    W ARNING : Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer , service agency or the gas supplier . Upon completion of the installation, these instructions should be handed to the user of the applianc ...

  • AquaStar 125B LPS - page 2

    ...

  • AquaStar 125B LPS - page 3

    3 ...

  • AquaStar 125B LPS - page 4

    4 PROPER LOCA TION FOR INST ALLING YOUR HEA TER Carefully select the location of your new heater . For your safety and for proper heater operation, you must provide an abundant supply of combustion air and a proper venting installation. The heater may still operate even when improperly vented. It will, however , be less efficient and could eventual ...

  • AquaStar 125B LPS - page 5

    5 COMBUSTION AIR REQUIREMENTS Observe the following instructions concerning combustion air . Appliances located in unconfined spaces: a) An unconfined space is one whose volume is greater than 50 cubic feet per 1000 Btu per hour of the combined rating of all appliances installed in the space. That would be 5850 cubic feet for the AquaStar 125B “S ...

  • AquaStar 125B LPS - page 6

    6 Fig. 3 - Flue Adaptor for High Altitude Installations 5” X 6” ADAPTOR USED ON HIGH AL TITUDE MOUNTING INST ALLA TION The Aquastar 125 B “S” is design certified for mounting on a wall. Do not install this appliance on a carpeted wall or over floor covering which is combustible, such as carpet. The heater must be mounted on a wall using app ...

  • AquaStar 125B LPS - page 7

    7 W ARNING : Failure TO INCREASE THE VENT SIZE TO SIX INCHES AND/or assure that the manifold pressure is set to proper value listed for applications at high altitudes will cause unsafe venting, asphyxiation, and will void IAS Certification. GAS CONNECTIONS and Gas Regulator Before connecting the gas supply , check the rating plate on the right side ...

  • AquaStar 125B LPS - page 8

    8 FOR YOUR SAFETY READ BEFORE LIGHTING THE PILOT W arning : If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life A. This appliance has a piezo-igniter for lighting the pilot burner . When lighting the pilot, follow these instructions exactly . B. BEFORE LIGHTING sm ...

  • AquaStar 125B LPS - page 9

    9 INFORMA TION ABOUT W A TER TEMPERA TURE The AquaStar 125B LPS and 125B NGS water heaters have a gas control that modulates burner output in response to water flow . Its purpose is to ensure that the hot water temperature will remain steady , although the water flow demand might vary (down to 1/2 gal/minute). The AquaStar 125 B”S” will produce ...

  • AquaStar 125B LPS - page 10

    10 TROUBLE SHOOTING Introduction The AquaStar 125 B “S” burners are activated by a water flow valve. Numerous water related problems can cause this water valve to malfunction such as: Insufficient water flow volume to activate the burners at its minimum flow requirement; Dirt in the water flow valve causing it to malfunction; Sediment build-up ...

  • AquaStar 125B LPS - page 11

    11 BURNERS DO NOT IGNITE WHEN HOT W A TER IS TURNED ON 1. Pilot is not on. Light the pilot. See lighting instructions. 2. Gas valve button not positioned on Burner Position Be sure once the pilot flame is on, that after a 15 to 20 second wait, the main burner button ( ) is pushed all the way in. 3. Cold incoming water connection made to wrong side ...

  • AquaStar 125B LPS - page 12

    12 the AquaStar ’s outlet pipe with your hand) and at the tap. If these two are very different, check for mixing valve or plumbing crossover (see “MAIN BURNERS WILL NOT IGNITE...” paragraph #6). 6. Parts in water flow valve are corroded so that the gas passage is not fully opening. Contact your service person or Controlled Energy . HOT W A TE ...

  • AquaStar 125B LPS - page 13

    13 ...

  • AquaStar 125B LPS - page 14

    14 AQ 125 BS Fig. 1 1 - INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST ...

  • AquaStar 125B LPS - page 15

    15 Fig. 1 1 INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST 125BS 1 Cover 8 705 421 033 2 Cap cover 8 703 304 01 1 3 Panel back 8 705 402 164 4 Draft divertor 8 705 505 354 5 Heat exchanger 8 705 406 189 6 Hot water pipe 8 700 705 431 7 Cold water pipe 8 700 705 294 8 Heat exchanger washer 8 710 103 045 9 Overheat sensor (ECO) 8 707 206 017 10 Main bur ...

  • AquaStar 125B LPS - page 16

    Replacement Parts available from North American Distributor CONTROLLED ENERGY CORP . 340 Mad River Park V ermont 05673 (U.S.A.) Phone 800-642-31 1 1 Fax (802) 496-6924 WWW .CECHOT .COM VULCANO T ermodomésticos S.A. Estrada de Cacia 3800 Cacia - PORTUGAL Recycled paper techsupport@cechot.com GA S LINE SIZE Natural Gas Nominal Iron Pipe Size* 1/2&qu ...

メーカー AquaStar カテゴリー Water Heater

AquaStar 125B LPSのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 125B LPSの取扱説明書
- AquaStarの製品カード
- パンフレット
- またはAquaStar 125B LPSの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、AquaStar 125B LPSの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、AquaStar 125B LPSの取り付け説明書、サービスマニュアル、簡易説明書、またはAquaStar 125B LPSのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、AquaStar 125B LPSの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

AquaStar 125B LPSデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAquaStar 125B LPSを使用するのを助ける技術的文書のことです。説明書は通常、全てのAquaStar 125B LPSユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

AquaStarの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. AquaStar 125B LPSの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAquaStar 125B LPSの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。AquaStar 125B LPSに関してこのドキュメントで見つけることができる全てのヒントの目次
3. AquaStar 125B LPSデバイスの基本機能を使うにあたってのヒント。 AquaStar 125B LPSのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。AquaStar 125B LPSに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAquaStar 125B LPSのメーカー/サービスへの連絡先に関する情報。

AquaStar 125B LPSについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAquaStar 125B LPSの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAquaStar 125B LPSで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)