-
Scytek electronic 5000RS PLUS SERIES - page 1
5000RS P P LUS S S ERIES VEHICLE SECURITY SYSTEM WITH REMOTE START PRODUCT MANUAL ...
-
Scytek electronic 5000RS PLUS SERIES - page 2
L i m i t e d L L ifetime W W a r r a n t y This vehicle security system is warranted to the original purchaser , to be free from defects in material and workmanship. The manufacturer will repair or replace at its option, and free of charge for the first twelve (12) months, any part that proves defective in material or workmanship under normal inst ...
-
Scytek electronic 5000RS PLUS SERIES - page 3
1. About Y our System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 1 2. Remote T r ansmitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P age 2 Remote T r ansmitter Description . . . . . . . . . . . . . . . . . . . . ...
-
Scytek electronic 5000RS PLUS SERIES - page 4
...
-
Scytek electronic 5000RS PLUS SERIES - page 5
The ScyT ek Galaxy 5000RS Plus is a combination vehicle security and remote starting system f eaturing a built-in "ScyNet Network P ort" that allows direct connection of optional accessory modules and a PC interface off ering expanded system operation. With proper installation this system will pro vide superior protection and performance ...
-
Scytek electronic 5000RS PLUS SERIES - page 6
Standard Remote Transmitter Description The Galaxy 5000RS Plus is supplied with two 5-button R emote T ransmitters used to control system operations. Note : Using the optional PC or P ocket PC interface with the network softw are, it is possible to reconfigure the functionality of the tr ansmitter buttons. The standard (default) setting f or operat ...
-
Scytek electronic 5000RS PLUS SERIES - page 7
Adding/Replacing Transmitters T o replace lost or stolen transmit ters or to add additional transmit ters into the system, have all desired transmit ters ready and follow the steps below . Note : Up to 4 transmit ters can be programmed to oper ate the system. T o erase any previously stored transmit ter codes, be sure to program all 4 tr ansmitter ...
-
Scytek electronic 5000RS PLUS SERIES - page 8
Page 4 - Galaxy 5000RS Plus Optional 2-way LCD Remote Transmitter Description The Galaxy 5000RS Plus is compatible with the optional 2-way L CD remote transmitter , offering increased range and confirmation of an y activated f eatures. Button 1 Arms and Disarms the system and when held for 2 seconds, activ ates the system’ s Panic feature. Button ...
-
Scytek electronic 5000RS PLUS SERIES - page 9
Galaxy 5000RS Plus - Page 5 LCD Transmitter Battery Replacement Y our Galaxy Remote T ransmitter uses a 1.5 v olt AAA alkaline battery , which will require replacement in time. Depending on the amount of use, the battery may last up to six months bef ore it needs replacement. When the battery needs replacing, the system’ s operating range will de ...
-
Scytek electronic 5000RS PLUS SERIES - page 10
Page 6 - Galaxy 5000RS Plus Remote Arming The system monitors 6 independent areas ( zones ) while armed: doors, hood, trunk, shock sensor , optional sensor input, and the network port for future expansion. T o Arm the System: 1. T urn off the ignition. 2. Press Button 1. · The siren will chirp once.* · The doors will lock. · The parking lights w ...
-
Scytek electronic 5000RS PLUS SERIES - page 11
Galaxy 5000RS Plus - Page 7 Tamper Alert If the system was triggered while awa y , the LED will flash to indicate which zone triggered the system after disarming and turning on the ignition. The LED indication will repeat 8 times. LED Flashes (60 seconds): 1 flash = optional sensor 2 flashes = shock sensor 3 flashes = network based sensor 4 flashes ...
-
Scytek electronic 5000RS PLUS SERIES - page 12
Page 8 - Galaxy 5000RS Plus Panic Mode In the event of an emergency the tr ansmitter’ s remote P anic feature can be used to instantly trigger the alarm. T o activate the P anic Mode: 1. Press and hold Button 1 for 3 seconds. · The alarm will sound. · The parking lights will flash. · The doors will unlock* allowing access to the vehicle. 2. Pr ...
-
Scytek electronic 5000RS PLUS SERIES - page 13
Galaxy 5000RS Plus - Page 9 T o set the Emergency Override Code: 1. T urn on ignition. 2. Within 5 seconds, press the valet switch 5 times. · The siren will provide one long chirp, indicating that y ou have entered Progr amming. 3. Press the valet switch 4 times. · The siren will chirp each time the valet switch is pressed. 4. Within 5 seconds, p ...
-
Scytek electronic 5000RS PLUS SERIES - page 14
Page 10 - Galaxy 5000RS Plus Remote Starting T o Remote Start the S ystem: 1. Be sure the system is not in V alet Mode. 2. Press and hold Button 4 for three seconds. · The parking lights will turn on. · The LED will flash rapidly . · The engine will start and run for the dur ation of its programmed R un Time.* · The heater or air conditioner wi ...
-
Scytek electronic 5000RS PLUS SERIES - page 15
Galaxy 5000RS Plus - Page 11 Automatic Start Mode The Automatic Start Mode allows the vehicle to automatically start the vehicle ev ery one or two hours and run for the preset Run Time. T o turn on Auto Cold Starting: 1. T urn Ignition switch Off and wait f or 3 seconds. 2. T urn Ignition switch On and Off three times ending with Ignition in Of f p ...
-
Scytek electronic 5000RS PLUS SERIES - page 16
Page 12 - Galaxy 5000RS Plus E x t e n d e d F F e a t u r e s Ignition Door Locking F or added safety , the Ignition Door Locking f eature allows vehicles equipped with power door lock systems to automatically lock the doors when the ignition is turned on. If a door is open when the ignition is turned on, the Ignition Door Locking feature is disab ...
-
Scytek electronic 5000RS PLUS SERIES - page 17
Galaxy 5000RS Plus - Page 13 1. Thoroughly read and become familiar with the installation instructions bef ore beginning the installation. 2. R eview system contents: Main Unit T wo 5-Button Remote T ransmitters Siren Shock Sensor Harnesses • 6-Pin starter harness • 20-Pin main harness • 4-Pin shock sensor harness • 3-Pin door lock harness ...
-
Scytek electronic 5000RS PLUS SERIES - page 18
Page 14 - Galaxy 5000RS Plus Mounting the Control Unit The control unit must only be mounted in the interior of the vehicle. Do not mount the main unit in the engine compartment. Choose a mounting location that will not be easily accessible to a thief , and will not interfere with the oper ation of any vehicle components such as f oot pedals, steer ...
-
Scytek electronic 5000RS PLUS SERIES - page 19
Galaxy 5000RS Plus - Page 15 S y s t e m W W i r i n g 6-Pin Starter Harness Pin 1 RED WIRE A : Main Power Input A (+). Connect to the battery or constant power wire at the ignition switch with a minimum 30 Amp supply . R emo v e the fuse until the installation is complete and all wiring is check ed. Pin 2 RED WIRE B : Main Power Input B (+). Conne ...
-
Scytek electronic 5000RS PLUS SERIES - page 20
Page 16 - Galaxy 5000RS Plus Pin 9 BLACK WIRE : Ground Input (-). The B lack wire must connect to a solid chassis ground. Clean away any paint or dirt to insure the best possible ground. Pin 10 RED WIRE : Module Power Input (+). Connect to a constant source of +12V . Pin 11 VIOLET WIRE : Positiv e Door Input (+). Connect to the door switch circuit ...
-
Scytek electronic 5000RS PLUS SERIES - page 21
Galaxy 5000RS Plus - Page 17 Jumper Selection Carefully separ ate the top and bottom halves of the main unit case. Once the cov er is removed, the parking light polarity jumper will be visible next to the parking light relay . Set the jumper for the correct polarit y output as described below , then reassembly the main unit case. Parking Light Outp ...
-
Scytek electronic 5000RS PLUS SERIES - page 22
Page 18 - Galaxy 5000RS Plus Entering System Programming This system is compatible with both the optional LCD tr ansmit ter or the standard AM tr ansmitter , all system programming can be perf ormed using either one. T o enter System Progr amming: 1. T urn on ignition. 2. Within 5 seconds, press the valet switch 5 times. · The siren will provide o ...
-
Scytek electronic 5000RS PLUS SERIES - page 23
Galaxy 5000RS Plus - Page 19 5. Ignition Door Unlocking. Selects whether or not the system automatically unlocks the doors when the ignition is turned off . The Ignition Door Locking f eature may be programmed to unlock all doors or the driver’ s door only . If driver ’ s door only is selected, the optional Passenger Unlock wire must be connect ...
-
Scytek electronic 5000RS PLUS SERIES - page 24
Page 20 - Galaxy 5000RS Plus 10. Ignore Open Door Report. Bypasses the open zone warning chirps for vehicles equipped with a residual dome light circuit that remains on for a period of time after closing the door . 11. Aux 2 Auto Activate with Arm. When selected, the Auxiliary 2 output will activate when the system is armed. This feature can be use ...
-
Scytek electronic 5000RS PLUS SERIES - page 25
Galaxy 5000RS Plus - Page 21 FM module must be connected before completing this step. FM Remote Learn. Learns the optional 2-way FM tr ansmitter . Press Button 2 on the 1-wa y remote to enter FM T ransmitter learn mode, then press tr ansmitter But ton 1 on each FM remote (max 2). *Requires the optional ScyNet FM L CD P ager Module. 23. Ignition 2 R ...
-
Scytek electronic 5000RS PLUS SERIES - page 26
Page 22 - Galaxy 5000RS Plus W i r i n g D D i a g r a m s TO POSITIVE DOME LIGHT +12V Black/White (-) DOME LIGHT OUTPUT TO NEGATIVE DOME LIGHT +12V Black/White (-) DOME LIGHT OUTPUT P ositive Dome Light Negative Dome Light TO POSITIVE HORN WIRE +12V Brown/White (-) HORN OUTPUT TO NEGATIVE HORN WIRE +12V Brown/White (-) HORN OUTPUT P ositive Horn H ...
-
Scytek electronic 5000RS PLUS SERIES - page 27
Galaxy 5000RS Plus - Page 23 Negative T rigger P ositive T rigger R everse P olarity V acuum Adding Actuators F ollow the diagrams below f or connecting basic door lock systems. F or T wo Stage door lock systems (separately unlocks driv er and passenger doors) see following pages. D o o r L L o c k D D iagrams ...
-
Scytek electronic 5000RS PLUS SERIES - page 28
Page 24 - Galaxy 5000RS Plus T w o S S t a g e D D oor L L o c k D D i a g r a m s ...
-
Scytek electronic 5000RS PLUS SERIES - page 29
Galaxy 5000RS Plus - Page 25 T w o S S t a g e D D oor L L o c k D D iagrams c c o n t ’ d T wo Stage R everse P olarity ...
-
Scytek electronic 5000RS PLUS SERIES - page 30
Page 26 - Galaxy 5000RS Plus FCC ID: OARRXAM2000 This device complies with P art 15 of FCC Rules. Operation is subject to the f ollowing two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interf erence that may cause undesired operation T e c h n i c a l I I n f o r m a ...
-
Scytek electronic 5000RS PLUS SERIES - page 31
Galaxy 5000RS Plus - Page 27 N o t e s ...
-
Scytek electronic 5000RS PLUS SERIES - page 32
ScyTek Electronics 11627 Cantara Street Unit B North Hollywood, CA 91605 © ScyT ek Electronics 2003 Galaxy 5000RS r3 11/03 ...
Do you have a question concerning Scytek electronic 5000RS PLUS SERIES?
Use the form below
If you did not solve your problem by using a manual Scytek electronic 5000RS PLUS SERIES, ask a question using the form below. If a user had a similar problem with Scytek electronic 5000RS PLUS SERIES it is likely that he will want to share the way to solve it.