  • AquaStar 125B LPS - page 1

    W ARNING : Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer , service agency or the gas supplier . Upon completion of the installation, these instructions should be handed to the user of the applianc ...

  • AquaStar 125B LPS - page 2

    ...

  • AquaStar 125B LPS - page 3

    3 ...

  • AquaStar 125B LPS - page 4

    4 PROPER LOCA TION FOR INST ALLING YOUR HEA TER Carefully select the location of your new heater . For your safety and for proper heater operation, you must provide an abundant supply of combustion air and a proper venting installation. The heater may still operate even when improperly vented. It will, however , be less efficient and could eventual ...

  • AquaStar 125B LPS - page 5

    5 COMBUSTION AIR REQUIREMENTS Observe the following instructions concerning combustion air . Appliances located in unconfined spaces: a) An unconfined space is one whose volume is greater than 50 cubic feet per 1000 Btu per hour of the combined rating of all appliances installed in the space. That would be 5850 cubic feet for the AquaStar 125B “S ...

  • AquaStar 125B LPS - page 6

    6 Fig. 3 - Flue Adaptor for High Altitude Installations 5” X 6” ADAPTOR USED ON HIGH AL TITUDE MOUNTING INST ALLA TION The Aquastar 125 B “S” is design certified for mounting on a wall. Do not install this appliance on a carpeted wall or over floor covering which is combustible, such as carpet. The heater must be mounted on a wall using app ...

  • AquaStar 125B LPS - page 7

    7 W ARNING : Failure TO INCREASE THE VENT SIZE TO SIX INCHES AND/or assure that the manifold pressure is set to proper value listed for applications at high altitudes will cause unsafe venting, asphyxiation, and will void IAS Certification. GAS CONNECTIONS and Gas Regulator Before connecting the gas supply , check the rating plate on the right side ...

  • AquaStar 125B LPS - page 8

    8 FOR YOUR SAFETY READ BEFORE LIGHTING THE PILOT W arning : If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life A. This appliance has a piezo-igniter for lighting the pilot burner . When lighting the pilot, follow these instructions exactly . B. BEFORE LIGHTING sm ...

  • AquaStar 125B LPS - page 9

    9 INFORMA TION ABOUT W A TER TEMPERA TURE The AquaStar 125B LPS and 125B NGS water heaters have a gas control that modulates burner output in response to water flow . Its purpose is to ensure that the hot water temperature will remain steady , although the water flow demand might vary (down to 1/2 gal/minute). The AquaStar 125 B”S” will produce ...

  • AquaStar 125B LPS - page 10

    10 TROUBLE SHOOTING Introduction The AquaStar 125 B “S” burners are activated by a water flow valve. Numerous water related problems can cause this water valve to malfunction such as: Insufficient water flow volume to activate the burners at its minimum flow requirement; Dirt in the water flow valve causing it to malfunction; Sediment build-up ...

  • AquaStar 125B LPS - page 11

    11 BURNERS DO NOT IGNITE WHEN HOT W A TER IS TURNED ON 1. Pilot is not on. Light the pilot. See lighting instructions. 2. Gas valve button not positioned on Burner Position Be sure once the pilot flame is on, that after a 15 to 20 second wait, the main burner button ( ) is pushed all the way in. 3. Cold incoming water connection made to wrong side ...

  • AquaStar 125B LPS - page 12

    12 the AquaStar ’s outlet pipe with your hand) and at the tap. If these two are very different, check for mixing valve or plumbing crossover (see “MAIN BURNERS WILL NOT IGNITE...” paragraph #6). 6. Parts in water flow valve are corroded so that the gas passage is not fully opening. Contact your service person or Controlled Energy . HOT W A TE ...

  • AquaStar 125B LPS - page 13

    13 ...

  • AquaStar 125B LPS - page 14

    14 AQ 125 BS Fig. 1 1 - INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST ...

  • AquaStar 125B LPS - page 15

    15 Fig. 1 1 INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST 125BS 1 Cover 8 705 421 033 2 Cap cover 8 703 304 01 1 3 Panel back 8 705 402 164 4 Draft divertor 8 705 505 354 5 Heat exchanger 8 705 406 189 6 Hot water pipe 8 700 705 431 7 Cold water pipe 8 700 705 294 8 Heat exchanger washer 8 710 103 045 9 Overheat sensor (ECO) 8 707 206 017 10 Main bur ...

  • AquaStar 125B LPS - page 16

    Replacement Parts available from North American Distributor CONTROLLED ENERGY CORP . 340 Mad River Park V ermont 05673 (U.S.A.) Phone 800-642-31 1 1 Fax (802) 496-6924 WWW .CECHOT .COM VULCANO T ermodomésticos S.A. Estrada de Cacia 3800 Cacia - PORTUGAL Recycled paper techsupport@cechot.com GA S LINE SIZE Natural Gas Nominal Iron Pipe Size* 1/2&qu ...

Manufacturer AquaStar Category Water Heater

Documents that we receive from a manufacturer of a AquaStar 125B LPS can be divided into several groups. They are, among others:
- AquaStar technical drawings
- 125B LPS manuals
- AquaStar product data sheets
- information booklets
- or energy labels AquaStar 125B LPS
All of them are important, but the most important information from the point of view of use of the device are in the user manual AquaStar 125B LPS.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals AquaStar 125B LPS, service manual, brief instructions and user manuals AquaStar 125B LPS. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product AquaStar 125B LPS.

Similar manuals

A complete manual for the device AquaStar 125B LPS, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use AquaStar 125B LPS by users. Manuals are usually written by a technical writer, but in a language understandable to all users of AquaStar 125B LPS.

A complete AquaStar manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual AquaStar 125B LPS - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the AquaStar 125B LPS, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the AquaStar 125B LPS, that we can find in the current document
3. Tips how to use the basic functions of the device AquaStar 125B LPS - which should help us in our first steps of using AquaStar 125B LPS
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with AquaStar 125B LPS
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of AquaStar 125B LPS in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning AquaStar 125B LPS?

Use the form below

If you did not solve your problem by using a manual AquaStar 125B LPS, ask a question using the form below. If a user had a similar problem with AquaStar 125B LPS it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)