  • American Power Conversion 100 - page 1

    990-1194A 12/2005 User Manual English Smart-UPS ® 750/1000/1500 VA 100/120/230 VAC 2U Rack Mount Uninterr uptible Pow er Supply ...

  • American Power Conversion 100 - page 2

    ...

  • American Power Conversion 100 - page 3

    1 Introduction The APC Un interru ptible Power S upply (UPS) is designed t o prevent blackouts , brownouts, s ags, and surges from reaching your computer and other valuable electronic equipment. The UPS filters small utility line fluctuations and isolates your equipment from large disturbances b y internally dis- connecting from the utility lin e. ...

  • American Power Conversion 100 - page 4

    2 Positioning the UPS Place the UPS where it will be used. The UPS is h eavy. Select a loca tion stur dy enough to h andle the weight. Do not operate the UPS where there is excessive dus t or the temperature and hum idity are outside the specified limits. P LACEMEN T Mounting the UPS in a Rack The UPS is heavy. To lighten it, y ou may remove the ba ...

  • American Power Conversion 100 - page 5

    3 Installing and Connecting the Battery and Attaching the Front Bezel Step 1 Step 2 Ste p 3 Ste p 4 Connect bat tery plug to UPS. Tuck wh ite batt ery cord into space above con nector. Connecting Equipment and Power to the UPS S MART -U PS R EA R P ANEL 100/120V Model s 120V Model O nly: Site wiri ng fault indi cator 230V Models ...

  • American Power Conversion 100 - page 6

    4 1. Connect equ ipment to the UPS. Note: Do not connect a laser prin ter to the UPS. A laser printer d raws signi ficantly m ore power than other typ es of equipm ent and may overload the UPS . 2. Add any option al accessories to the Sm art-Slot. 3. Using a pow er cord, plug th e UPS into a two-pol e, three-wire, groun ded receptacle only. Avoid u ...

  • American Power Conversion 100 - page 7

    5 2: O PERA TION S MART -U PS F RONT P ANEL Power On Power Off Online The online LED illu minates when the UPS is suppl ying utility power to the connected equipment. If the LED is not lit, the UPS is eit her not turn ed ON, or is su pplying battery pow er. AVR Tr im This LED illuminates to indicate the UPS is compensating for a hig h utility volta ...

  • American Power Conversion 100 - page 8

    6 Replace Battery Failure of a battery self-test cause s the UPS to emit short bee ps for one minute and the repl ace battery LED illuminates. Re fer to Trouble- shooting in this manual. Battery Disconnected The replace batte ry LED flashes and short beep is emitted every two seconds to indicate the battery is dis connected. Automatic Self-Te st Th ...

  • American Power Conversion 100 - page 9

    7 3: U SER C ONFIGU RA BLE I TEMS N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE SOF TWARE OR OP TIONAL S MAR T S LOT ACCESSORY CARDS . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Automa tic Self -Test Every 14 day s (336 hours) Every 7 day s (168 hours) , On Startup Only, No Self-Te st This func tion sets the int ...

  • American Power Conversion 100 - page 10

    8 N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE SOF TWARE OR OP TIONAL S MAR T S LOT ACCESSORY CARDS . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Low Battery Warning . PowerChute in terface softw are pr ovides auto- matic, unatte nded shut- down w hen a pprox ima tely two m inutes (by def ault) of battery oper a ...

  • American Power Conversion 100 - page 11

    9 4: S TO R AG E , M A INT ENA NCE , A ND T RANSPORTING Storage Store the UPS covered and positioned as for proper functioning, in a cool, dry location, with the bat - teries fully charged. At -15 t o +30 ° C (+5 to + 86 ° F), ch arge the UPS battery every six months. At +30 t o +45 ° C (+86 to + 113 ° F), charg e the UPS battery every three mo ...

  • American Power Conversion 100 - page 12

    10 5: T ROUBLESHOOTI NG Use the chart belo w to solve minor Smart-UPS installation and operation problems. Re fer to the APC web site, www.apc.com , for assistance with complex UPS problems . P ROBLEM AND P OSSI BLE C AUSE S OLUTION UPS WILL NOT TURN ON Batter y not conn ected prop - erly. Check that the battery conn ector is full y engaged. butto ...

  • American Power Conversion 100 - page 13

    11 P ROBLEM AND P OSSI BLE C AUSE S OLUTION T HE OVERLOAD LED IS LIT AN D T HE UPS EM ITS A SUSTAINED ALARM TONE The UPS is overload ed. The conn ected equ ipment exceed s th e specified “maxi mum load ” as de- fine d in Spec ificati ons a t the A PC we b site, ww w.apc .com . The alarm remai ns on until the overload is removed. Disco nnect non ...

  • American Power Conversion 100 - page 14

    12 P ROBLEM AND P OSSI BLE C AUSE S OLUTION T HERE IS NO U TILI TY P OWER AND THE UPS HAS BEEN TURNED OFF 120V/230 V Models : When the UPS is off and there is no util ity power, use t he cold start feature to apply po wer to the con nected equipm ent fr om the UPS battery . Cold start i s not a nor mal c ondi- tion. Press and hold t he button, (for ...

  • American Power Conversion 100 - page 15

    13 Service If the UPS requires s ervice do not return it to the dealer. In stead, follow these steps: 1. Revi ew the problem s dis cussed in th e Troubles hooting secti on of th is manual to eliminate com- mon probl ems . 2. If the problem persists, contact A PC Customer Service through the APC web site, www.apc.com/su pport .  Note the m odel n ...

  • American Power Conversion 100 - page 16

    14 6: R EGULA TOR Y A ND W AR R AN T Y I NFORMA TION Regulatory Agenc y Approvals a nd Radio Freque ncy Warnings 230V MODE LS This is a Class A pro duc t. I n a dom estic env iro nment this product m ay cause ra dio in terferen ce, in whi ch cas e the u ser m ay be req uir ed t o take cor rect ive a c- tions . 120V MODE LS This e qui pment has bee ...

  • American Power Conversion 100 - page 17

    15 Declaration of Conformity Limited Warranty America n Power Conversi on (APC) warran ts it s products to be free from defect s in materia ls and workmanshi p for a period of two year s from th e date of pu rcha se. Its ob ligat ion under t his warra nty is lim ited to repai ring or repla cin g, at it s ow n sol e o p- tion, any such defect ive p ...

Produzent American Power Conversion Kategorie Power Supply

Dokumente, die wir vom Produzenten des Geräts American Power Conversion 100 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen American Power Conversion
- Bedienungsanleitungen 100
- Produktkarten American Power Conversion
- Informationsbroschüren
- oder Energieetiketten American Power Conversion 100
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung American Power Conversion 100.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen American Power Conversion 100, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen American Power Conversion 100. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts American Power Conversion 100 ansehen.

Die komplette Bedienungsanleitung des Geräts American Power Conversion 100, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von American Power Conversion 100 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von American Power Conversion 100 verständlich ist.

Eine gänzliche Bedienungsanleitung von American Power Conversion sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von American Power Conversion 100 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von American Power Conversion 100 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich American Power Conversion 100, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts American Power Conversion 100 - die uns die ersten Schritte während der Nutzung von American Power Conversion 100 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit American Power Conversion 100 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von American Power Conversion 100 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich American Power Conversion 100?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit American Power Conversion 100 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit American Power Conversion 100 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen