Инструкция обслуживания Omega FMG3000

16 страниц 0.73 mb
Скачать

Перейти на страницу of 16

Summary
  • Omega FMG3000 - page 1

    Shop online at FMG-3000 S ERIES Blind version Magmeter U ser ’ s Guide ome ga.com om e g a .c om TM ® www .omega.com e-mail: http://omegamanual.info For latest information and product manual visit www .omegamanual.info. ISO 9001 CERTIFIED CORPORA TE QUALITY ST AMFORD , CT ISO 9002 CERTIFIED CORPORA TE QUALITY MANCHESTER, UK ...

  • Omega FMG3000 - page 2

    It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certifi cation of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certifi cation. The information contained in this document is believed to be correct, but ...

  • Omega FMG3000 - page 3

    1 1 2 3 4 JP2 FREQUENCY OUT DO NOT REMOVE Connect output signals and power to this 4-terminal block. 2. 4. 3. 3. Sensor T ype Pipe Size Jumper Position ½ in. to 2½ in. FMG3001 DN15 to DN65 FMG3002 3 in. to 4 in. DN80 to DN100 FMG3101 5 in. to 6 in. FMG3102 DN125 to DN150 8 in. DN200 FMG3201 10 in. to 12 in. FMG3202 DN250 to DN300 1. Omega FMG-300 ...

  • Omega FMG3000 - page 4

    2 SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confi rm chemical compatibility before use. 3. Do not exceed maximum temperature/pressure specifi cations. 4. Wear safety goggles or face shield during installation/service. 5. Do not alter product construction. 6. Disconnect power before attempting any ser ...

  • Omega FMG3000 - page 5

    3 4. Selecting a Location • The FMG-3000 requires a full pipe and a fully developed turbulent fl ow profi le for accurate measurement. • If the piping system harbors air pockets or bubbles, take steps to locate the sensor so the air pockets will not contact the electrodes. • In vertical installations, assemble the unit so the conduit ports ...

  • Omega FMG3000 - page 6

    4 Important: • The directional arrow on the body of the sensor must be pointed DOWNSTREAM. • The FLOW arrow decal can be placed directly on the pipe to identify the direction of fl ow . • Use a cable gland or a liquid tight connector to seal the cable ports from water intrusion. • The yellow housing may be reversed to align the conduit por ...

  • Omega FMG3000 - page 7

    5 6. General Installation and Grounding Tips Sensor conditioning The Magmeter output signal may be unstable immediately after installation. Allowing the sensor to soak in a full pipe (or in a ny container of water) for 24 hours will stabilize the performance. • V ery low conductivity fl uids may require a longer conditioning period. (The Magmete ...

  • Omega FMG3000 - page 8

    6 • The FMG-3001 and FMG-3101 Magmeters output an open collector frequency signal. • A 10 K Ω pull up resistor must be connected between terminals 1 and 2 if the magmeter is used with third-party equipment.. 8. Wiring the FMG-3001 and FMG-3101 with Frequency output 1 2 3 4 5-24 VDC Ground Not used Frequency Out Magmeter 10K Ω Install a pull ...

  • Omega FMG3000 - page 9

    7 9. Calibration Data: K-factors* and Full Scale Current V alues Plastic Installation Fittings: PVC T ees and Saddles PIPE SIZE FITTING K-Factor K-Factor 20 mA= 20 mA= (IN.) TYPE Gallons Liters* in GPM in LPM SCH 80 PVC TEES FOR SCH 80 PVC PIPE ½ FP-5305 2289.37 604.85 13.10 49.60 ¾ FP-5307 1430.41 377.92 20.97 79.38 1 FP-5310 876.86 231.67 34.21 ...

  • Omega FMG3000 - page 10

    8 PIPE SIZE FITTING K-Factor K-Factor 20 mA= 20 mA= (IN.) TYPE Gallons Liters* in GPM in LPM POL YPROPYLENE FITTINGS (DIN/ISO ,BS, ANSI) ½ FP-5105PO 2192.73 579.32 13.68 51.78 ¾ FP-5107PO 1327.81 350.81 22.59 85.52 1 FP-51 10PO 737.16 194.76 40.70 154.04 1¼ FP-51 12PO 453.46 1 19.81 66.16 250.41 1½ FP-51 15PO 275.03 72.66 109.08 412.86 2 FP-512 ...

  • Omega FMG3000 - page 11

    9 PIPE SIZE FITTING K-Factor K-Factor 20 mA= 20 mA= (IN.) TYPE Gallons Liters* in GPM in LPM CARBON STEEL TEES ON SCH 40 PIPE ½ FMG-5305CS 1572.66 415.50 19.08 72.20 ¾ FMG-5307CS 1086.73 287.1 1 27.61 104.49 1 FMG-5310CS 582.34 153.86 51.52 194.99 1¼ FMG-5312CS 377.48 99.73 79.48 300.81 1½ FMG-5315CS 267.79 70.75 1 12.03 424.02 2 FMG-5320CS 167 ...

  • Omega FMG3000 - page 12

    10 PIPE SIZE FITTING K-Factor K-Factor 20 mA= 20 mA= (IN.) TYPE Gallons Liters* in GPM in LPM BRONZE TEES ON SCH 40 PIPE 1 FP-5310BR 582.34 153.86 51.52 194.99 1¼ FP-5312BR 330.54 87.33 90.76 343.53 1½ FP-5315BR 254.76 67.31 1 17.76 445.71 2 FP-5320BR 157.36 41.58 190.64 721.58 COPPER TEES FITTING ON COPPER PIPE SCH K ½ FP-5305CU 2459.19 649.72 ...

  • Omega FMG3000 - page 13

    11 • Conductivity is less than 20 µS/cm. • Electronic component failure. • 4-20 mA is not scaled same as Loop device. • Loop device is not scaled same as Magmeter . • Range Jumper not placed correctly . • Defective Magmeter • Magmeter installed too close to upstream obstruction. • Magmeter electrodes are coated with solids. • Mag ...

  • Omega FMG3000 - page 14

    12 1 1. Ordering Information OMEGAMAG with Frequency Output FMG3001-PP OMEGAMAG, Blind, Freq, PP/316SS, ½-4 FMG3101-PP OMEGAMAG, Blind, Freq, PP/316SS, 5-8 FMG3201-PP OMEGAMAG, Blind, Freq, PP/316SS,10-12 FMG-3001-PVDF-HA OMEGAMAG, Blind, Freq, PVDF/Hast, ½-4 FMG3101-PVDF-HA OMEGAMAG, Blind, Freq, PVDF/Hast, 5-8 FMG3201-PVDF-HA OMEGAMAG, Blind, F ...

  • Omega FMG3000 - page 15

    W ARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA ’s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA ’s customers ...

  • Omega FMG3000 - page 16

    6-2551.090-OM (C-4/07) M-4210/0407 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at www .omega.com TEMPERATURE • Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies • Wire: Thermocouple, RTD & Thermistor • Calibrators & Ice Point References • Recorder ...

Производитель Omega Категория Camera Accessories

Документы, которые мы получаем от производителя устройства Omega FMG3000 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Omega
- инструкции обслуживания FMG3000
- паспорта изделия Omega
- информационные брошюры
- энергетические этикетки Omega FMG3000
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Omega FMG3000.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Omega FMG3000, инструкции обслуживания, короткие инструкции или инструкции пользователя Omega FMG3000. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Omega FMG3000.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Omega FMG3000, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Omega FMG3000 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Omega FMG3000.

Полная инструкция обслуживания Omega, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Omega FMG3000 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Omega FMG3000, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Omega FMG3000, которое найдем в данном документе
3. Советы по использованию основных функций устройства Omega FMG3000 - которые должны облегчить нам первые шаги во время использования Omega FMG3000
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Omega FMG3000
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Omega FMG3000 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Omega FMG3000?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Omega FMG3000, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Omega FMG3000 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)