  • DMP Electronics Command Processor Panel - page 1

    LT-0230 (2/97) Do Not Throw Away! This programming guide contains information you need to program and service the XR10 panel and should be kept along with your other DMP technical documentation. XR10 Command Processor Panel Programming Guide 10 Zone Burglary/Fire/Access Control Panel with Built-in Communicator 2841 E. Industrial Drive Springfield, ...

  • DMP Electronics Command Processor Panel - page 2

    MODEL XR10 PROGRAMMING GUIDE Copyright © 1995 - 1997 Digital Monitoring Products, Inc. Information furnished by DMP is believed to be accurate and reliable. This information is subject to change without notice. When using the Series XR10 control for any UL, NFPA, CSFM or other listing organization's approved methods, refer to this manual and ...

  • DMP Electronics Command Processor Panel - page 3

    TABLE OF CONTENTS Introduction .................................................................................................................................................................. 1 1.1 Before Y ou Begin .................................................................................................................................... ...

  • DMP Electronics Command Processor Panel - page 4

    TABLE OF CONTENTS Section Page 6.1 SYSTEM OPTIONS ................................................................................................................................................ 9 6.2 ALL/PERIMETER ....................................................................................................................................... ...

  • DMP Electronics Command Processor Panel - page 5

    1 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 1-INTRODUCTION Introduction 1.1 Before You Begin About this Guide This guide provides programming information for the DMP XR10 Command Processor Panel. After this Introduction, the remaining sections describe the functions of each programming menu item along w ...

  • DMP Electronics Command Processor Panel - page 6

    2 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 1 - INTRODUCTION 1.4 Programmer Lockout Codes Although the XR10 panel allows you to enter the built-in Programmer without a lockout code, we recommend you install one to restrict programming access to only those persons your company authorizes. You can do this ...

  • DMP Electronics Command Processor Panel - page 7

    3 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 1 - INTRODUCTION If you are changing a phone number or account number, press the SELECT key followed by the appropriate digit keys. If entering a communication type or choosing a programming option, the keypad displays the available response options above the ...

  • DMP Electronics Command Processor Panel - page 8

    4 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 2 - INITIALIZATION 2.1 INITIALIZATION This function allows you to set the panel's user codes and Programmer selections back to factory defaults before programming the panel for the first time or a new installation. After you select YES to clear a section ...

  • DMP Electronics Command Processor Panel - page 9

    5 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 3 - COMMUNICATION 3.6 TEST FREQUENCY Allows you to set how often the panel's test report is sent to the receiver. Enter from 1 to 60 days. Enter zero to disable the test report. How to set the Recall Test time Once you have finished programming the panel, ...

  • DMP Electronics Command Processor Panel - page 10

    6 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 3.16 PAGER REPORTING YES allows the panel to send Alarm, Trouble, Opening, and Closing reports to a numeric pager. The panel uses DTMF tones to generate the account and report information sent over the pager terminal equipment. Selecting NO allows you to use t ...

  • DMP Electronics Command Processor Panel - page 11

    7 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 4 - REMOTE OPTIONS 4.1 REMOTE OPTIONS This section allows you to enter the information needed for Remote Command/Remote Programming operation. A description of the Remote Options follow: 4.2 REMOTE KEY This option allows you to enter a code of up to eight digi ...

  • DMP Electronics Command Processor Panel - page 12

    8 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 5.1 SYSTEM REPORTS This section of the Programmer allows you to select the reports the XR10 sends to the receiver. 5.2 OPENING/CLOSING REPORTS YES allows the panel to send opening/closing reports by user to the receiver. 5.3 ABORT REPORT YES allows the panel t ...

  • DMP Electronics Command Processor Panel - page 13

    9 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 6.1 SYSTEM OPTIONS This section allows you to select system wide functions of the XR10 system. 6.2 ALL/PERIMETER YES configures the panel as a Perimeter (Area 1) and Interior (Area 2) system. NO configures the panel for Home/Sleep/Away operation. In addition t ...

  • DMP Electronics Command Processor Panel - page 14

    10 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 7.1 OUTPUT OPTIONS This function allows you to program the panel's Bell Output functions and certain Output options. Switched Ground (open collector) outputs are available from the XR10 when using a 4-wire output harness (Model 300 Harness). Refer to the ...

  • DMP Electronics Command Processor Panel - page 15

    11 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 7.5 OUTPUT ACTION This option allows you to define the operation of the panel's four annunciator outputs. 7.5A CUTOFF OUTPUTS Any or all of the available outputs can be programmed here to turn off after the time specified in OUTPUT CUTOFF TIME . See sect ...

  • DMP Electronics Command Processor Panel - page 16

    12 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 8.1 ZONE INFORMATION This allows you to define the operation of each protection zone used in the system. A description of each programming option follows: 8.2 ZONE NUMBER Enter the number of the zone you intend to program. Press COMMAND to enter a zone name. ...

  • DMP Electronics Command Processor Panel - page 17

    13 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 8.6 ARM AREAS This option specifies the areas to be armed by the Arming Type Zone. When disarmed, all areas in the system are disarmed. PERIMETER/ALL - Specify whether the arming zone arms just the Perimeter (PERIM) or the Perimeter and Interior areas (ALL) f ...

  • DMP Electronics Command Processor Panel - page 18

    14 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 8.9A MESSAGE TO TRANSMIT You can send two report types to the receiver: Alarm and Trouble. These are represented by the characters A and T . Press any top row SELECT key to display the zone's report options. ALARM - Selecting A, allows an alarm report to ...

  • DMP Electronics Command Processor Panel - page 19

    15 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 8.11 ENTRY DELAY Select the entry delay timer for this zone. Entry delay timers 1 and 2 are programmed in section 6.4. 8.12 CROSS ZONE Select YES to enable cross zoning for this zone. Cross zoning requires this zone to trip twice, or this zone and another cro ...

  • DMP Electronics Command Processor Panel - page 20

    16 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 9.1 STOP At the STOP prompt, pressing any SELECT key allows you to exit the XR10 Programmer. When selected, the panel performs an internal reset and exits the programmer. The Stop function causes the following to occur: • The system is DISARMED • The pane ...

  • DMP Electronics Command Processor Panel - page 21

    17 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 11.1 Status List The Status List is the current status of the system or records of recent system events that are displayed on the alphanumeric keypads. For example, in Home/Away systems, you might see the display SYSTEM READY . This would be the current statu ...

  • DMP Electronics Command Processor Panel - page 22

    18 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 11.4 Zone Type Specifications This section describes applications for the default zone types in Zone Information programming. The XR10 panel contains 11 default zone types for use in configuring the system. These zone types provide the most commonly selected ...

  • DMP Electronics Command Processor Panel - page 23

    19 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 11.5 Zone Type Descriptions NT (Night Zone) - Controlled instant zone used for perimeter doors and windows and interior devices such as PIRs and Glassbreak detectors. DY (Day zone) - Used for emergency doors or fire doors to sound the keypad buzzer and displa ...

  • DMP Electronics Command Processor Panel - page 24

    20 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 11.7 Default panel programming This program sheets shows the XR10 panel's default program settings. Figure A1: XR10 Factory Default Program 11 - APPENDIX Name Account Number Phone Date Address City State Zip SYSTEM OPTIONS All/Perimeter NO YES Closing Co ...

  • DMP Electronics Command Processor Panel - page 25

    21 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 11.8 4-2 Communication Reports The table below contains a complete list of hexadecimal characters sent using the DMP 4-2 communication format. 11.9 How to Read this Table The first column on the left is the first digit of the 2-digit event code sent to the re ...

  • DMP Electronics Command Processor Panel - page 26

    22 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 11.10 4-2 Examples The following examples are the actual event codes a central station would receive. The full report would also include the account number and checksum. When the central station receives this event code It means 1A A Fire alarm is being repor ...

Производитель DMP Electronics Категория Home Security System

Документы, которые мы получаем от производителя устройства DMP Electronics Command Processor Panel мы можем разделить на несколько групп. Это в частности:
- технические чертежи DMP Electronics
- инструкции обслуживания Command Processor Panel
- паспорта изделия DMP Electronics
- информационные брошюры
- энергетические этикетки DMP Electronics Command Processor Panel
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания DMP Electronics Command Processor Panel.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа DMP Electronics Command Processor Panel, инструкции обслуживания, короткие инструкции или инструкции пользователя DMP Electronics Command Processor Panel. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия DMP Electronics Command Processor Panel.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства DMP Electronics Command Processor Panel, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании DMP Electronics Command Processor Panel пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей DMP Electronics Command Processor Panel.

Полная инструкция обслуживания DMP Electronics, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией DMP Electronics Command Processor Panel - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания DMP Electronics Command Processor Panel, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся DMP Electronics Command Processor Panel, которое найдем в данном документе
3. Советы по использованию основных функций устройства DMP Electronics Command Processor Panel - которые должны облегчить нам первые шаги во время использования DMP Electronics Command Processor Panel
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем DMP Electronics Command Processor Panel
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра DMP Electronics Command Processor Panel в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся DMP Electronics Command Processor Panel?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с DMP Electronics Command Processor Panel, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с DMP Electronics Command Processor Panel со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)