Manuale per l’uso American Power Conversion 100

17 pagine 0.46 mb
Scarica

Vai alla pagina of 17

Summary
  • American Power Conversion 100 - page 1

    990-1194A 12/2005 User Manual English Smart-UPS ® 750/1000/1500 VA 100/120/230 VAC 2U Rack Mount Uninterr uptible Pow er Supply ...

  • American Power Conversion 100 - page 2

    ...

  • American Power Conversion 100 - page 3

    1 Introduction The APC Un interru ptible Power S upply (UPS) is designed t o prevent blackouts , brownouts, s ags, and surges from reaching your computer and other valuable electronic equipment. The UPS filters small utility line fluctuations and isolates your equipment from large disturbances b y internally dis- connecting from the utility lin e. ...

  • American Power Conversion 100 - page 4

    2 Positioning the UPS Place the UPS where it will be used. The UPS is h eavy. Select a loca tion stur dy enough to h andle the weight. Do not operate the UPS where there is excessive dus t or the temperature and hum idity are outside the specified limits. P LACEMEN T Mounting the UPS in a Rack The UPS is heavy. To lighten it, y ou may remove the ba ...

  • American Power Conversion 100 - page 5

    3 Installing and Connecting the Battery and Attaching the Front Bezel Step 1 Step 2 Ste p 3 Ste p 4 Connect bat tery plug to UPS. Tuck wh ite batt ery cord into space above con nector. Connecting Equipment and Power to the UPS S MART -U PS R EA R P ANEL 100/120V Model s 120V Model O nly: Site wiri ng fault indi cator 230V Models ...

  • American Power Conversion 100 - page 6

    4 1. Connect equ ipment to the UPS. Note: Do not connect a laser prin ter to the UPS. A laser printer d raws signi ficantly m ore power than other typ es of equipm ent and may overload the UPS . 2. Add any option al accessories to the Sm art-Slot. 3. Using a pow er cord, plug th e UPS into a two-pol e, three-wire, groun ded receptacle only. Avoid u ...

  • American Power Conversion 100 - page 7

    5 2: O PERA TION S MART -U PS F RONT P ANEL Power On Power Off Online The online LED illu minates when the UPS is suppl ying utility power to the connected equipment. If the LED is not lit, the UPS is eit her not turn ed ON, or is su pplying battery pow er. AVR Tr im This LED illuminates to indicate the UPS is compensating for a hig h utility volta ...

  • American Power Conversion 100 - page 8

    6 Replace Battery Failure of a battery self-test cause s the UPS to emit short bee ps for one minute and the repl ace battery LED illuminates. Re fer to Trouble- shooting in this manual. Battery Disconnected The replace batte ry LED flashes and short beep is emitted every two seconds to indicate the battery is dis connected. Automatic Self-Te st Th ...

  • American Power Conversion 100 - page 9

    7 3: U SER C ONFIGU RA BLE I TEMS N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE SOF TWARE OR OP TIONAL S MAR T S LOT ACCESSORY CARDS . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Automa tic Self -Test Every 14 day s (336 hours) Every 7 day s (168 hours) , On Startup Only, No Self-Te st This func tion sets the int ...

  • American Power Conversion 100 - page 10

    8 N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE SOF TWARE OR OP TIONAL S MAR T S LOT ACCESSORY CARDS . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Low Battery Warning . PowerChute in terface softw are pr ovides auto- matic, unatte nded shut- down w hen a pprox ima tely two m inutes (by def ault) of battery oper a ...

  • American Power Conversion 100 - page 11

    9 4: S TO R AG E , M A INT ENA NCE , A ND T RANSPORTING Storage Store the UPS covered and positioned as for proper functioning, in a cool, dry location, with the bat - teries fully charged. At -15 t o +30 ° C (+5 to + 86 ° F), ch arge the UPS battery every six months. At +30 t o +45 ° C (+86 to + 113 ° F), charg e the UPS battery every three mo ...

  • American Power Conversion 100 - page 12

    10 5: T ROUBLESHOOTI NG Use the chart belo w to solve minor Smart-UPS installation and operation problems. Re fer to the APC web site, www.apc.com , for assistance with complex UPS problems . P ROBLEM AND P OSSI BLE C AUSE S OLUTION UPS WILL NOT TURN ON Batter y not conn ected prop - erly. Check that the battery conn ector is full y engaged. butto ...

  • American Power Conversion 100 - page 13

    11 P ROBLEM AND P OSSI BLE C AUSE S OLUTION T HE OVERLOAD LED IS LIT AN D T HE UPS EM ITS A SUSTAINED ALARM TONE The UPS is overload ed. The conn ected equ ipment exceed s th e specified “maxi mum load ” as de- fine d in Spec ificati ons a t the A PC we b site, ww w.apc .com . The alarm remai ns on until the overload is removed. Disco nnect non ...

  • American Power Conversion 100 - page 14

    12 P ROBLEM AND P OSSI BLE C AUSE S OLUTION T HERE IS NO U TILI TY P OWER AND THE UPS HAS BEEN TURNED OFF 120V/230 V Models : When the UPS is off and there is no util ity power, use t he cold start feature to apply po wer to the con nected equipm ent fr om the UPS battery . Cold start i s not a nor mal c ondi- tion. Press and hold t he button, (for ...

  • American Power Conversion 100 - page 15

    13 Service If the UPS requires s ervice do not return it to the dealer. In stead, follow these steps: 1. Revi ew the problem s dis cussed in th e Troubles hooting secti on of th is manual to eliminate com- mon probl ems . 2. If the problem persists, contact A PC Customer Service through the APC web site, www.apc.com/su pport .  Note the m odel n ...

  • American Power Conversion 100 - page 16

    14 6: R EGULA TOR Y A ND W AR R AN T Y I NFORMA TION Regulatory Agenc y Approvals a nd Radio Freque ncy Warnings 230V MODE LS This is a Class A pro duc t. I n a dom estic env iro nment this product m ay cause ra dio in terferen ce, in whi ch cas e the u ser m ay be req uir ed t o take cor rect ive a c- tions . 120V MODE LS This e qui pment has bee ...

  • American Power Conversion 100 - page 17

    15 Declaration of Conformity Limited Warranty America n Power Conversi on (APC) warran ts it s products to be free from defect s in materia ls and workmanshi p for a period of two year s from th e date of pu rcha se. Its ob ligat ion under t his warra nty is lim ited to repai ring or repla cin g, at it s ow n sol e o p- tion, any such defect ive p ...

Fabbricante American Power Conversion Categoria Power Supply

I documenti che otteniamo dal fabbricante del dispositivoAmerican Power Conversion 100 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici American Power Conversion
- manuali per l’uso 100
- schede prodotto American Power Conversion
- opuscoli
- o etichette energetiche American Power Conversion 100
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso American Power Conversion 100.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione American Power Conversion 100, manuali di manutenzione, brevi manuali o manuali utente American Power Conversion 100. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto American Power Conversion 100.

Manuale completo del dispositivo American Power Conversion 100, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare American Power Conversion 100 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti American Power Conversion 100.

Il manuale per l’uso completo American Power Conversion, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale American Power Conversion 100 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice American Power Conversion 100, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per American Power Conversion 100 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo American Power Conversion 100 - che ci dovrebbe aiutare nei primi passi durante l'uso American Power Conversion 100
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del American Power Conversion 100
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio American Power Conversion 100 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su American Power Conversion 100?

Utilizza il modulo sottostante

Se non hai risolto il problema con American Power Conversion 100 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con American Power Conversion 100 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine