Manual Pentair JSAYDL

16 pages 0.28 mb
Download

Go to site of 16

Summary
  • Pentair JSAYDL - page 1

    DURA-JET TM PUMP O W N E R’ S M A N U A L INST ALLA TION, OPERA TION & P AR TS MODELS 1/2 HP 3/4 HP 3/4 HP 1 HP 1 HP 1-1/2 HP (2-Speed) (2-Speed) JSA CL JSADL JSA YDL JSAEL JSA YEL JSAFL JSADL-2A JSAEL-2A JSAEFL JSA YFL This manual should be given to the end user of this pump; its use will reduce service calls and chance of injury and will le ...

  • Pentair JSAYDL - page 2

    2 DURA-JET SP A PUMP To avoid unneeded service calls, prevent possible injuries, and get the most out of your pump, READ THIS MANUAL CAREFULLY! The Sta-Rite ‘JS’ Series Tub Pump: • Is designed to circulate hot water in spas and hot tubs. • Is an excellent performer; durable, reliable. T able of Contents Safety Instructions ................. ...

  • Pentair JSAYDL - page 3

    3 READ AND FOLLO W ALL INSTR UCTIONS! This is the safety alert symbol. When you see this symbol on your sys- tem or in this manual, look for one of the following signal words and be alert to the potential for personal injury. warns about hazards that will cause death, serious personal in- jury, or major property damage if ignored. warns about hazar ...

  • Pentair JSAYDL - page 4

    4 INST ALLA TION Installation and wiring of pump should only be done by qualified, licensed personnel. Pump mount must: Be Solid - Level - Rigid - Vibration free. (To reduce vibration and pipe stress, bolt pump to mount.) Be installed with pump suction inlet below water level at all times (this al- lows pump to prime). Be installed with pump discha ...

  • Pentair JSAYDL - page 5

    5 ELECTRICAL Ground motor before connecting to electrical power supply! Failure to ground pump motor can cause serious or fatal electrical shock hazard! Do not ground to a gas supply line! To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections. GFCI tripping indicates an electrical problem. If ...

  • Pentair JSAYDL - page 6

    6 V oltage: Voltage at motor must be not more than 10% above or below motor name- plate rated voltage or motor may overheat, causing overload tripping and re- duced component life. If voltage is less than 90% or more than 110% of rated voltage when motor is running at full load, consult power company. Values given in tables below are for PUMP MOTOR ...

  • Pentair JSAYDL - page 7

    7 OPERA TION Priming Pump: NEVER run pump dry! Running pump dry may damage seals, causing leakage and flooding! Fill pump with water before starting motor. Do not add chemicals to spa system directly in front of pump suction. Adding undiluted chemicals may damage pump and voids warranty. Open gate valves before starting system. Pump will prime itse ...

  • Pentair JSAYDL - page 8

    8 Pump should only be serviced by qualified personnel. To avoid dangerous or fatal electrical shock hazard, disconnect power to motor before working on pump or motor! No lubrication or regular maintenance are needed. If shaft seal is damaged, repair as follows: Removing Old Seal: 1. Disconnect power to pump motor. 2. Drain tub and pump; disconnect ...

  • Pentair JSAYDL - page 9

    9 5. Screw impeller onto shaft until it seats against shaft shoulder. Work slinger over end of impeller sleeve so it rides on sleeve (Figure 6). 6. Remount front plate; using pattern, shown in Figure 7, torque bolts to 30 inch-lbs. (34.5 cm-kg). BE SURE to start with bolt in 3 o’clock position as shown. 7. Reconnect unions; tighten hand tight onl ...

  • Pentair JSAYDL - page 10

    10 Draining Pump: To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor before draining pump. NOTICE: Do not use anti-freeze solutions (except propylene glycol) in your spa system. Most anti-freezes are hightly toxic and may damage plastic components in the system. Propylene glycol is non-toxic and will not damage pump compon ...

  • Pentair JSAYDL - page 11

    11 TR OUBLESHOO TING GUIDE Read and understand safety and operating instructions in this manual before doing any work on pump! A. PUMP DOES NO T OPERA TE 1. Check GFCI for proper operation according to GFCI manufacturer’s in- structions. 2. Check for plugged impeller. Follow disassembly/assembly instructions under “ Pump Service”, Page 8. 3. ...

  • Pentair JSAYDL - page 12

    12 1161 0695 1 5 8 9 7 3 4 6 2 11 11 12 1 2 13 7A • Not illustrated. * JSAFL-A, JSAEFL-A only. REP AIR P AR TS LIST DURA-JET TM SP A PUMP 3/4 through 1-1/2 HP Models Parts are common to all models listed except as noted; Key Nos. 1, Motor; and 8, Impeller, are listed below. Model Motor No. Impeller No. No. HP (Key No. 1) (Key No. 6) 115 Volt Sing ...

  • Pentair JSAYDL - page 13

    13 ...

  • Pentair JSAYDL - page 14

    14 ...

  • Pentair JSAYDL - page 15

    15 ...

  • Pentair JSAYDL - page 16

    S196 (Rev . A) 04-15-10 *S 196 * ...

Manufacturer Pentair Category Water Pump

Documents that we receive from a manufacturer of a Pentair JSAYDL can be divided into several groups. They are, among others:
- Pentair technical drawings
- JSAYDL manuals
- Pentair product data sheets
- information booklets
- or energy labels Pentair JSAYDL
All of them are important, but the most important information from the point of view of use of the device are in the user manual Pentair JSAYDL.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Pentair JSAYDL, service manual, brief instructions and user manuals Pentair JSAYDL. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Pentair JSAYDL.

Similar manuals

A complete manual for the device Pentair JSAYDL, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Pentair JSAYDL by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Pentair JSAYDL.

A complete Pentair manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Pentair JSAYDL - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Pentair JSAYDL, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Pentair JSAYDL, that we can find in the current document
3. Tips how to use the basic functions of the device Pentair JSAYDL - which should help us in our first steps of using Pentair JSAYDL
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Pentair JSAYDL
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Pentair JSAYDL in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Pentair JSAYDL?

Use the form below

If you did not solve your problem by using a manual Pentair JSAYDL, ask a question using the form below. If a user had a similar problem with Pentair JSAYDL it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)