Manual Liebert GXT3-10000T220

32 pages 2.05 mb
Download

Go to site of 32

Summary
  • Liebert GXT3-10000T220 - page 1

    AC P ow er For Bu siness-Criti cal C ontinuity™ Li eb er t ® GX T3-10000T220 ™ User Ma nual, 10 kVA, 50/60 Hz, 120/208/220V ...

  • Liebert GXT3-10000T220 - page 2

    ...

  • Liebert GXT3-10000T220 - page 3

    i T ABLE OF CONTENTS I MPORT AN T S AFE TY I NSTRUC TIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.0 I NTRODUCTI ON AND S YSTEM D ESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.1 Device Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Liebert GXT3-10000T220 - page 4

    ii 5.0 M AINTENAN CE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 5.1 Test, Replacement and Disposal of Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 5.2 Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Liebert GXT3-10000T220 - page 5

    1 I MPORT ANT S AFETY I NSTRUCTIONS SAVE THESE INSTRUCTIONS This manual con tains important safety i nstructions. Read al l safety and opera ting instructions before operating the uninterrupti ble power system (UPS). Adhere to all warnin gs on the unit and in this manual. Follow all operating a nd user instructio ns. This equipment must be operated ...

  • Liebert GXT3-10000T220 - page 6

    2 ! WARNING Although the Liebert ® GXT3 ™ has been designed and manufactured to ensure safety, improper use can result in electrical shock or fire. To ensure safety, observe the following precautions: • Turn Off and isolate the Liebert G XT3 before cl eaning it. Use only a soft cloth; never use liquid or aerosol cleaners. • Never block or in ...

  • Liebert GXT3-10000T220 - page 7

    3 Leakage Current ELECTROMAGNETIC COM PATIBILITY —The Liebert ® GXT3 ™ complies with the limits for a Class A Digital Device, Pursuant to Part 15 of FCC ru les. Operation is su bject to the follow ing conditions: • This device may not ca use harmful interference • This device must accept any interference received, includin g interference t ...

  • Liebert GXT3-10000T220 - page 8

    Introduction and System Descriptio n 4 1.0 I NTRODUCTION AND S YSTEM D ESCRIPTION Congratulations on your choice of the Liebert ® GXT3 ™ -10000T220 UPS. It provid es conditioned power to microcomputers and other se nsitive electronic equipment. When generated, AC power is clean and stable . Howe ver, during transmission and distribution it is su ...

  • Liebert GXT3-10000T220 - page 9

    Introduction and System Descriptio n 5 1.1 Device Overview The following table provides an overview of the various versions of the device: Figure 2 Liebert ® GXT3-10000T220 ™ front and rear vie ws T able 1 Overview of UPS devices and bat teries Type Model # Nominal power UPS with Integr ated Battery Liebert ® GXT3-10000T220 ™ 10000VA/90000W B ...

  • Liebert GXT3-10000T220 - page 10

    Unpacking the UPS an d Site Preparation 6 2.0 U NP ACKING THE UPS AND S ITE P REP ARATION 2.1 Inspection Upon receiving your Liebert ® GXT3-10000T2 20 ™ , examine the packaging for any signs of mishandling or damage. While remo ving shipping materi als, inspect the UPS for damage. If any damage is noted, notify your local Li ebert representative ...

  • Liebert GXT3-10000T220 - page 11

    Unpacking the UPS an d Site Preparation 7 2.4 Environment al Conditions Install the Liebert ® GXT3 ™ indoors in a controlled environmen t where it cannot be accidentally turned off. Pla ce it on a level, even surface in an area with unrestricted ai rflow around the uni t. The installation location must be fr ee of water, flammable liquids, gase ...

  • Liebert GXT3-10000T220 - page 12

    Installation 8 3.0 I NST ALLATION 3.1 Electrical prep arations Before beginning installation , the input source must be isolated an d locked out to prevent connection during installation. The input circu it breaker on the rear of the UP S m ust be in the Off position. 3.2 Suggested Cable Sizes 3.3 External Protection and Isolating Devices An extern ...

  • Liebert GXT3-10000T220 - page 13

    Installation 9 3.4 External Elect rical Connections The external electrical connections may be accessed by re moving the protective panel on the rear of the UPS (see Figure 2 ) (panel ships loose from fa ctory). Se lect a conduit knockout appropriate for your cabling, based on local electrical codes. Figure 4 Side view 3.5 Connecting Utility and Lo ...

  • Liebert GXT3-10000T220 - page 14

    Installation 10 Figure 6 Dual source input su pply—input and output connections Figure 7 Hardwire terminals 3.6.1 Input and Output Connection Requirement s • Any 120V loads mus t be distributed evenly be tween X1-X2, X1 -X4 and X4-X2. Do not conn ect loads between X3-X2 or between X3-X4—these are not standard voltages. • The single-phase is ...

  • Liebert GXT3-10000T220 - page 15

    Installation 11 3.7 Connecting Power Cables 1. Open the UPS input breaker. 2. Op en the UPS bypass breaker. 3. Set the maintenance breake r to the Bypass position. 4. Remo ve the electrical connection protective panel, if insta lled, from the rear UPS panel. 5. Connect loads to the output terminals as illustrated in Figure 7 . 6. Connect the utilit ...

  • Liebert GXT3-10000T220 - page 16

    Operation 12 4.0 O PERATION 4.1 Block Diagram The Liebert ® GXT3-10000T220 ™ consists of the following main components: • 2 utility inputs wi th separa te breakers—uti lity and bypass • rectifier/booster, inverter and charger • electronic bypass • 2-position Maintenance Bypass Breaker—UPS and BYPASS • integrated battery Figure 9 Sy ...

  • Liebert GXT3-10000T220 - page 17

    Operation 13 4.2 Control Panel The Control Panel’s LCD and buttons are used to initiate various UPS operations, tests and commands and to view the status of the UPS. By pressing the Menu Up or Menu Down and Ente r keys , it is possible to scroll through the various menus. For details, see 4.2.1 - Controls and Messages and Figure 11 . Figure 10 Co ...

  • Liebert GXT3-10000T220 - page 18

    Operation 14 Figure 1 1 Menu tree St a rt W indow Syst em St at us Ma i n Setup Cont rol Cont ras t Set Batt e ry Te s t Al arm Cont rol Tu r n U PS On /Off St at us Log About Versi o n Language T ag Num ber UPS Addr ess DC S t art Batt e ry Te s t In t e r v a l Batt e ry Pack Audible Al arm O ut put Volt age Clear Ev ent Log IP T ypes Batt e ry T ...

  • Liebert GXT3-10000T220 - page 19

    Operation 15 T able 3 Displayed text—syst em block and main menu Item # and Name Description Status Menu Measure value Unit Output Volt V Output Freq 0.1Hz Output Current A Output Watt W Output VA VA Output Load % Input Volt V L2 Input Volt N/A L3 Input Volt N/A Input Freq 0.1Hz Back Voltage V Batt Capacity % Backup Time min:sec Run Time day:hr:m ...

  • Liebert GXT3-10000T220 - page 20

    Operation 16 4.2.2 Battery Setup Parameters 4.2.3 W arning Indicators If a warning indicat ion appears, the UPS continues to operate. The warning message altern ates with UPS mode once a second. The various possible warnin g indicators are listed in the following table: Control Menu Turn UPS ON/OFF Turn UPS to ONLINE Turn UPS to BYPASS Turn UPS to ...

  • Liebert GXT3-10000T220 - page 21

    Operation 17 4.2.4 Fault Indicators If a fault occurs, the UPS automatically switches to BYPASS mode, ONLY in case of a battery disconnect fault will the original operating mode be maintained. Th e fault message alternates with UPS mode once a second, the red Fault LED illuminates on the control panel and the buzzer sounds continuously. If a fault ...

  • Liebert GXT3-10000T220 - page 22

    Operation 18 4.3 Initial UPS St artup Procedure 1. Inspect all power connections to en sure they are correct and secure. 2. Open external circuit breakers/fused di sconnect s to the connected loads. 3. Cl ose all upstream circuit breakers an d fused disconnects. 4. Use a voltmeter to verify proper input voltage is present on the UPS and Byp ass inp ...

  • Liebert GXT3-10000T220 - page 23

    Operation 19 4.6 Return from Maintenance Byp ass 1. Ensure all switches and circuit brea kers upstream of the UPS are closed. 2. En sure that both input circuit breake rs are in th e On position. 3. Turn the Maintenance breake r from BYPASS to UPS and replace the cover. The load now is suppl ied via electronic by pass. 4. Press the Menu button , se ...

  • Liebert GXT3-10000T220 - page 24

    Maintenance 20 5.0 M AINTENANCE 5.1 T est, Replacement and Disposal of Batteries The Liebert ® GXT3 ™ is designed to allow the us er to replace the internal ba ttery pack safely. Refer to Table 7 for internal battery pack part numbers for Li ebert GXT3 UPS and Liebert Ext ernal Battery Cabinets: Read all safety cautions before proceeding. Contac ...

  • Liebert GXT3-10000T220 - page 25

    Communication 21 6.0 C OMMUNICATION 6.1 Communication Interface Port The Liebert ® GXT3 ™ UPS has a terminal block on the rear of the UPS unit. Several signals are provided on this port and are assigned as follows. 6.2 Dry Cont act The Dry Contact includes eight pins, as shown an d defined in Figure 12 . Figure 12 Dry cont act pin layout 6.2.1 A ...

  • Liebert GXT3-10000T220 - page 26

    Communication 22 6.2.2 Battery Mode Shut down Battery Mode Shutdown permits shutting down the UPS by turning off the rectifier, inverter and static switch so that there is no powe r to the lo ad when the UPS is On Ba ttery. The auxiliary power for the UPS will st ill be active. Battery Mode Shutdown can be performed locally or remotely: • Local B ...

  • Liebert GXT3-10000T220 - page 27

    Communication 23 6.3.1 Liebert ® MultiLink ® Liebert MultiLink continua lly monitors the UPS and can shut down your computer or server in the event of an extended power failure. Liebert MultiLi nk can also be configured for use without the USB cable when the Liebert IntelliSlot ® SNMP/Web card is installed in the UPS. Additionally, Liebert Multi ...

  • Liebert GXT3-10000T220 - page 28

    Trou bleshooting 24 7.0 T ROUBLESHOOTING If any technical problems should occur, ch eck the f ollowing before contacting Liebert ® technical support: • Is the utility vo ltage pr esent at the UPS input? • Has the input fuse bl own or ha ve the circuit breakers tripped? • Has the UPS startup procedure been followed corre ctly? When contacting ...

  • Liebert GXT3-10000T220 - page 29

    Specifications 25 8.0 S PECIFICATIONS Ta b l e 9 L i e b e r t ® GXT3 ™ specifications Model Rating, VA (W) 10,000 (9000) Dimensions, in. (mm) Unit, W x D x H 31.5 x 11.81 x 26.57 (800 x 300 x 675) Shipping, W x D x H 41.8 x 16.7 x 34 (1062 x 426 x 866) Weight, lb (kg) Unit 308 (140) Shipping 428 (194) Input AC Parameters Nominal Operating Frequ ...

  • Liebert GXT3-10000T220 - page 30

    Specifications 26 T able 10 Battery cabinet specificat ions Model Number GXT3-240TBATTCE Dimensions, W x D x H, in. (mm) Unit 31.5 x 11.81 x 26.57 (800 x 300 x 675) Shipping 41.8 x 16.7 x 34 (1062 x 426 x 866) Weight, lb (kg) Unit 243 (110) Shipping 309 (140) Internal Battery Parameters Type Valve-regulated, non-spillable, lead acid Quantity x V 2 ...

  • Liebert GXT3-10000T220 - page 31

    Product Warranty Registra tion 27 9.0 P RODUCT W ARRANTY R EGISTRATION To register for warranty protection: • Visit the Quick Links section of Liebert’s Web site at: http://www.liebert.com • Click on Product Warranty Registration and fill in the form. If you have any questions, please contact us at: • US: 800-222-5877 • Outside the US: 61 ...

  • Liebert GXT3-10000T220 - page 32

    Ensuring The Hi gh Av aila bilit y Of Mission-Critic al Data And Ap plic ations. Emerson Net work P ower , a business of Emerson (NYSE:EMR), is the global leader in enabling Business-Critic al Continuity ™ from grid to chip f or telecommunication networks, data centers, health care and industrial facilities. Emerson Network Po wer provides inno v ...

Manufacturer Liebert Category Power Supply

Documents that we receive from a manufacturer of a Liebert GXT3-10000T220 can be divided into several groups. They are, among others:
- Liebert technical drawings
- GXT3-10000T220 manuals
- Liebert product data sheets
- information booklets
- or energy labels Liebert GXT3-10000T220
All of them are important, but the most important information from the point of view of use of the device are in the user manual Liebert GXT3-10000T220.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Liebert GXT3-10000T220, service manual, brief instructions and user manuals Liebert GXT3-10000T220. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Liebert GXT3-10000T220.

A complete manual for the device Liebert GXT3-10000T220, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Liebert GXT3-10000T220 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Liebert GXT3-10000T220.

A complete Liebert manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Liebert GXT3-10000T220 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Liebert GXT3-10000T220, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Liebert GXT3-10000T220, that we can find in the current document
3. Tips how to use the basic functions of the device Liebert GXT3-10000T220 - which should help us in our first steps of using Liebert GXT3-10000T220
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Liebert GXT3-10000T220
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Liebert GXT3-10000T220 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Liebert GXT3-10000T220?

Use the form below

If you did not solve your problem by using a manual Liebert GXT3-10000T220, ask a question using the form below. If a user had a similar problem with Liebert GXT3-10000T220 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)