Manual Paradyne Hotwire 5446

23 pages 0.27 mb
Download

Go to site of 23

Summary
  • Paradyne Hotwire 5446 - page 1

    TM 1 Hotwire  5446 RTU Customer Premises Installation Instructions Document Number 5446-A2-GN10-60 May 1999 Before Y ou Begin The Hotwire  5446 RTU (Remote T ermination Unit) interoperates with the Hotwire 8546 DSL Card in the DSLAM (Digital Subscriber Line Access Multiplexer) system. An optional POTS (Plain Old T elephone Service) splitter i ...

  • Paradyne Hotwire 5446 - page 2

    2 Package Checklist V erify that your package contains the following: - Model 5446 Remote T ermination Unit (RTU) - DSL interface cable with RJ1 1 connectors - Power cord with power transformer Refer to Cables & Connectors, page 17, for standard pin numbers. Be sure to register your warranty at www .paradyne.com . Select Service & Support ? ...

  • Paradyne Hotwire 5446 - page 3

    3 98-16105 Punchdown Block or NID DSL Jack RTU Customer Premises (CP) DSL Ethernet Crossover Cable Ethernet Cable or Central Office (CO) Demarcation Point Local Loop CP POTS Splitter DSL – Digital Subscriber Line POTS – Plain Old T elephone Service NID – Network Interface Device R TU – Remote T ermination Unit POTS End-user Systems Network ...

  • Paradyne Hotwire 5446 - page 4

    4 DSL Access without a POTS Splitter When the Hotwire 5446 RTU is installed without a POTS splitter , a second telephone wiring pair is needed for DSL access. 98-16104 Punchdown Block or NID DSL Jack RTU Customer Premises (CP) POTS DSL Ethernet Crossover Cable Ethernet Cable or Central Office (CO) Demarcation Point Local Loop Hub or Router End-user ...

  • Paradyne Hotwire 5446 - page 5

    5 Installing the DSL Access Wiring The local loop terminates at the punchdown block or NID. Wiring must be connected from the customer premises side of the punchdown block or the NID to an RJ1 1 jack. T ypically , the punchdown block is installed in commercial locations and the NID is installed in residential locations.  Procedur e 1. Access the ...

  • Paradyne Hotwire 5446 - page 6

    6 3. Locate the DSL pair of T1/R1 connectors on the customer premises side of the NID or punchdown block. Attach the wiring that will be connected to the DSL jack. In the following example, a NID is used without a POTS splitter . It includes an existing POTS line and a second pair installed for DSL access. DSL/PO TS Access from Local Loop Wiring to ...

  • Paradyne Hotwire 5446 - page 7

    97-15300a RJ11 W all Jack or 7 The 5446 RTU connects to the local loop via wiring from the demarcation point to an RJ1 1 wall jack. The DSL twisted-pair wiring from the local loop terminates at a new or existing wall jack. It may be necessary to install a standard single RJ1 1 jack or replace a single jack with a double RJ1 1 jack. 97-15343-02 DSL ...

  • Paradyne Hotwire 5446 - page 8

    8 Installing the Hotwire 5446 R TU Place the Hotwire 5446 RTU on a flat surface with clearance for the rear connectors.  Procedur e 1. Use the supplied RJ1 1 6-pin interface cable for the DSL connection. Insert one end of the cable into the jack labeled DSL. Insert the other end into the wall jack labeled DSL. 97-15300-01 DSL Jack POWER ETHERNET ...

  • Paradyne Hotwire 5446 - page 9

    9 2. Use an 8-pin Ethernet cable for the Ethernet connection. Insert one end of the cable into the jack labeled ETHERNET .  Use a straight-through cable and connect the other end to an Ethernet hub, or 97-15303-01 Ethernet Hub Ethernet Line PO WER ETHERNET DSL Hotwire RTU Ethernet Cable  Use an Ethernet crossover cable and connect the other e ...

  • Paradyne Hotwire 5446 - page 10

    10 3. Insert the power cord’s round end into the jack labeled POWER. Plug the transformer into an AC outlet. 98-15836 PO WER ETHERNET DSL Hotwire RTU Po w e r Jack or T ransformer or The RTU hardware installation is now complete. When the power cord is installed, the RTU goes through a power-on self-test. Power -On When power is applied, the RTU ...

  • Paradyne Hotwire 5446 - page 11

    11 Optional R TU W all Placement The Hotwire 5446 RTU is designed for tabletop placement. The R TU can also be mounted on a wall. T o mount an RTU, you will need: - Three slotted-head #6 self-threading screws with molly bolts - Drill and 3/16” drill bit for the molly bolts - Screwdriver A template with the dimensions for the three screws is provi ...

  • Paradyne Hotwire 5446 - page 12

    12 R TU Hardwar e T emplate F ront (LEDs) 98-16171 5.43" 7.55" T o Bottom Hole ...

  • Paradyne Hotwire 5446 - page 13

    13 Status LEDs All of the LEDs turn on and off during the power-on self-test. After a successful self-test, the LEDs should appear as indicated in BOLD in the Condition column below . LED Condition Status PWR ON RTU has power . ALM OFF ON No active alarms. An alarm condition exists. TST OFF ON No active tests. The TST LED is on during the power-on ...

  • Paradyne Hotwire 5446 - page 14

    14 T roubleshooting LED Symptom Action All LEDs are on. If the LEDs remain on after ten minutes, the RTU is not functional. Contact the NSP . ALM LED remains on. The power-on self-test may have failed. Unplug the unit and reapply power . If the alarm light is still on, contact the NSP . ALM and TST LEDs are blinking. Firmware download may be in pro ...

  • Paradyne Hotwire 5446 - page 15

    15 Hotwire 5446 R TU Next Hop Router Support The Hotwire 5446 RTU now includes support for next hop routers and a default gateway . The following illustration includes a router and a default gateway . The maximum of 32 end-user systems applies to end-user systems directly connected to the 5446 RTU (with or without a hub) and end-user systems connec ...

  • Paradyne Hotwire 5446 - page 16

    16 Hotwire 5446 R TU IP Setup The Hotwire 5446 RTU hardware installation is now complete. Additional steps are required by the NSP to utilize the DSL and Ethernet connections. Network Service Provider Example The ISP:  Assigns and sets up the RTU IP address and subnet mask.  Assigns the IP address and subnet mask for each end-user system conn ...

  • Paradyne Hotwire 5446 - page 17

    98-15304-01 6-Pin RJ11 Plug DSL Cable Pin #1 Pin #6 17 Increasing the Number of End-User Systems A single end-user system is attached to the Hotwire 5446 RTU by using an Ethernet crossover cable. T o increase the number of end-user systems, connect all end-user systems to an Ethernet hub using straight-through Ethernet cable. Refer to Installing th ...

  • Paradyne Hotwire 5446 - page 18

    98-16055a 8-Pin Plug Ethernet Cable Pin #1 Pin #8 18  The Ethernet interface connector uses an 8-pin, non-keyed modular plug. — T o connect to an Ethernet hub, use the straight-through connection. 8-Pin Straight-Through Connection Pin # Function 1 10BaseT TX D+ 2 10BaseT TX D– 3 10BaseT RX D+ 4 & 5 Not used 6 10BaseT RX D– 7 & 8 No ...

  • Paradyne Hotwire 5446 - page 19

    19 Hotwire 5446 R TU T echnical Specifications Item Specification * Height x Width x Depth 1.43 ″ x 6.00 ″ x 8.75 ″ (3.64 cm x 15.24 cm x 22.23 cm) Weight 1 lb. 1 oz. (0.48 kg) Power Class 2 T ransformer normal service input voltage range Input: 100 V ac (+ 10%), 50 Hz; 120 V ac (+ 10%), 60 Hz; or 230 V ac (+ 10%), 50/60 Hz Output: 18 Vdc nom ...

  • Paradyne Hotwire 5446 - page 20

    20 ! Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. Slots and openings in the cabinet are provided for ventilation. T o ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered. 3. Do ...

  • Paradyne Hotwire 5446 - page 21

    21 Declaration of Conformity This Declaration of Conformity is made by Paradyne Corporation pursuant to Parts 2 and 15 of the Federal Communications Commission’s Rules. This compliance information statement pertains to the following products: T rade Name: Hotwire Model Number: 5446-A3-200 This device complies with Part 15 of the FCC Rules. Operat ...

  • Paradyne Hotwire 5446 - page 22

    22 CE Marking When the product is marked with the CE mark, this demonstrates full compliance with the following European Directives:  Directive 73/23/EEC – Council Directive of 19 February 1973 on the harmonization of the laws of the member states relating to electrical equipment designed for use within states relating to electrical equipment ...

  • Paradyne Hotwire 5446 - page 23

    23 The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the device ...

Manufacturer Paradyne Category Modem

Documents that we receive from a manufacturer of a Paradyne Hotwire 5446 can be divided into several groups. They are, among others:
- Paradyne technical drawings
- Hotwire 5446 manuals
- Paradyne product data sheets
- information booklets
- or energy labels Paradyne Hotwire 5446
All of them are important, but the most important information from the point of view of use of the device are in the user manual Paradyne Hotwire 5446.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Paradyne Hotwire 5446, service manual, brief instructions and user manuals Paradyne Hotwire 5446. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Paradyne Hotwire 5446.

Similar manuals

A complete manual for the device Paradyne Hotwire 5446, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Paradyne Hotwire 5446 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Paradyne Hotwire 5446.

A complete Paradyne manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Paradyne Hotwire 5446 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Paradyne Hotwire 5446, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Paradyne Hotwire 5446, that we can find in the current document
3. Tips how to use the basic functions of the device Paradyne Hotwire 5446 - which should help us in our first steps of using Paradyne Hotwire 5446
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Paradyne Hotwire 5446
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Paradyne Hotwire 5446 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Paradyne Hotwire 5446?

Use the form below

If you did not solve your problem by using a manual Paradyne Hotwire 5446, ask a question using the form below. If a user had a similar problem with Paradyne Hotwire 5446 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)