Bryant 538J-18-1の取扱説明書

12ページ 0.31 mb
ダウンロード

ページに移動 of 12

Summary
  • Bryant 538J-18-1 - page 1

    Canc els: New II 53 8J-1 8- 1 1/15/02 CONTENTS Pa g e SAFETY CONSIDERA TIONS . . . . . . . . . . . . . . . . . . . . . . . . . 1 INST ALLA TION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 -7 I. Complete Pre-I nstallation Che cks . . . . . . . . . . . . . . 1 II. Rig a nd M ount Unit . . . . . . . . . . . . . . . . . . . ...

  • Bryant 538J-18-1 - page 2

    — 2 — Fig. 2 — 5 38J018-060 — Dimensiona l Dra wing NO TES: 1. Required clearances: With co il f acing wall, allow 6 ″ (156.4 mm) minimum clearance on coil sid e and coil end, a nd 3 ft (914 .4 mm) min imum clearanc e on compressor end and fan side. Wi th fan f a cing wall, allow 8 ″ (203 .2 mm) minimu m clearance on fan sid e and coil ...

  • Bryant 538J-18-1 - page 3

    — 3 — II. RIG AND MOUNT UNIT A. Mountin g on Gr ound Mount uni t on a solid, lev el concrete pa d. P osition unit so water or ice f rom roof do es not fa ll directl y into unit. Field- fabric ated stack ing kits can be used whe n units are to b e stac ked. If condition s or local code s require un it to be fas- tened to a pad, 6 field-supplied ...

  • Bryant 538J-18-1 - page 4

    — 4 — B. Make Pipin g Sweat Connectio ns Remo ve pla stic ca ps from liq uid an d suctio n servic e valv es . Use ref rigerant gr ade tubi ng. Service v alves are closed from the factory and ready for brazing. After wrapping the service valve with a wet cloth, the tubing set can be brazed to the serv ice valv e using eith er silv er bea ring or ...

  • Bryant 538J-18-1 - page 5

    — 5 — T able 1A — Ph ysical Data (English) NO TE: Line siz es are f or runs up to 25 f eet. T able 1B — Ph ysical Dat a (SI) NO TE: Line siz es are f or runs up to 7.6 m. UNIT 538J 018 024 030 036 048 060 NOMINAL CAP ACI TY (Btuh) 18,000 24,000 30,000 36,000 48,000 60, 000 UNIT OPERA TING WEIGHT (lb) 130 136 161 185 222 249 COMPRESSOR Herme ...

  • Bryant 538J-18-1 - page 6

    — 6 — LEGEND C— Contactor (12-va) HC — Heating Control IFM — Indoor- F an Motor IFR — Indoor-F an Relay TRANS — T ransf or mer Field Wiring F ac tory Wir ing *The IFR and IFM are located in indoor unit on heating-cooling applications. If accessory IFR is required f or cooling-only applications, locate (IFR) in fan coil. NO TES: 1. Ref ...

  • Bryant 538J-18-1 - page 7

    — 7 — T able 2 — Am eric an/E uropean Wire C on versio ns LEGEND ST ART -UP I. PRELIMINAR Y CHECKS 1. Che ck that all interna l wiring co nnectio ns are tight and that barriers , covers, and pane ls are in place. 2. M ake certai n field el ectric al power source ag rees with unit nameplate rati ng . 3. Op en all s e rvice va lves . II. LEAK T ...

  • Bryant 538J-18-1 - page 8

    — 8 — T able 3 — Electrica l Data LEGEND *P ermissible limits of the v oltage range at which uni t will oper ate satisfactorily . †Time-de lay fuse. NO T ES: 1. Control circuit is 24 v on all unit s and requires an external po wer source . 2. All motors and compressors contain internal overload protecti on. 3. In compliance with NEC (U .S.A ...

  • Bryant 538J-18-1 - page 9

    — 9 — 10. If air tempe rature ent ering outdoor coil or pres sure at suction valve chan ges , charge to new suctio n line temperature indi cated on chart. NO TE: The above procedure is independent of indoor air quantity . B. Subcooling M ethod (Cooling, TXV) T o c heck an d adjust charge during c ooling se ason, us e T ables 6A and 6B an d the ...

  • Bryant 538J-18-1 - page 10

    — 10 — MAINTENANCE I. LUBRICA TION The ou tdoor fa n motor i s facto ry lubr icated and requ ires no oil. II. COMPRESSOR The c omp ressor con tains fac tory oil c har ges ; rep lac e oil w hen lost. S ee T ables 1A an d 1B for oil rechar ge. Recommended o il is Sont ex 200L T for all un its . III. CLEANING COILS Coil should be washed out with w ...

  • Bryant 538J-18-1 - page 11

    — 11 — TR OUBLESHOO TING TROUBLESHOO TING CHART — COOLING CYCLE ...

  • Bryant 538J-18-1 - page 12

    Copyright 20 02 Br yant Heating & Cooling Systems Printe d in Mexico CA T ALOG NO. 5353-80 2 ...

メーカー Bryant カテゴリー Air Conditioner

Bryant 538J-18-1のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 538J-18-1の取扱説明書
- Bryantの製品カード
- パンフレット
- またはBryant 538J-18-1の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bryant 538J-18-1の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bryant 538J-18-1の取り付け説明書、サービスマニュアル、簡易説明書、またはBryant 538J-18-1のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bryant 538J-18-1の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bryant 538J-18-1デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBryant 538J-18-1を使用するのを助ける技術的文書のことです。説明書は通常、全てのBryant 538J-18-1ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bryantの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bryant 538J-18-1の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBryant 538J-18-1の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bryant 538J-18-1に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bryant 538J-18-1デバイスの基本機能を使うにあたってのヒント。 Bryant 538J-18-1のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bryant 538J-18-1に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBryant 538J-18-1のメーカー/サービスへの連絡先に関する情報。

Bryant 538J-18-1についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBryant 538J-18-1の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBryant 538J-18-1で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)