Manuale per l’uso Bryant 538J-18-1

12 pagine 0.31 mb
Scarica

Vai alla pagina of 12

Summary
  • Bryant 538J-18-1 - page 1

    Canc els: New II 53 8J-1 8- 1 1/15/02 CONTENTS Pa g e SAFETY CONSIDERA TIONS . . . . . . . . . . . . . . . . . . . . . . . . . 1 INST ALLA TION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 -7 I. Complete Pre-I nstallation Che cks . . . . . . . . . . . . . . 1 II. Rig a nd M ount Unit . . . . . . . . . . . . . . . . . . . ...

  • Bryant 538J-18-1 - page 2

    — 2 — Fig. 2 — 5 38J018-060 — Dimensiona l Dra wing NO TES: 1. Required clearances: With co il f acing wall, allow 6 ″ (156.4 mm) minimum clearance on coil sid e and coil end, a nd 3 ft (914 .4 mm) min imum clearanc e on compressor end and fan side. Wi th fan f a cing wall, allow 8 ″ (203 .2 mm) minimu m clearance on fan sid e and coil ...

  • Bryant 538J-18-1 - page 3

    — 3 — II. RIG AND MOUNT UNIT A. Mountin g on Gr ound Mount uni t on a solid, lev el concrete pa d. P osition unit so water or ice f rom roof do es not fa ll directl y into unit. Field- fabric ated stack ing kits can be used whe n units are to b e stac ked. If condition s or local code s require un it to be fas- tened to a pad, 6 field-supplied ...

  • Bryant 538J-18-1 - page 4

    — 4 — B. Make Pipin g Sweat Connectio ns Remo ve pla stic ca ps from liq uid an d suctio n servic e valv es . Use ref rigerant gr ade tubi ng. Service v alves are closed from the factory and ready for brazing. After wrapping the service valve with a wet cloth, the tubing set can be brazed to the serv ice valv e using eith er silv er bea ring or ...

  • Bryant 538J-18-1 - page 5

    — 5 — T able 1A — Ph ysical Data (English) NO TE: Line siz es are f or runs up to 25 f eet. T able 1B — Ph ysical Dat a (SI) NO TE: Line siz es are f or runs up to 7.6 m. UNIT 538J 018 024 030 036 048 060 NOMINAL CAP ACI TY (Btuh) 18,000 24,000 30,000 36,000 48,000 60, 000 UNIT OPERA TING WEIGHT (lb) 130 136 161 185 222 249 COMPRESSOR Herme ...

  • Bryant 538J-18-1 - page 6

    — 6 — LEGEND C— Contactor (12-va) HC — Heating Control IFM — Indoor- F an Motor IFR — Indoor-F an Relay TRANS — T ransf or mer Field Wiring F ac tory Wir ing *The IFR and IFM are located in indoor unit on heating-cooling applications. If accessory IFR is required f or cooling-only applications, locate (IFR) in fan coil. NO TES: 1. Ref ...

  • Bryant 538J-18-1 - page 7

    — 7 — T able 2 — Am eric an/E uropean Wire C on versio ns LEGEND ST ART -UP I. PRELIMINAR Y CHECKS 1. Che ck that all interna l wiring co nnectio ns are tight and that barriers , covers, and pane ls are in place. 2. M ake certai n field el ectric al power source ag rees with unit nameplate rati ng . 3. Op en all s e rvice va lves . II. LEAK T ...

  • Bryant 538J-18-1 - page 8

    — 8 — T able 3 — Electrica l Data LEGEND *P ermissible limits of the v oltage range at which uni t will oper ate satisfactorily . †Time-de lay fuse. NO T ES: 1. Control circuit is 24 v on all unit s and requires an external po wer source . 2. All motors and compressors contain internal overload protecti on. 3. In compliance with NEC (U .S.A ...

  • Bryant 538J-18-1 - page 9

    — 9 — 10. If air tempe rature ent ering outdoor coil or pres sure at suction valve chan ges , charge to new suctio n line temperature indi cated on chart. NO TE: The above procedure is independent of indoor air quantity . B. Subcooling M ethod (Cooling, TXV) T o c heck an d adjust charge during c ooling se ason, us e T ables 6A and 6B an d the ...

  • Bryant 538J-18-1 - page 10

    — 10 — MAINTENANCE I. LUBRICA TION The ou tdoor fa n motor i s facto ry lubr icated and requ ires no oil. II. COMPRESSOR The c omp ressor con tains fac tory oil c har ges ; rep lac e oil w hen lost. S ee T ables 1A an d 1B for oil rechar ge. Recommended o il is Sont ex 200L T for all un its . III. CLEANING COILS Coil should be washed out with w ...

  • Bryant 538J-18-1 - page 11

    — 11 — TR OUBLESHOO TING TROUBLESHOO TING CHART — COOLING CYCLE ...

  • Bryant 538J-18-1 - page 12

    Copyright 20 02 Br yant Heating & Cooling Systems Printe d in Mexico CA T ALOG NO. 5353-80 2 ...

Fabbricante Bryant Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoBryant 538J-18-1 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bryant
- manuali per l’uso 538J-18-1
- schede prodotto Bryant
- opuscoli
- o etichette energetiche Bryant 538J-18-1
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bryant 538J-18-1.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bryant 538J-18-1, manuali di manutenzione, brevi manuali o manuali utente Bryant 538J-18-1. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bryant 538J-18-1.

Manuali per l’uso simili

Manuale completo del dispositivo Bryant 538J-18-1, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bryant 538J-18-1 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bryant 538J-18-1.

Il manuale per l’uso completo Bryant, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bryant 538J-18-1 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bryant 538J-18-1, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bryant 538J-18-1 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bryant 538J-18-1 - che ci dovrebbe aiutare nei primi passi durante l'uso Bryant 538J-18-1
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bryant 538J-18-1
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bryant 538J-18-1 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bryant 538J-18-1?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bryant 538J-18-1 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bryant 538J-18-1 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)