AB Soft MS6 SERIESの取扱説明書

14ページ 0.07 mb
ダウンロード

ページに移動 of 14

Summary
  • AB Soft MS6 SERIES - page 1

    Opal Pro to Mod TCP Page 1 Opal Pro MS6 SER IES AB Ethernet I P Interface Users Manual Revision 1.00 ...

  • AB Soft MS6 SERIES - page 2

    Opal Pro to Mod TCP Page 2 ...

  • AB Soft MS6 SERIES - page 3

    Opal Pro to Mod TCP Page 3 FOR YOUR SAFETY Only qualified personnel shoul d install this equipment, after first reading and understanding all the information in this manual. All instructions should be strictly adhered to. The user should consult Brock Solutions or a SAF OPAL Starters supplier for clarification of the contents of t his manual should ...

  • AB Soft MS6 SERIES - page 4

    Opal Pro to Mod TCP Page 4 ...

  • AB Soft MS6 SERIES - page 5

    Opal Pro to Mod TCP Page 5 Table of Conten ts INTRODUCTION .............................................................................................. 6 HARDWARE .................................................................................................... 6 JUMPER SET TINGS ................................................................. ...

  • AB Soft MS6 SERIES - page 6

    Opal Pro to Mod TCP Page 6 Opal Pro to Mod TC P Introduction The Opal Pro can be m onitored and controlled over an Ethernet communication network using the AB Ethernet IP pr otocol. The Opal Pro connects to the Ether net network through and optional Ethernet card that is mounted on the m ain Opal Pro control car d (CA530). Access is g ained to the ...

  • AB Soft MS6 SERIES - page 7

    Opal Pro to Mod TCP Page 7 LED Indicators Two bi-colour (red/green) LED indicators are mount ed beside the network connector. The upper LED indicates the Ethernet interface card stat us. LED State Ethernet Interface Card Status OFF No power Flashing Red Recoverable configuration fault ( card is not configured, contact Br ock Solutions for support) ...

  • AB Soft MS6 SERIES - page 8

    Opal Pro to Mod TCP Page 8 Op al Pro Paramete r Settings The parameters in t he Opal Pro used to con figure the Ehernet inter face card (group 14) ar e only accessible if a Ethernet interface card is inst alled. The parameter sett ings are as follows: Opal Pro Parameter Setting Description 2.02 Comm Module Ethernet Type of interface car d installed ...

  • AB Soft MS6 SERIES - page 9

    Opal Pro to Mod TCP Page 9 15.04 Comm Fault Enable Disable Enable – Opal Pro trips out on a communication fault Disable – Nothing happens on a communication fault 15.05 Comm Fault Time 0.1 to 5.0 secs This is the time sett ing that the Opal Pro uses to detect a communication fault. Bit 15 of the command word must change state twice with in the ...

  • AB Soft MS6 SERIES - page 10

    Opal Pro to Mod TCP Page 10 I/O Configuration The Opal Pro supports 4 input words and 51 output words. Their description is as follows: Input Words (Polled) AB Ethernet IP Name Description Bit 0 – Run Command Bit 1 – Jog Command Bit 2 – Reverse Comm and Bit 3 – Reset Command Bit 4 – DCI/Soft Stop Enable Bit 5 – Reserved Bit 6 – Reserv ...

  • AB Soft MS6 SERIES - page 11

    Opal Pro to Mod TCP Page 11 Output Words (Polled) AB Ethernet IP Name Description Bit 0 – Ready to Run (dr ive is enable and has 3 phase power) Bit 1 –Running (start is regulating) Bit 2 – Full On (star ter is phased fully on) Bit 3 – Up to Speed (st arted is phased fully on and the curr ent is below 105% of nameplate cur rent as set in 13. ...

  • AB Soft MS6 SERIES - page 12

    Opal Pro to Mod TCP Page 12 Relay Status Status of the Relay O utputs Bit 0 – Running Bit 1 – By-Pass Bit 2 – Shorted SCR Bit 3 – Reverse 1.07 Input Word 9 Bit 4 – Faulted 1.08 Input Word 10 Analog Output Analog Output value in Volts X 100 2.01 Input Word 11 Stack Size Opal Pro Stack Size in Amps 2.02 Input Word 12 Comm Module Type 0 – ...

  • AB Soft MS6 SERIES - page 13

    Opal Pro to Mod TCP Page 13 12.01 Input Word 27 Analog Output 16 = Current Refer ence 17 = Current Feedback 18 = Overload level 19 = Phase Angle 13.01 Input Word 28 Motor Amps Motor nameplate cur rent in Amps 13.02 Input Word 29 Motor Volts Motor nameplat e volts in Volts 13.03 Input Word 30 Service Factor Motor nameplate ser vice factor x 100 14.0 ...

  • AB Soft MS6 SERIES - page 14

    Opal Pro to Mod TCP Page 14 NOTE: The Opal Pro must have firmw are version 1.70 or higher. ...

メーカー AB Soft カテゴリー Network Card

AB Soft MS6 SERIESのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- MS6 SERIESの取扱説明書
- AB Softの製品カード
- パンフレット
- またはAB Soft MS6 SERIESの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、AB Soft MS6 SERIESの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、AB Soft MS6 SERIESの取り付け説明書、サービスマニュアル、簡易説明書、またはAB Soft MS6 SERIESのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、AB Soft MS6 SERIESの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

AB Soft MS6 SERIESデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAB Soft MS6 SERIESを使用するのを助ける技術的文書のことです。説明書は通常、全てのAB Soft MS6 SERIESユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

AB Softの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. AB Soft MS6 SERIESの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAB Soft MS6 SERIESの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。AB Soft MS6 SERIESに関してこのドキュメントで見つけることができる全てのヒントの目次
3. AB Soft MS6 SERIESデバイスの基本機能を使うにあたってのヒント。 AB Soft MS6 SERIESのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。AB Soft MS6 SERIESに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAB Soft MS6 SERIESのメーカー/サービスへの連絡先に関する情報。

AB Soft MS6 SERIESについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAB Soft MS6 SERIESの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAB Soft MS6 SERIESで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)