 Connection Diagram Single Phase – PSC Motor ...

  • Allied Air Enterprises 4PGE - page 16

    Page 16 506488-01 Issue 1008 Figure 12 208/230V -1-60 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Y G W1 R C Y G W R C BLU GRN YEL WHT RED Y R C DIAGNOSTIC MODULE G Y1 Y2 O W1 EM C1 R HUM INDOOR BLOWER MO TOR ICM BOARD BLU RED 24V A C 1 625 4 3 FLAME FLAME SENSE GR Y BRN BLU ORN RED YEL GRN BLK WHT PUR BLK GRN PUR ...

Fabbricante Allied Air Enterprises Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoAllied Air Enterprises 4PGE possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Allied Air Enterprises
- manuali per l’uso 4PGE
- schede prodotto Allied Air Enterprises
- opuscoli
- o etichette energetiche Allied Air Enterprises 4PGE
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Allied Air Enterprises 4PGE.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Allied Air Enterprises 4PGE, manuali di manutenzione, brevi manuali o manuali utente Allied Air Enterprises 4PGE. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Allied Air Enterprises 4PGE.

Manuale completo del dispositivo Allied Air Enterprises 4PGE, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Allied Air Enterprises 4PGE dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Allied Air Enterprises 4PGE.

Il manuale per l’uso completo Allied Air Enterprises, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Allied Air Enterprises 4PGE - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Allied Air Enterprises 4PGE, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Allied Air Enterprises 4PGE che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Allied Air Enterprises 4PGE - che ci dovrebbe aiutare nei primi passi durante l'uso Allied Air Enterprises 4PGE
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Allied Air Enterprises 4PGE
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Allied Air Enterprises 4PGE in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Allied Air Enterprises 4PGE?

Utilizza il modulo sottostante

Se non hai risolto il problema con Allied Air Enterprises 4PGE con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Allied Air Enterprises 4PGE è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)