    FIELDPOINT ™ OPERATING INSTRUCTIONS AND SPECIFICATIONS FP-DO-403 and cFP-DO-403 16-Channel, 5 to 30 V Sinking Digit al Output Module These operating instructions descri be ho w to install and use the National Instruments FP-DO-403 a nd cFP-DO-40 3 digital output modules, referred to inclusi v ely as the [c]FP-DO-403. F or information about config ...

  • National Instruments cFP-DO-403 - page 2

    [c]FP-DO-403 2 ni.com 2. Align the FP-DO-403 alignment slots with the guide rails o n the terminal base. 3. Press firmly to seat the FP-DO-403 on the terminal base. When the module is firmly seated, the te rminal base latch locks it into place. Figure 1. Installing the FP-DO-403 Installing the cFP-DO-403 The cFP-DO-403 mounts on a Compact FieldPoin ...

  • National Instruments cFP-DO-403 - page 3

    © National Instruments Corp. 3 [c]FP-DO-403 Figure 2. Installing the cFP-DO-403 Wiring the [c]FP-DO-403 The FP-TB- x terminal base has conne ctions for each FP-DO-403 output channel and for an external supply to po wer field devices. The cFP-CB- x connector block provides the same connections for the cFP-DO-403. Each channel has one output termina ...

  • National Instruments cFP-DO-403 - page 4

    [c]FP-DO-403 4 ni.com loads on the output channels, up to 2 A per channel. 1 Connect the external po wer supply to multiple V and V SUP terminals and to multiple C and COM terminals as need ed to ensure that the maximum current through any terminal is 2 A or less. Install a 2 A maximum, fast-act ing fuse (F2A 250V) between the external po wer suppl ...

  • National Instruments cFP-DO-403 - page 5

    © National Instruments Corp. 5 [c]FP-DO-403 Figure 3. Wiring for Low-Current Applica tions Wiring for High-Current Applications If your application requires more than 2 A combined current through all channels of the [c]F P-DO-403, wire your application as shown in Figure 4. Install a 2 A maximum, f ast-acting fuse (F2A 250V) in series with each lo ...

  • National Instruments cFP-DO-403 - page 6

    [c]FP-DO-403 6 ni.com Digital Output Circuit The [c]FP-DO-403 digital output ch annels are optically isolated from the rest of the FieldPoint bank . In the ON state, a transistor is turned on between the V OUT terminal and the ex ternal supply (the C and COM terminals). In the OFF stat e, this transistor is turned of f, allowing only a smal l leaka ...

  • National Instruments cFP-DO-403 - page 7

    © National Instruments Corp. 7 [c]FP-DO-403 mount the flyback diode within 18 in. of the load. Figure 5 shows a flyback diode connected to an inductiv e load. Figure 5. Connection to Inductive Load with Flyback Diode Although the [c]FP-DO-403 contains flyback diodes to pre vent excessi vely high voltage from damaging the module, National Instrumen ...

  • National Instruments cFP-DO-403 - page 8

    [c]FP-DO-403 8 ni.com 250 V rms Measurement Cate gory II contin uous isolation, ve rified by 2,300 V rms , 5 s dielectric withst and test. The [c]FP-DO-403 provides double insulation (compliant with IEC 61010-1) for working v oltages of 250 V rms 1 . Safety standards (such as those published by UL and IEC) requir e the use of double insulation betw ...

  • National Instruments cFP-DO-403 - page 9

    © National Instruments Corp. 9 [c]FP-DO-403 •D o not use the [c]FP-DO-403 as the only isolating barrier between human cont act and working v o ltages higher than 250 V rms . • Operate the [c]FP-DO-403 only at or belo w Pollution Degree 2. Pollution De gree 2 means that only nonconductive pollution occurs in most case s. Occasionally , ho wever ...

  • National Instruments cFP-DO-403 - page 10

    [c]FP-DO-403 10 ni.com Caution For Zone 2 applications, install a protection device across the e xternal power supply and the COM terminal. The device must pre vent the external po wer supply voltage from e xceeding 42 V if there is a transient ov ervoltage conditi on. Special Conditions for Hazard ous Locations Use in Europe The [c]FP-DO-403 has b ...

  • National Instruments cFP-DO-403 - page 11

    © National Instruments Corp. 11 [c]FP-DO-403 Power Requirements Power from network module ............ 600 mW Safety Isolat ion Voltage Isolation voltage is v erified by a dielectric withstand te st. Channel to ground Continuous .............. ......... .......... 250 V rms , Measurement Category II Dielectric withstand... ......... ........ 2 ,30 ...

  • National Instruments cFP-DO-403 - page 12

    [c]FP-DO-403 12 ni.com Safety This product is designed to meet the requirements of the following standards of safety for electric al equipment for measurement, control, and laboratory use: • IEC 61010-1, EN-61010-1 • UL 61010-1, CSA 61010-1 Note For UL and other safety certif ications, refer to the product label or visit ni.com/certification , ...

  • National Instruments cFP-DO-403 - page 13

    © National Instruments Corp. 13 [c]FP-DO-403 contains the en vironmental regulat ions and directi v es with which NI complies, as well as othe r en vironmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of their lif e cycle, all products must be sent to a WEEE re c ycling cen ...

  • National Instruments cFP-DO-403 - page 14

    [c]FP-DO-403 14 ni.com Where to Go for Support For more information about settin g up the FieldPoint system, refer to these National Instruments documents: • FieldPoint network module user manual • Other FieldPo int I/O m odule operating instructions • FieldPoint terminal base and connector block operating instructions Go to ni.com/support fo ...

  • National Instruments cFP-DO-403 - page 15

    © 2002–2007 Nati onal Instruments Corp. All rights reserved. 373354C-01 Aug07 National Instruments, NI, n i.com, and LabVIEW are trademarks of National I nstruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments tra demarks. Other product and company names ment ioned herein are trad ...

メーカー National Instruments カテゴリー Network Router

National Instruments cFP-DO-403のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- cFP-DO-403の取扱説明書
- National Instrumentsの製品カード
- パンフレット
- またはNational Instruments cFP-DO-403の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、National Instruments cFP-DO-403の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、National Instruments cFP-DO-403の取り付け説明書、サービスマニュアル、簡易説明書、またはNational Instruments cFP-DO-403のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、National Instruments cFP-DO-403の製品を使用するにあたって最も人気のある説明書を閲覧できます。

National Instruments cFP-DO-403デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNational Instruments cFP-DO-403を使用するのを助ける技術的文書のことです。説明書は通常、全てのNational Instruments cFP-DO-403ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

National Instrumentsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. National Instruments cFP-DO-403の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNational Instruments cFP-DO-403の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。National Instruments cFP-DO-403に関してこのドキュメントで見つけることができる全てのヒントの目次
3. National Instruments cFP-DO-403デバイスの基本機能を使うにあたってのヒント。 National Instruments cFP-DO-403のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。National Instruments cFP-DO-403に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNational Instruments cFP-DO-403のメーカー/サービスへの連絡先に関する情報。

National Instruments cFP-DO-403についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNational Instruments cFP-DO-403の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNational Instruments cFP-DO-403で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)