  • American Power Conversion 100 - page 1

    990-1194A 12/2005 User Manual English Smart-UPS ® 750/1000/1500 VA 100/120/230 VAC 2U Rack Mount Uninterr uptible Pow er Supply ...

  • American Power Conversion 100 - page 2

    ...

  • American Power Conversion 100 - page 3

    1 Introduction The APC Un interru ptible Power S upply (UPS) is designed t o prevent blackouts , brownouts, s ags, and surges from reaching your computer and other valuable electronic equipment. The UPS filters small utility line fluctuations and isolates your equipment from large disturbances b y internally dis- connecting from the utility lin e. ...

  • American Power Conversion 100 - page 4

    2 Positioning the UPS Place the UPS where it will be used. The UPS is h eavy. Select a loca tion stur dy enough to h andle the weight. Do not operate the UPS where there is excessive dus t or the temperature and hum idity are outside the specified limits. P LACEMEN T Mounting the UPS in a Rack The UPS is heavy. To lighten it, y ou may remove the ba ...

  • American Power Conversion 100 - page 5

    3 Installing and Connecting the Battery and Attaching the Front Bezel Step 1 Step 2 Ste p 3 Ste p 4 Connect bat tery plug to UPS. Tuck wh ite batt ery cord into space above con nector. Connecting Equipment and Power to the UPS S MART -U PS R EA R P ANEL 100/120V Model s 120V Model O nly: Site wiri ng fault indi cator 230V Models ...

  • American Power Conversion 100 - page 6

    4 1. Connect equ ipment to the UPS. Note: Do not connect a laser prin ter to the UPS. A laser printer d raws signi ficantly m ore power than other typ es of equipm ent and may overload the UPS . 2. Add any option al accessories to the Sm art-Slot. 3. Using a pow er cord, plug th e UPS into a two-pol e, three-wire, groun ded receptacle only. Avoid u ...

  • American Power Conversion 100 - page 7

    5 2: O PERA TION S MART -U PS F RONT P ANEL Power On Power Off Online The online LED illu minates when the UPS is suppl ying utility power to the connected equipment. If the LED is not lit, the UPS is eit her not turn ed ON, or is su pplying battery pow er. AVR Tr im This LED illuminates to indicate the UPS is compensating for a hig h utility volta ...

  • American Power Conversion 100 - page 8

    6 Replace Battery Failure of a battery self-test cause s the UPS to emit short bee ps for one minute and the repl ace battery LED illuminates. Re fer to Trouble- shooting in this manual. Battery Disconnected The replace batte ry LED flashes and short beep is emitted every two seconds to indicate the battery is dis connected. Automatic Self-Te st Th ...

  • American Power Conversion 100 - page 9

    7 3: U SER C ONFIGU RA BLE I TEMS N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE SOF TWARE OR OP TIONAL S MAR T S LOT ACCESSORY CARDS . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Automa tic Self -Test Every 14 day s (336 hours) Every 7 day s (168 hours) , On Startup Only, No Self-Te st This func tion sets the int ...

  • American Power Conversion 100 - page 10

    8 N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE SOF TWARE OR OP TIONAL S MAR T S LOT ACCESSORY CARDS . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Low Battery Warning . PowerChute in terface softw are pr ovides auto- matic, unatte nded shut- down w hen a pprox ima tely two m inutes (by def ault) of battery oper a ...

  • American Power Conversion 100 - page 11

    9 4: S TO R AG E , M A INT ENA NCE , A ND T RANSPORTING Storage Store the UPS covered and positioned as for proper functioning, in a cool, dry location, with the bat - teries fully charged. At -15 t o +30 ° C (+5 to + 86 ° F), ch arge the UPS battery every six months. At +30 t o +45 ° C (+86 to + 113 ° F), charg e the UPS battery every three mo ...

  • American Power Conversion 100 - page 12

    10 5: T ROUBLESHOOTI NG Use the chart belo w to solve minor Smart-UPS installation and operation problems. Re fer to the APC web site, www.apc.com , for assistance with complex UPS problems . P ROBLEM AND P OSSI BLE C AUSE S OLUTION UPS WILL NOT TURN ON Batter y not conn ected prop - erly. Check that the battery conn ector is full y engaged. butto ...

  • American Power Conversion 100 - page 13

    11 P ROBLEM AND P OSSI BLE C AUSE S OLUTION T HE OVERLOAD LED IS LIT AN D T HE UPS EM ITS A SUSTAINED ALARM TONE The UPS is overload ed. The conn ected equ ipment exceed s th e specified “maxi mum load ” as de- fine d in Spec ificati ons a t the A PC we b site, ww w.apc .com . The alarm remai ns on until the overload is removed. Disco nnect non ...

  • American Power Conversion 100 - page 14

    12 P ROBLEM AND P OSSI BLE C AUSE S OLUTION T HERE IS NO U TILI TY P OWER AND THE UPS HAS BEEN TURNED OFF 120V/230 V Models : When the UPS is off and there is no util ity power, use t he cold start feature to apply po wer to the con nected equipm ent fr om the UPS battery . Cold start i s not a nor mal c ondi- tion. Press and hold t he button, (for ...

  • American Power Conversion 100 - page 15

    13 Service If the UPS requires s ervice do not return it to the dealer. In stead, follow these steps: 1. Revi ew the problem s dis cussed in th e Troubles hooting secti on of th is manual to eliminate com- mon probl ems . 2. If the problem persists, contact A PC Customer Service through the APC web site, www.apc.com/su pport .  Note the m odel n ...

  • American Power Conversion 100 - page 16

    14 6: R EGULA TOR Y A ND W AR R AN T Y I NFORMA TION Regulatory Agenc y Approvals a nd Radio Freque ncy Warnings 230V MODE LS This is a Class A pro duc t. I n a dom estic env iro nment this product m ay cause ra dio in terferen ce, in whi ch cas e the u ser m ay be req uir ed t o take cor rect ive a c- tions . 120V MODE LS This e qui pment has bee ...

  • American Power Conversion 100 - page 17

    15 Declaration of Conformity Limited Warranty America n Power Conversi on (APC) warran ts it s products to be free from defect s in materia ls and workmanshi p for a period of two year s from th e date of pu rcha se. Its ob ligat ion under t his warra nty is lim ited to repai ring or repla cin g, at it s ow n sol e o p- tion, any such defect ive p ...

メーカー American Power Conversion カテゴリー Power Supply

American Power Conversion 100のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 100の取扱説明書
- American Power Conversionの製品カード
- パンフレット
- またはAmerican Power Conversion 100の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、American Power Conversion 100の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、American Power Conversion 100の取り付け説明書、サービスマニュアル、簡易説明書、またはAmerican Power Conversion 100のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、American Power Conversion 100の製品を使用するにあたって最も人気のある説明書を閲覧できます。

American Power Conversion 100デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAmerican Power Conversion 100を使用するのを助ける技術的文書のことです。説明書は通常、全てのAmerican Power Conversion 100ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

American Power Conversionの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. American Power Conversion 100の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAmerican Power Conversion 100の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。American Power Conversion 100に関してこのドキュメントで見つけることができる全てのヒントの目次
3. American Power Conversion 100デバイスの基本機能を使うにあたってのヒント。 American Power Conversion 100のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。American Power Conversion 100に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAmerican Power Conversion 100のメーカー/サービスへの連絡先に関する情報。

American Power Conversion 100についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAmerican Power Conversion 100の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAmerican Power Conversion 100で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください