Manual Goodman Mfg GPC14H

32 pages 0.85 mb
Download

Go to site of 32

Summary
  • Goodman Mfg GPC14H - page 1

    SS-GPC14H www .goodmanmfg.com 7/11 Supersedes 6/11 Product Featur es • Energ y-efcientcompressor  withinternalrelief valve • EEMblowermotor • Quiethorizontaldischarge • Coppertube/aluminumncoil • T otall yenclosed,permanentlylubricated  condenserfanmotor ? ...

  • Goodman Mfg GPC14H - page 2

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 2 www .goodmanmfg.com SS-GPC14H n omenclA TURe Brand Engineering G Goodman Minor Revision or Distinctions™ Product Category Engineering P Packaged Unit Major Revision Type Voltage Designator H Heat Pump 1 208-230/1/60 C Air Conditioner 3 208-230/3/60 4 460/3/60 Efficiency Refrigerant 13 13 SEER ...

  • Goodman Mfg GPC14H - page 3

    P roduct S Pecifica tionS P roduct S Pecifica tionS SS-GPC14H www .goodmanmfg.com 3 S Pecifica tionS Models GPC14 24H41AC GPC14 30H41AA GPC14 30H41AC GPC14 36H41AA GPC14 36H41AC Cooling Cap acity Cooling Capacity (BTU/h) 24,600 28,400 28,400 35,600 35,600 Sensible BTU/h 18,200 21,600 21,600 27,100 27,100 SEER / EER 14.5 / 12.1 14.0 / 12.1 14.0 / 12 ...

  • Goodman Mfg GPC14H - page 4

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 4 www .goodmanmfg.com SS-GPC14H S PeciFicA TionS Models GPC14 42H41AA GPC14 42H41AC GPC14 48H41AA GPC14 48H41AC GPC14 60H41A* Cooling Cap acity Cooling Capacity (BTU/h) 40,000 40,000 46,500 46,500 57,500 Sensible BTU/h 30,400 30,400 35,300 35,300 40,800 SEER / EER 14.2 / 12.0 14.2 / 12.0 14.5 / 12 ...

  • Goodman Mfg GPC14H - page 5

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 5 A iRFl ow D A T A Model Speed V ol ts E.S.P . (In. of H₂O) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 GPC14 24H41** T1 230 CFM 934 759 755 638 581 489 - -   95 77 76 73 83 90 - - T2, T3 230 CFM 990 837 801 744 696 652 601 -   107 94 105 110 119 133 14 ...

  • Goodman Mfg GPC14H - page 6

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 6 www .goodmanmfg.com SS-GPC14H e xP AnDeD c ooling D A TA — gPc1 424H4 1Ac Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 920 MBh 24.1 25.0 27.4 - 23.5 24.4 26.7 - 23. ...

  • Goodman Mfg GPC14H - page 7

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 7 e xP AnDeD c ooling D A TA — gPc1 424H4 1Ac ( conT .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 920 MBh 25.0 25.5 27.2 29.1 24.4 24 ...

  • Goodman Mfg GPC14H - page 8

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 8 www .goodmanmfg.com SS-GPC14H e xP AnDeD c ooling D A TA — gPc1 430H4 1AA Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1180 MBh 27.8 28.8 31.6 - 27.2 28.2 30.9 - 26 ...

  • Goodman Mfg GPC14H - page 9

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 9 e xP AnDeD c ooling D A TA — gPc1 430H4 1AA ( conT .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1180 MBh 28.8 29.4 31.4 33.6 28.1 2 ...

  • Goodman Mfg GPC14H - page 10

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 10 www .goodmanmfg.com SS-GPC14H e xP AnDeD c ooling D A TA — gPc1 430H4 1Ac Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1145 MBh 27.8 28.8 31.6 - 27.2 28.2 30.9 - 2 ...

  • Goodman Mfg GPC14H - page 11

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 11 e xP AnDeD c ooling D A TA — gPc1 430H4 1Ac ( conT .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1145 MBh 28.8 29.4 31.4 33.6 28.1 ...

  • Goodman Mfg GPC14H - page 12

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 12 www .goodmanmfg.com SS-GPC14H e xP AnDeD c ooling D A TA — gPc1 436H4 1AA Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1349 MBh 34.9 36.2 39.6 - 34.1 35.3 38.7 - 3 ...

  • Goodman Mfg GPC14H - page 13

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 13 e xP AnDeD c ooling D A TA — gPc1 436H4 1AA ( conT .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1349 MBh 36.1 36.9 39.4 42.1 35.3 ...

  • Goodman Mfg GPC14H - page 14

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 14 www .goodmanmfg.com SS-GPC14H e xP AnDeD c ooling D A TA — gPc1 436H4 1Ac Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1350 MBh 35.8 37.1 40.7 - 35.0 36.3 39.8 - 3 ...

  • Goodman Mfg GPC14H - page 15

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 15 e xP AnDeD c ooling D A TA — gPc1 436H4 1Ac ( conT .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1350 MBh 37.1 37.9 40.5 43.3 36.2 ...

  • Goodman Mfg GPC14H - page 16

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 16 www .goodmanmfg.com SS-GPC14H Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1461 MBh 39.7 41.1 45.1 - 38.8 40.2 44.0 - 37.8 39.2 43.0 - 36.9 38.3 41.9 - 35.1 36.4 39. ...

  • Goodman Mfg GPC14H - page 17

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 17 Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1461 MBh 41.1 42.0 44.8 47.9 40.1 41.0 43.8 46.8 39.2 40.0 42.8 45.7 38.2 39.0 41.7 44.6 3 ...

  • Goodman Mfg GPC14H - page 18

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 18 www .goodmanmfg.com SS-GPC14H e xP AnDeD c ooling D A TA — gPc1 442H41A c Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1432 MBh 39.8 41.3 45.2 - 38.9 40.3 44.1 - 3 ...

  • Goodman Mfg GPC14H - page 19

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 19 e xP AnDeD c ooling D A TA — gPc1 442H41A c ( conT .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1432 MBh 41.2 42.1 45.0 48.1 40.2 ...

  • Goodman Mfg GPC14H - page 20

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 20 www .goodmanmfg.com SS-GPC14H e xP AnDeD c ooling D A TA — gPc1 448H41AA Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1800 MBh 45.6 47.2 51.7 - 44.5 46.1 50.5 - 43 ...

  • Goodman Mfg GPC14H - page 21

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 21 e xP AnDeD c ooling D A TA — gPc1 448H41AA ( conT .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1800 MBh 47.2 48.2 51.5 55.0 46.1 4 ...

  • Goodman Mfg GPC14H - page 22

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 22 www .goodmanmfg.com SS-GPC14H e xP AnDeD c ooling D A TA — gPc1 448H41A c Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1777 MBh 46.1 47.8 52.4 - 45.1 46.7 51.2 - 4 ...

  • Goodman Mfg GPC14H - page 23

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 23 e xP AnDeD c ooling D A TA — gPc1 448H41A c ( conT .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1777 MBh 47.7 48.8 52.1 55.7 46.6 ...

  • Goodman Mfg GPC14H - page 24

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 24 www .goodmanmfg.com SS-GPC14H e xP AnDeD c ooling D A TA — gPc1 460H41A * Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1800 MBh 56.3 58.4 64.0 - 55.0 57.0 62.5 - 5 ...

  • Goodman Mfg GPC14H - page 25

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 25 e xP AnDeD c ooling D A TA — gPc1 460H41A * ( conT .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper ature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 1800 MBh 58.3 59.6 63.7 68.1 57.0 ...

  • Goodman Mfg GPC14H - page 26

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 26 www .goodmanmfg.com SS-GPC14H H eA T k iT e lecTRicAl D AT A (B loweR o nl y , H eA T m oDe ) Model and Hea t Kit Usage Cir cuit #1 Circuit #2 A c tual kW / BTU@ 240V MCA¹ MOD² MCA¹ MOD² GPC1424H41* 1.5 / 1.5 -- -- -- -- HKR-05*, HKR-05C* 24 / 27 30 / 30 -- -- 4.75 / 16,200 HKR-08*, HKR-08C ...

  • Goodman Mfg GPC14H - page 27

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 27 D imenSionS m inimAl c leARAnceS A Dimensions Model Chassis Size Height GPC1424 GPC1430   GPC1436 GPC1442   GPC1448 GPC1460  38¾    A ...

  • Goodman Mfg GPC14H - page 28

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 28 www .goodmanmfg.com SS-GPC14H w iRing D iA gRAm — gPc1 42 4-60H4 1AA Wiring is subject to change. Always refer to the wiring diagram or the unitforthe mostup-to-datewiring . ⚠ W arninG High V oltage:  Disconnect all power bef ...

  • Goodman Mfg GPC14H - page 29

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 29 w iRing D iA gRAm — gPc1 42 4-48H4 1A c Wiring is subject to change. Always refer to the wiring diagram or the unitforthe mostup-to-datewiring . ⚠ W arninG High V oltage:  Disconnect all power be ...

  • Goodman Mfg GPC14H - page 30

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 30 www .goodmanmfg.com SS-GPC14H A cceSSoRieS Item Descrip tion OT /EHR18-60 Emergency Heat R elay kit OT18-60A Out door Thermostat Kit with Lock out Stat PCCP102/103 Roof Curb f or for Medium/Large Chassis PCE102/103 Downow Ec onomizer for f or Medium/Large Chassis PCEF102/103 Elbow & Flas ...

  • Goodman Mfg GPC14H - page 31

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS SS-GPC14H www .goodmanmfg.com 31 n o TeS ...

  • Goodman Mfg GPC14H - page 32

    P RoDUcT S PeciFicA TionS P RoDUcT S PeciFicA TionS 32 www .goodmanmfg.com SS-GPC14H Goodman Manufacturing Company , L.P ., reserves the right to discontinue, or change a t any time, specications or desig ns without notice or without incurring obligations. © 2011 • Goodman Manufacturing Company , L.P . • Houston, T exas • Printed in the U ...

Manufacturer Goodman Mfg Category Air Conditioner

Documents that we receive from a manufacturer of a Goodman Mfg GPC14H can be divided into several groups. They are, among others:
- Goodman Mfg technical drawings
- GPC14H manuals
- Goodman Mfg product data sheets
- information booklets
- or energy labels Goodman Mfg GPC14H
All of them are important, but the most important information from the point of view of use of the device are in the user manual Goodman Mfg GPC14H.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Goodman Mfg GPC14H, service manual, brief instructions and user manuals Goodman Mfg GPC14H. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Goodman Mfg GPC14H.

A complete manual for the device Goodman Mfg GPC14H, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Goodman Mfg GPC14H by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Goodman Mfg GPC14H.

A complete Goodman Mfg manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Goodman Mfg GPC14H - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Goodman Mfg GPC14H, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Goodman Mfg GPC14H, that we can find in the current document
3. Tips how to use the basic functions of the device Goodman Mfg GPC14H - which should help us in our first steps of using Goodman Mfg GPC14H
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Goodman Mfg GPC14H
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Goodman Mfg GPC14H in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Goodman Mfg GPC14H?

Use the form below

If you did not solve your problem by using a manual Goodman Mfg GPC14H, ask a question using the form below. If a user had a similar problem with Goodman Mfg GPC14H it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)