  • Heat Controller 13 SEER - page 1

    SPLIT SYSTEM AIR CONDITIONER USER’S MANU AL / INST ALLA TION INSTR UCTIONS R-22, 13 SEER USER INFORMA TION IMPORT ANT SAFETY INFORMA TION ................. 2 OPERA TING INSTRUCTIONS ............................... 2 Cooling Operation ................................................. 2 Heating Operation ............................................ ...

  • Heat Controller 13 SEER - page 2

    2 IMPORT ANT SAFETY INFORMA TION Saf ety markings are used frequently throughout this manual to designate a degree or lev el of seriousness and should not be ignored. W ARNING indicates a potentially hazardous situation that if not av oided, could result in personal injur y or death. CA UTION indicates a potentially hazardous situation that if not ...

  • Heat Controller 13 SEER - page 3

    3 INST ALLER INFORMA TION IMPORT ANT SAFETY INFORMA TION INST ALLER: Please read all instructions before servicing this equipment. Pay attention to all safety warnings and any other special notes highlighted in the manual. Saf ety markings are used frequently throughout this manual to designate a degree or le v el of seriousness and should not be i ...

  • Heat Controller 13 SEER - page 4

    4 AIR CONDITIONER INST ALLA TION General Information Split system air conditioners are designed only f or outdoor rooftop or ground le v el installations. This unit has been tested f or capacity and efficiency in accordance with AHRI Standards and will provide man y years of saf e and dependable comf ort, providing it is properly installed and mai ...

  • Heat Controller 13 SEER - page 5

    5 Connecting Refrigerant T ubing Between the Indoor & Outdoor Unit CA UTION: This system uses R-22 refrigerant which may contain POE oil. When servicing, co ver or seal openings to minimize the exposure of the refrigerant system to air to prevent accum ulation of moisture and other contaminants. See page 8 for ad ditional info. After outdoor an ...

  • Heat Controller 13 SEER - page 6

    6 • The outdoor unit requires both power and control circuit electrical connections. Refer to the wiring diagram / schematic f or identification and location of outdoor unit field wiring interfaces (Figure 11, page 17). Make all electrical connections in accordance with all applicable codes and ordinances. • O ...

  • Heat Controller 13 SEER - page 7

    7 System Cooling 1. Set the ther mostat’ s system mode to COOL and the f an mode to A UT O. Gradually low er the ther mostat temperature setpoint belo w room temperature and v erify the outdoor unit and indoor blower energiz e. 2. V erify blow er wheel is spinning in direction indicated by arrow . Feel the air being circu lated by the indo or blo ...

  • Heat Controller 13 SEER - page 8

    8 CA UTION: The unit should never be operated without a filter in the return air system. Replace disposable filters with the same type and size. • Do not attempt to add additional oil to motors unequipped with oil tubes. The compressor is her metically sealed at the f actor y and does not require lubrication. REPLA ...

  • Heat Controller 13 SEER - page 9

    9 TXV COOLING CHARGING CHARTS 140 160 180 200 220 240 260 280 300 320 340 360 380 400 75 80 85 90 95 100 105 110 115 120 125 130 135 Liquid Te mperature (F ) Liquid Pressure (psig) Add re fr igerant w hen below curve Re mo ve re fr igerant w hen above curv e Figure 4. Char ging Char t f or 1.5 T on Units Figure 3. Unit Dimensions Unit Size (T on) H ...

  • Heat Controller 13 SEER - page 10

    10 Figure 5. Char ging Char t f or 2 T on Units (with Microchannel Coil) 140 160 180 200 220 240 260 280 300 320 340 360 380 400 75 80 85 90 95 100 105 110 115 120 125 130 135 Liquid Te mperature (F ) Liquid Pressure (psig) Add re fr igerant w hen below curve Re mo ve re fr igerant w hen above curv e Figure 6. Char ging Char t f or 2.5 T on Units ( ...

  • Heat Controller 13 SEER - page 11

    11 Figure 7. Char ging Char t f or 3 T on Units (with Microchannel Coil) 140 160 180 200 220 240 260 280 300 320 340 360 380 400 75 80 85 90 95 100 105 110 115 120 125 130 135 Liquid Te mperature (F ) Liquid Pressure (psig) Add re fr igerant w hen below curve Re mo ve re fr igerant w hen above curv e Figure 8. Char ging Char t f or 3.5 T on Units 1 ...

  • Heat Controller 13 SEER - page 12

    12 Figure 9. Char ging Char t f or 4 T on Units 140 160 180 200 220 240 260 280 300 320 340 360 380 400 75 80 85 90 95 100 105 110 115 120 125 130 135 Liquid Te mperature (F ) Liquid Pressure (psig) Add re fr igerant when below curve Re mo ve re fr igerant w hen above curv e Figure 10. Char ging Char t f or 5 T on Units 140 160 180 200 220 240 260 ...

  • Heat Controller 13 SEER - page 13

    13 FIGURES & T ABLES Shaded bo x es indicate flooded conditions. Rated design v alues. The suction pressure will v ar y from design v alue if indoor air flo w , entering dry bulb , or entering wet bulb temperatures are lo wer than design. 1. All pressures are listed in psig and all temperatures in ° F 2. Discharge temperatures greater than c ...

  • Heat Controller 13 SEER - page 14

    14 Shaded bo x es indicate flooded conditions. Rated design values . The suction pressure will v ar y from design v alue if indoor air flo w , entering dry bulb , or entering wet bulb temperatures are lo wer than design. 1. All pressures are listed in psig and all temperatures in ° F 2. Discharge temperatures greater than char ted v alues indica ...

  • Heat Controller 13 SEER - page 15

    15 Shaded bo x es indicate flooded conditions. Rated design values . The suction pressure will v ar y from design v alue if indoor air flo w , entering dry bulb , or entering wet bulb temperatures are lo wer than design. 1. All pressures are listed in psig and all temperatures in ° F 2. Discharge temperatures greater than char ted v alues indica ...

  • Heat Controller 13 SEER - page 16

    16 T able 10. Char ging T able for 5 T on Units Suct. Press. OUTDOOR TEMPERA TURE (° F) 70 75 80 85 90 95 100 105 Liq. Press. Dis. T emp. Liq. Press. Dis. T emp. Liq. Press. Dis. T emp. Liq. Press. Dis. T emp. Liq. Press. Dis. T emp. Liq. Press. Dis. T emp. Liq. Press. Dis. T emp. Liq. Press. Dis. T emp. 68 149 141 70 151 146 166 146 72 154 151 16 ...

  • Heat Controller 13 SEER - page 17

    17 Figure 11. Wiring Diagram Single Phase 1. Couper le courant av ant de f aire letretien. 2. Emplo yez uniquement des conducteurs en cuivr e. 3. Ne con vient pas aux installations de plus de 150 volt a la terre . 710570B (Replaces 710570A) 0109 WIRING DIA GRAM Split System Air Conditioner (Outdoor Section) NO TES: 1. Disconnect all power bef ore s ...

  • Heat Controller 13 SEER - page 18

    18 ...

  • Heat Controller 13 SEER - page 19

    19 ...

  • Heat Controller 13 SEER - page 20

    W ARRANTY INFORMA TION A warr anty cer tificate with full details is included with the air conditioner . Carefully re view these responsibilities with your dealer or service company . The manuf acturer will not be responsible f or an y costs f ound necessar y to correct problems due to improper setup , improper installation, adjustments, improper ...

Manufacturer Heat Controller Category Air Conditioner

Documents that we receive from a manufacturer of a Heat Controller 13 SEER can be divided into several groups. They are, among others:
- Heat Controller technical drawings
- 13 SEER manuals
- Heat Controller product data sheets
- information booklets
- or energy labels Heat Controller 13 SEER
All of them are important, but the most important information from the point of view of use of the device are in the user manual Heat Controller 13 SEER.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Heat Controller 13 SEER, service manual, brief instructions and user manuals Heat Controller 13 SEER. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Heat Controller 13 SEER.

A complete manual for the device Heat Controller 13 SEER, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Heat Controller 13 SEER by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Heat Controller 13 SEER.

A complete Heat Controller manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Heat Controller 13 SEER - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Heat Controller 13 SEER, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Heat Controller 13 SEER, that we can find in the current document
3. Tips how to use the basic functions of the device Heat Controller 13 SEER - which should help us in our first steps of using Heat Controller 13 SEER
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Heat Controller 13 SEER
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Heat Controller 13 SEER in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Heat Controller 13 SEER?

Use the form below

If you did not solve your problem by using a manual Heat Controller 13 SEER, ask a question using the form below. If a user had a similar problem with Heat Controller 13 SEER it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)