Standard Horizon DS41の取扱説明書

17ページ 0.32 mb
ダウンロード

ページに移動 of 17

Summary
  • Standard Horizon DS41 - page 1

    DS41 Digital Depth Sounder Owner’ s Manual Standard 2 Inch Installation Dual Station Operation NMEA Repeater Reads in Feet Fathoms or Meters Adjustable Prop or Surface Offset Shallow and Deep alarms Dual Station Operation ...

  • Standard Horizon DS41 - page 2

    DS41 Owner’s Manual DS41 Owner’s Manual DS41/HS/2G Contents Specifications ................................................................................................................. 2 Operation ...................................................................................................................... .. 3 Alarms .............. ...

  • Standard Horizon DS41 - page 3

    DS41 Owner’s Manual 2 Specifications • Size Mount 2" (51mm) diameter hole Depth behind face plate 3.75" (95mm) max. Display 3-character LCD • Color Black with texture on bezel. • Backlighting Red colored diffused lighting for displa y . • Water Integrity F ront will withstand direct water spra y . • Depth/Alarm Range 2.0 ! 600 ...

  • Standard Horizon DS41 - page 4

    DS41 Owner’s Manual 3 Operation Whenever power is applied the depth sounder is active and water depth is displayed. If the sonar signal does not show a bottom the display will indicate “- -”. This can occur if the water is aerated or the maximum depth is exceeded. Note: The maximum depth decreases as boat speed increases. Alarms T wo types of ...

  • Standard Horizon DS41 - page 5

    DS41 Owner ’ s Manual 4 Deep Alarm T o set the deep alar m: 1. Press the # ke y for three seconds. The display will show: dAL OFF OFF ON ^ V V 2. After two seconds the display will indicate the current Deep Alarm depth setting. 8 8 50 3. Use the " and # keys to change the value. If either key is held depressed for more than one second the re ...

  • Standard Horizon DS41 - page 6

    DS41 Owner ’ s Manual 5 4. Use the " and # keys to change the value. If either key is held depressed for more than one second the reading will increase or decrease rapidly . 5. The offset can be programmed in 0.1 unit steps from -9.9 ! 9.9 feet (or equivalent). When programmed f or a negative offset, ‘ - ’ will be indicated on the left h ...

  • Standard Horizon DS41 - page 7

    DS41 Owner ’ s Manual 6 T roubleshooting No display: 1. Check DC po wer connections and DC polar ity with voltmeter . 2. Check fuse. No depth reading ( ## ## ## ## ## ) at all depths: 1. Check transducer for growth or multiple coats of paint. 2. Check the transducer cable for cuts and sharp bends. 3. Check that the transducer connection behind th ...

  • Standard Horizon DS41 - page 8

    DS41 Owner ’ s Manual 7 What comes with your Digital Depth Sounder Standard Mounting Bracket ................................................................. With mounting hardware Extension P ower Cord ......................... 6 feet long with quick-disconnect connectors T wist Lock F ace Plate ................................................. ...

  • Standard Horizon DS41 - page 9

    DS41 Owner ’ s Manual 8 2.75" 2.125" 13 ° Note: All transducers come with 30 feet of cable. Replacement Parts The follo wing par ts may be ordered from the P ar ts Depar tment. T o order , call T oll-free Number: 1-800-487-2788. Square F ace Plate ............................................................ Part Number 568001012A Round ...

  • Standard Horizon DS41 - page 10

    DS41 Owner ’ s Manual 9 Installation Face Plate Installation 1. T o install a face plate: a ) Attach the face plate to the front panel of the instrument. b ) T wist the face plate cloc kwise until tight. 2. T o remov e f ace plate, twist it anticlockwise until loose and detach. Instrument Installation The instrument can be easily installed in dif ...

  • Standard Horizon DS41 - page 11

    DS41 Owner ’ s Manual 10 6. Connect the power cord at the back of the instrument to a 12 V power supply which is active whenever the ignition switch is on. The red lead should be connected to the positive terminal of the power supply via a 1 amp fuse or a 1 amp circuit breaker . The black lead should be connected to the negative terminal. Figure ...

  • Standard Horizon DS41 - page 12

    DS41 Owner ’ s Manual 11 T ransducer Installation Note: The installation of a transducer is a job for a professional boat yard that performs numerous installations. The following is an informational guide- line on the installation of transducers. General Correct installation of the transducer is essential for optimum operation of the instrument. ...

  • Standard Horizon DS41 - page 13

    DS41 Owner ’ s Manual 12 Sailboats On sailboats, the transducer should be mounted where the acoustic beam will not be shaded by the keel. A spot forward of the keel is usually best. T ry to find an accessible spot with a minimum deadrise angle. See Figure 4. Powerboats On IO ’ s transducers mounted close to the engine usually yield good results ...

  • Standard Horizon DS41 - page 14

    DS41 Owner ’ s Manual 13 RUBBER GROMMET SEAL CAP OIL DEADRISE ANGLE CUT PVC PIPE TRANSDUCER Figure 7. In-Hull Installation In-Hull Installation T ransducer installation inside a solid fiberglass hull ma y degrade perf or mance of depth sounder. Therefore, this type of installation is not preferred over thru-hull and transom installations. Should ...

  • Standard Horizon DS41 - page 15

    DS41 Owner ’ s Manual 14 Multiple DS41 instruments can be installed on a single vessel. These instr uments can be connected together and configured to operate in a dual station configuration. One instrument is designated as a master and all other instruments, connected to it, are configured as slav es. The master device is connected to the depth ...

  • Standard Horizon DS41 - page 16

    DS41 Owner ’ s Manual 15 4. Continue to hold the # key until the display indicates the current linked/ separate selection. Linked Separate 5. Use the " and # keys to change the selection. 6. T o exit this mode , press and hold both the " and # k eys sim ultaneously . Alternatively , if no keys are pressed f or a period of 5 seconds norm ...

  • Standard Horizon DS41 - page 17

    DS41 Owner ’ s Manual 16 The DS41 can be configured to operate as a NMEA repeater . In this mode it will display depth information from any depth sounder outputing DPT or DBT NMEA depth data (no other NMEA depth sentences are supported). Notes: 1 ) The only information displayed from the DPT and DBT sentence is depth below the transducer . The us ...

メーカー Standard Horizon カテゴリー SONAR

Standard Horizon DS41のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DS41の取扱説明書
- Standard Horizonの製品カード
- パンフレット
- またはStandard Horizon DS41の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Standard Horizon DS41の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Standard Horizon DS41の取り付け説明書、サービスマニュアル、簡易説明書、またはStandard Horizon DS41のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Standard Horizon DS41の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Standard Horizon DS41デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがStandard Horizon DS41を使用するのを助ける技術的文書のことです。説明書は通常、全てのStandard Horizon DS41ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Standard Horizonの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Standard Horizon DS41の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははStandard Horizon DS41の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Standard Horizon DS41に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Standard Horizon DS41デバイスの基本機能を使うにあたってのヒント。 Standard Horizon DS41のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Standard Horizon DS41に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるStandard Horizon DS41のメーカー/サービスへの連絡先に関する情報。

Standard Horizon DS41についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもStandard Horizon DS41の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがStandard Horizon DS41で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください