    W ARNING : Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer , service agency or the gas supplier . Upon completion of the installation, these instructions should be handed to the user of the applianc ...

  • AquaStar 125B LPS - page 2

    ...

  • AquaStar 125B LPS - page 3

    3 ...

  • AquaStar 125B LPS - page 4

    4 PROPER LOCA TION FOR INST ALLING YOUR HEA TER Carefully select the location of your new heater . For your safety and for proper heater operation, you must provide an abundant supply of combustion air and a proper venting installation. The heater may still operate even when improperly vented. It will, however , be less efficient and could eventual ...

  • AquaStar 125B LPS - page 5

    5 COMBUSTION AIR REQUIREMENTS Observe the following instructions concerning combustion air . Appliances located in unconfined spaces: a) An unconfined space is one whose volume is greater than 50 cubic feet per 1000 Btu per hour of the combined rating of all appliances installed in the space. That would be 5850 cubic feet for the AquaStar 125B “S ...

  • AquaStar 125B LPS - page 6

    6 Fig. 3 - Flue Adaptor for High Altitude Installations 5” X 6” ADAPTOR USED ON HIGH AL TITUDE MOUNTING INST ALLA TION The Aquastar 125 B “S” is design certified for mounting on a wall. Do not install this appliance on a carpeted wall or over floor covering which is combustible, such as carpet. The heater must be mounted on a wall using app ...

  • AquaStar 125B LPS - page 7

    7 W ARNING : Failure TO INCREASE THE VENT SIZE TO SIX INCHES AND/or assure that the manifold pressure is set to proper value listed for applications at high altitudes will cause unsafe venting, asphyxiation, and will void IAS Certification. GAS CONNECTIONS and Gas Regulator Before connecting the gas supply , check the rating plate on the right side ...

  • AquaStar 125B LPS - page 8

    8 FOR YOUR SAFETY READ BEFORE LIGHTING THE PILOT W arning : If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life A. This appliance has a piezo-igniter for lighting the pilot burner . When lighting the pilot, follow these instructions exactly . B. BEFORE LIGHTING sm ...

  • AquaStar 125B LPS - page 9

    9 INFORMA TION ABOUT W A TER TEMPERA TURE The AquaStar 125B LPS and 125B NGS water heaters have a gas control that modulates burner output in response to water flow . Its purpose is to ensure that the hot water temperature will remain steady , although the water flow demand might vary (down to 1/2 gal/minute). The AquaStar 125 B”S” will produce ...

  • AquaStar 125B LPS - page 10

    10 TROUBLE SHOOTING Introduction The AquaStar 125 B “S” burners are activated by a water flow valve. Numerous water related problems can cause this water valve to malfunction such as: Insufficient water flow volume to activate the burners at its minimum flow requirement; Dirt in the water flow valve causing it to malfunction; Sediment build-up ...

  • AquaStar 125B LPS - page 11

    11 BURNERS DO NOT IGNITE WHEN HOT W A TER IS TURNED ON 1. Pilot is not on. Light the pilot. See lighting instructions. 2. Gas valve button not positioned on Burner Position Be sure once the pilot flame is on, that after a 15 to 20 second wait, the main burner button ( ) is pushed all the way in. 3. Cold incoming water connection made to wrong side ...

  • AquaStar 125B LPS - page 12

    12 the AquaStar ’s outlet pipe with your hand) and at the tap. If these two are very different, check for mixing valve or plumbing crossover (see “MAIN BURNERS WILL NOT IGNITE...” paragraph #6). 6. Parts in water flow valve are corroded so that the gas passage is not fully opening. Contact your service person or Controlled Energy . HOT W A TE ...

  • AquaStar 125B LPS - page 13

    13 ...

  • AquaStar 125B LPS - page 14

    14 AQ 125 BS Fig. 1 1 - INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST ...

  • AquaStar 125B LPS - page 15

    15 Fig. 1 1 INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST 125BS 1 Cover 8 705 421 033 2 Cap cover 8 703 304 01 1 3 Panel back 8 705 402 164 4 Draft divertor 8 705 505 354 5 Heat exchanger 8 705 406 189 6 Hot water pipe 8 700 705 431 7 Cold water pipe 8 700 705 294 8 Heat exchanger washer 8 710 103 045 9 Overheat sensor (ECO) 8 707 206 017 10 Main bur ...

  • AquaStar 125B LPS - page 16

    Replacement Parts available from North American Distributor CONTROLLED ENERGY CORP . 340 Mad River Park V ermont 05673 (U.S.A.) Phone 800-642-31 1 1 Fax (802) 496-6924 WWW .CECHOT .COM VULCANO T ermodomésticos S.A. Estrada de Cacia 3800 Cacia - PORTUGAL Recycled paper techsupport@cechot.com GA S LINE SIZE Natural Gas Nominal Iron Pipe Size* 1/2&qu ...

Производитель AquaStar Категория Water Heater

Документы, которые мы получаем от производителя устройства AquaStar 125B LPS мы можем разделить на несколько групп. Это в частности:
- технические чертежи AquaStar
- инструкции обслуживания 125B LPS
- паспорта изделия AquaStar
- информационные брошюры
- энергетические этикетки AquaStar 125B LPS
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания AquaStar 125B LPS.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа AquaStar 125B LPS, инструкции обслуживания, короткие инструкции или инструкции пользователя AquaStar 125B LPS. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия AquaStar 125B LPS.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства AquaStar 125B LPS, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании AquaStar 125B LPS пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей AquaStar 125B LPS.

Полная инструкция обслуживания AquaStar, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией AquaStar 125B LPS - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания AquaStar 125B LPS, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся AquaStar 125B LPS, которое найдем в данном документе
3. Советы по использованию основных функций устройства AquaStar 125B LPS - которые должны облегчить нам первые шаги во время использования AquaStar 125B LPS
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем AquaStar 125B LPS
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра AquaStar 125B LPS в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся AquaStar 125B LPS?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с AquaStar 125B LPS, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с AquaStar 125B LPS со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)