Manual Keating Of Chicago 240V

23 pages 1.57 mb
Download

Go to site of 23

Summary
  • Keating Of Chicago 240V - page 1

    KEEP THIS MANU AL FOR TRAINING NEW PERSONNEL 1-800-KEA TING www .keatingofchicago.com Part # 000000 Electric Pasta 0107 09/07 CUST OM P AST A ™ SYSTEM ELECTRIC SER VICE MANU AL ...

  • Keating Of Chicago 240V - page 2

    i This operating, installation, and service manual should be given to the user . T he operator of the Custom Past a ™ System should be familiar with the functions and operation of the cooker . T his manual must be kept in a prominent, easily reachable location near the Pasta System. P OST T H I S L AB E L I N A P R O M I N E NT LO CA T I O N O N ...

  • Keating Of Chicago 240V - page 3

    SECTION I SPECIFICA TIONS . . . . . . . . . . . . . . 1 SECTION II INST ALLA TION Shipment and T ransit . . . . . . . . . . . . . . . . . . . . . . . .1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 A. Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 B. Electrical Connection . . . . . . . . . . . ...

  • Keating Of Chicago 240V - page 4

    2 I INTRODUCTION GENERAL Keating Electric Custom Pasta ™ Systems are designed to give maximum production efficiency , delivering high quality food products. The following design features are incorporated in Keating Pasta Electric Systems. ST ANDARD FEA TURES • Highly polished stainless steel vessel • Highly polished stainless steel front • ...

  • Keating Of Chicago 240V - page 5

    • Keating Custom Pasta ™ Systems are intended for other than household use. • AL WA YS instruct new employees on proper pasta system operation. • A Custom Pasta System ™ should be operated ONL Y by properly trained personnel. • AL WA YS turn pasta system off each night. • AL WA YS turn pasta system off at customer power panel before s ...

  • Keating Of Chicago 240V - page 6

    4 POSITIONING The past a cooker must be no closer than 6" from any combustible material. When placed under an exhaust hood with a fire retardant system it must comply with ANSI/UL 507-(Latest Edition) and ANSI/NFP A 96- (Latest Edition). No frame or restriction can be constructed around the lower part of the p asta cooker that would restrict v ...

  • Keating Of Chicago 240V - page 7

    5 In most cases the health department will not allow a direct connection between the cooker drain and the floor receptical. Contact your local health dep artment for specific information in your area. III OPERA TION FILLING   NOTE: Before filling the Past a System make certain the vessel is sanitized, dry and the drain valve is completely clo ...

  • Keating Of Chicago 240V - page 8

    6 procedures below for your model.   NOTE : Use of sodium chloride during the cooking process will have a detrimental ef fect on the cooker tank and will void the warranty .   OPERA TION OF THIS P AST A SYSTEM SHOULD BE LIMITED TO PERSONNEL WHO HA VE BEEN THOROUGHL Y TRAINED IN OPERA TING PROCEDURES.   USE ONL Y KEA TING APPROVED ...

  • Keating Of Chicago 240V - page 9

    7 3. Drain water from Pasta System. 4. Fill Pasta System vessel with water . See page 7 – Filling. UNDER NO CIRCUMST ANCES SHOULD THE P AST A SYSTEM BE LEFT UNA TTENDED DURING BOIL-OUT . TRAINED PERSONNEL MUST BE PRESENT DURING THE PROCEDURE TO PREVENT BOIL OVER OR T O TURN OFF THE POWER IF W A TER DROPS BELOW HEA T TRANSFER TUBES. 5. T urn Pasta ...

  • Keating Of Chicago 240V - page 10

    8 contact s will open, the display will flash, and the audible alarm will sound. T o cancel the audible alarm, press any button. C. P AUSE FEA TURE T o pause a cycle in progress, press any button. The relay output contact s will open, the display will flash, and the countdown will p ause. T o resume the countdown, press any button. The display will ...

  • Keating Of Chicago 240V - page 11

    9 B. The W ater Auto-Fill and Low Water Safety Shut- Off Systems The water supply connection, located at the bottom rear of the Pasta System and marked water , is a standard 3 / 8 ” female pipe connection. The water pressure should be between 20-60 psi. If the pressure exceeds 60 p si, a pressure regulator must be used. The water temperature must ...

  • Keating Of Chicago 240V - page 12

    10 V SER VICE AND P ARTS INFORMA TION THE COOKER MUST BE DISCONNECTED FROM ITS POWER SOURCE OR SHUT DOWN A T THE BREAKER PRIOR TO SER VICE. AUTO-FILL SYSTEM The auto-fill system allows the automatic addition of water to the past a cooker during cooking or idle function. The system is controlled by the on/of f switch explained in CLEANING . If the s ...

  • Keating Of Chicago 240V - page 13

    11 COMMON PROBLEMS SOLUTIONS (FOLLOW IN SEQUENCE) W ater always filling 1. Clean sensors thoroughly with brush and vinegar . 2. Adjust the sensitivity of the B Board (for the top sensor) fully clockwise. 3. If filling persists, ground out the top sensor (if filling stops, replace sensor – Part #010212). 4. If filling persists after grounding the ...

  • Keating Of Chicago 240V - page 14

    PROBLEM PROBABLE CAUSE SOLUTION Pasta Cooker has poor recovery or runs cold. a. Over-filling basket s. b.Thermostat out of calibration. c. Element is faulty . d. Thermost at is faulty . e. Cont actor is faulty . a. Don’t overfill basket s. b. Calibrate thermost at. See page 4 - Calibration. c. Replace element. d. Replace thermost at. e. Replace c ...

  • Keating Of Chicago 240V - page 15

    VII P ARTS LIST CUSTOM P AST A SYSTEM ELECTRIC CONTROL P ANEL ASSEMBL Y 13 ITEM # DESCRIPTION QTY P ART # 1 INDICA TING LIGHT , AMBER, POWER ON 1 031624 2 TOGGLE SWITCH– MAIN ON-OFF 2 004499 3 INDICA TING LIGHT , GREEN, THERMOST A T HEA TING 2 010682 4 INDICA TING LIGHT , WA TER FILLING 1 009256 5 MANUAL W A TER FILL BUTT ON 1 004304 NUT WITH BOO ...

  • Keating Of Chicago 240V - page 16

    14 P ARTS LIST FOR CUSTOM P AST A SYSTEM ™ ITEM DESCRIPTION MODELS P ART # 14 18 20 24 1 HEA TING ELEMENT 220V 6500W 14" ONL Y 018668 3 1 HEA TING ELEMENT 18" & 20" ONL Y 004353 2 2 2 DRAIN V AL VE – 1" FRONT 14" ONL Y 026813 1 2 DRAIN V AL VE HANDLE – 1" FRONT 14" ONL Y 016387 1 2 DRAIN V AL VE – 1 1 ...

  • Keating Of Chicago 240V - page 17

    15 P ARTS LIST FOR 14" DROP-IN CUSTOM P AST A SYSTEM DESCRIPTION QTY P ART# THERMOST A T DIAL PLA TE 2 034975 AMBER INDICA TING LIGHT 1 031624 GREEN INDICA TING LIGHT 2 010682 BLUE INDICA TING LIGHT 1 009256 PUSH BUTTON MOMENT ARY SWITCH 1 004304 TOGGLE SWITCH – ON-OFF 2 004499 THERMOST A T KNOB 2 004163 THERMOST A T 2 031466 HEA TING ELEMEN ...

  • Keating Of Chicago 240V - page 18

    16 VIII WIRING DIAGRAMS 14" ELECTRIC P AST A 2-THERMOST A T WIRING DIAGRAM (WITHOUT TIMERS) ...

  • Keating Of Chicago 240V - page 19

    17 14" ELECTRIC P AST A WITH 138 TIMERS WIRING DIAGRAM ...

  • Keating Of Chicago 240V - page 20

    18 18" & 20" ELECTRIC P AST A WITH 138 TIMERS WIRING DIAGRAM ...

  • Keating Of Chicago 240V - page 21

    19 18" ELECTRIC P AST A 2-THERMOST A T WIRING DIAGRAM (WITHOUT TIMERS) ...

  • Keating Of Chicago 240V - page 22

    L IMITED W ARRANTY Keating Of Chicago, Inc. ("Keating”) warrants to the original purchaser . ("Customer"), all new Keating Fryers, Filter Systems, Griddles, Keep Krisp ® , Custom Pasta Systems, T op-Side™ Cookers, Computer T imers, Fryer & Pasta V essels, and Keating replacement parts ("products") installed after J ...

  • Keating Of Chicago 240V - page 23

    KEA TI NG LI M ITE D W AR RANTY C AR D PLEASE C OM P LETE AN D MAI L A T O NC E–W AR RANTY IS N O T I N E F FE CT UNTI L CAR D IS R ETU R N E D W AR RANTY R EG I STRA TIO N IS ALSO AV AI LAB LE ON LI N E FO R Y OU R C ONVE N I E N CE CO M P ANY: ______________________________________________________________________________________________________ ...

Manufacturer Keating Of Chicago Category Pasta Maker

Documents that we receive from a manufacturer of a Keating Of Chicago 240V can be divided into several groups. They are, among others:
- Keating Of Chicago technical drawings
- 240V manuals
- Keating Of Chicago product data sheets
- information booklets
- or energy labels Keating Of Chicago 240V
All of them are important, but the most important information from the point of view of use of the device are in the user manual Keating Of Chicago 240V.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Keating Of Chicago 240V, service manual, brief instructions and user manuals Keating Of Chicago 240V. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Keating Of Chicago 240V.

A complete manual for the device Keating Of Chicago 240V, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Keating Of Chicago 240V by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Keating Of Chicago 240V.

A complete Keating Of Chicago manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Keating Of Chicago 240V - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Keating Of Chicago 240V, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Keating Of Chicago 240V, that we can find in the current document
3. Tips how to use the basic functions of the device Keating Of Chicago 240V - which should help us in our first steps of using Keating Of Chicago 240V
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Keating Of Chicago 240V
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Keating Of Chicago 240V in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Keating Of Chicago 240V?

Use the form below

If you did not solve your problem by using a manual Keating Of Chicago 240V, ask a question using the form below. If a user had a similar problem with Keating Of Chicago 240V it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)