    INSTRUCTION MANUAL CS1 15 Barometric Pressure Sensor 3/03 Copyright (c) 2002-2003 Campbell Scientific, Inc. ...

  • Campbell Hausfeld CS115 - page 2

    Warranty and Assistance The CS115 BAROMETR IC PRESS URE SE NSOR is w arranted by CAMPBELL SCIENTIFIC, INC. to be f ree from def ects in m aterials and workmanship und er no rmal use a nd ser vice fo r twelve ( 12 ) months fr om date of shipment unle ss spec ified othe rwise. B atte ries ha ve no warr anty. CAMP BE LL SCIENTIFIC, INC.' s obliga ...

  • Campbell Hausfeld CS115 - page 3

    i CS115 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to specific sections. 1. Introducti on ................................................................. 1 2. Specifications ............................................................. 2 2.1 ...

  • Campbell Hausfeld CS115 - page 4

    This is a blank page. ...

  • Campbell Hausfeld CS115 - page 5

    1 CS115 Barometric Pressure Sensor The CS115 Barometric Pressure Sensor us es the resonant silicon technology pressure sensor developed by Druck. The sensor outputs a variable frequency which can be measured using the datalogger' s period averaging instruction or pulse count instruction. The entire process is essentially digital from sensor el ...

  • Campbell Hausfeld CS115 - page 6

    CS115 Barometric Pr essure Sensor 2 2. Specifications 2.1 Performance Measurem ent R ange: 600 mb t o 1100 mb (hPa) Operating Tem perature Range: -40°C to +60°C Hum idity Ran ge: non- condens ing Media Compatibility: non-corrosive gas Total Accuracy 1 : at 20°C ±0.3 mb -10°C to +50°C ±0.5 mb -20°C to +60°C ±1.5 mb -40°C to +60°C ±2.0 m ...

  • Campbell Hausfeld CS115 - page 7

    CS115 Barometric Pr essure Sensor 3 3. Installation 3.1 Venting and Condensati on To p revent condensation, install the se nsor in an en vironm entally protected enclosure, com plete w ith desiccant w hich should be chan ged at regular intervals. A s the sen sor mus t detect the external am bient pressu re the enclosu re mus t not be ‘hermeticall ...

  • Campbell Hausfeld CS115 - page 8

    CS115 Barometric Pr essure Sensor 4 As y ou m ount the sen sor onto the back plate of the enclosu re, place the fork lu g under the m ountin g screw to accomplish the proper groun ding of the s ensor as show n i n Fig ure 3-1. 3.3 Jumper Settings The CS115 ha s tw o operating m odes, ‘ contin uous’ and ‘tri ggered’ . It is norm ally shipped ...

  • Campbell Hausfeld CS115 - page 9

    CS115 Barometric Pr essure Sensor 5 4. Wiring The CS115 w iring instru ctions f or the exam ple program s are sh own in Table 4-1. For datal oggers C R500, CR510, C R10(X), CR 23X, and CR5000, analog ch annel is us ed for period averagin g meas uremen t. For CR7, 21X and CR9000 pu lse chann el is us ed for pulse cou nt m easurem ent. TABLE 4-1. Wir ...

  • Campbell Hausfeld CS115 - page 10

    CS115 Barometric Pr essure Sensor 6 Once th e CS115 is tu rned on one m inu te before every hour, an d the correct measu rement is m ade, it is then copied into the current variable called "Pressure" . The sensor is then turned off im m ediately follow ing the meas uremen t. In thi s exam ple, the CR 5000 measu res the CS 115 once every h ...

  • Campbell Hausfeld CS115 - page 11

    CS115 Barometric Pr essure Sensor 7 5.1 Period Averaging Measurement Examples 5.1.1 Period Averaging Measurement Example fo r CR10(X) EXAMPLE 1. Sam ple Program for CR 10(X) ;{CR 10X} ; *Table 1 Prog ram 01: 1 Execution Interval (seconds ) ;Turn on C S115 one m inut e before the h our ; 1: If tim e is (P92) 1: 59 Minutes (Seconds --) in to a 2: 60 ...

  • Campbell Hausfeld CS115 - page 12

    CS115 Barometric Pr essure Sensor 8 8: Sam ple (P70) 1: 1 Reps 2: 1* Loc [ P_m b ] *Table 2 Prog ram 02: 0.0000 Execution In terval (secon ds) *Table 3 S ubroutin es End Program -Input Loca tio ns- 1 P_m b * Proper entries w ill vary w ith program an d datalogger channel, and input location assign ments. 5.1.2 Period Averaging Measurement Example f ...

  • Campbell Hausfeld CS115 - page 13

    CS115 Barometric Pr essure Sensor 9 ;T urn off CS1 15 ; 4: Do (P86) 1: 58* Set Port 8* Low 5: If tim e is (P92) 1: 0 Minutes (Secon ds --) in to a 2: 60 Interval (sam e un its as above) 3: 1 0 Set Out put Flag H igh (Flag 0 ) 6: Real Tim e (P77) 1: 0110 Day ,Hour/Mi nute (m idnig ht = 0000) 7: Sam ple (P70) 1: 1 Reps 2: 1* Loc [ P_m b ] *Table 2 Pr ...

  • Campbell Hausfeld CS115 - page 14

    CS115 Barometric Pr essure Sensor 10 3: Period A verage (SE) (P27) 1: 1 Reps 2: 14 200 kHz Max Freq @ 500 m V Peak to Peak, F req Output 3: 24* SE Chan nel 4: 10 No. of Cy cles 5: 5 Timeou t (unit s = 0.01 seconds) 6: 1* Loc [ P_m b ] 7: 1000 Mult 8: 0.0 Of fset ;T urn off CS1 15 ; 4: Do (P86) 1: 51* Set Port 1* Low 5: End (P95) 6: If tim e is (P92 ...

  • Campbell Hausfeld CS115 - page 15

    CS115 Barometric Pr essure Sensor 11 5.1.4 Period Averaging Measurement Example fo r CR5000 in a Fast Executing Program at 10Hz EXAMPLE 4. Sam pl e Program for C R5000 ‘CR5000 ' 'Sample Progr am to Measure C S115 Barometri c Pressur e Sensor ' ' Public CS115_Freq, Pressu re Units Pressure = mb Begi nPr og Scan (100,m Sec,3,0) ...

  • Campbell Hausfeld CS115 - page 16

    CS115 Barometric Pr essure Sensor 12 5.2 Pulse Count Measure ment Exampl e 5.2.1 Pulse Count Measu rement Example for 21X EXAMPLE 5. Sam ple Program for 21X ;{21X} ; *Table 1 Prog ram 01: 1 Execution Interval (seconds ) 1: If tim e is (P92) 1: 59 Minu tes into a 2: 60 Minu te Interval 3: 46* Set Port 6* Hig h 2: If tim e is (P92) 1: 0 Minutes into ...

  • Campbell Hausfeld CS115 - page 17

    CS115 Barometric Pr essure Sensor 13 *Table 3 S ubroutin es End Program -Input Loca tio ns- 1 P_mb 1 1 1 * Proper entries w ill vary w ith program an d datalogger channel, and input location assign ments. 5.3 Output Resolution When s toring th e valu es from the CS115 t o a datalogger’ s fin al storage location, or to a da ta table, care must be ...

  • Campbell Hausfeld CS115 - page 18

    CS115 Barometric Pr essure Sensor 14 The corrections in volved can be signi ficant: e.g ., at 1000 mb an d 20°C, barometric pressure w ill decrease by 1.1 mb for ev ery 10 meter in crease in altitude. 7. Maintenance and Calibration Since the sen sor is sem i-sealed, m inim um m aintenan ce is required. 1. Visually inspect the cable conn ectio n to ...

  • Campbell Hausfeld CS115 - page 19

    Thi s is a b lank p age . ...

  • Campbell Hausfeld CS115 - page 20

    Campbell Scie ntific Com panies Campbell Scientific, Inc. (CS I) 815 West 1 800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campb ellsci.com Campbell Scientif ic Africa Pty. Ltd. (CSAf) PO B ox 24 50 Somers et West 7129 SOUTH AFRICA www.csafrica.co.za sales@csafrica.co.za Campbell Scientific Au st ralia Pt y. Ltd. (CSA) PO B ox 4 ...

Производитель Campbell Hausfeld Категория Marine Instruments

Документы, которые мы получаем от производителя устройства Campbell Hausfeld CS115 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Campbell Hausfeld
- инструкции обслуживания CS115
- паспорта изделия Campbell Hausfeld
- информационные брошюры
- энергетические этикетки Campbell Hausfeld CS115
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Campbell Hausfeld CS115.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Campbell Hausfeld CS115, инструкции обслуживания, короткие инструкции или инструкции пользователя Campbell Hausfeld CS115. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Campbell Hausfeld CS115.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Campbell Hausfeld CS115, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Campbell Hausfeld CS115 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Campbell Hausfeld CS115.

Полная инструкция обслуживания Campbell Hausfeld, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Campbell Hausfeld CS115 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Campbell Hausfeld CS115, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Campbell Hausfeld CS115, которое найдем в данном документе
3. Советы по использованию основных функций устройства Campbell Hausfeld CS115 - которые должны облегчить нам первые шаги во время использования Campbell Hausfeld CS115
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Campbell Hausfeld CS115
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Campbell Hausfeld CS115 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Campbell Hausfeld CS115?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Campbell Hausfeld CS115, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Campbell Hausfeld CS115 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)