    INST ALLA TION INSTRUCTIONS W ARNING These instructions are intended as an aid to qualified licensed service personnel for proper installation, adjust- ment and operation of this unit. Read these instructions thoroughly before attempting installation or operation. Failure to follow these instructions may result in improper installation, adjustment, ...

  • Heat Controller CDG SERIES - page 2

    Cased/Uncased Coils INST ALLA TION INSTRUCTIONS Heat Contr oller , Inc. 1 1.0 MODEL NOMENCLA TURE .....................................................................................2 2.0 SAFETY ...................................................................................................................3 3.0 GENERAL ......................... ...

  • Heat Controller CDG SERIES - page 3

    Heat Contr oller , Inc. INST ALLA TION INSTRUCTIONS Cased/Uncased Coils 2 1.0 Model Nomenclature C D G 18 F A - A C = Uncased Coil M = Multi Postion Cased Coil Design Series R-410A Refrigerant 18 = 18,000 BTUH 24 = 24,000 BTUH 30 = 30,000 BTUH 36 = 36,000 BTUH 42 = 42,000 BTUH 48 = 48,000 BTUH 60 = 60,000 BTUH F = Flowrater (Piston) T = TXV A = 14 ...

  • Heat Controller CDG SERIES - page 4

    Cased/Uncased Coils INST ALLA TION INSTRUCTIONS Heat Contr oller , Inc. 3 When you see the symbols below on labels or in manual, be alert to the potential or immediate hazards of personal injury , property and/or product damage. It is the owner ’s or installer ’s responsibility to comply with all safety instructions and information accompanying ...

  • Heat Controller CDG SERIES - page 5

    Heat Contr oller , Inc. INST ALLA TION INSTRUCTIONS Cased/Uncased Coils 4 The unit can be positioned for bottom return air in the upow position, left and right return in the horizon - tal position, top return in downow position. 3.1 Codes & Regulations This product is designed and manufactured to comply with national codes. Installation i ...

  • Heat Controller CDG SERIES - page 6

    Cased/Uncased Coils INST ALLA TION INSTRUCTIONS Heat Contr oller , Inc. 5 AUXILIARY DRAIN CONNECTION 3/4'' NPT FEMALE PIPE THREAD 3/4'' NPT FEMALE PIPE T HREAD A W 21'' 20'' W1 19'' H V APOR LINE CONNECTION COPPER (SWEAT ) LIQUID LINE CONNECTION COPPER (SWEAT ) COIL ACCESS P ANEL HORIZONT AL DRAIN C ...

  • Heat Controller CDG SERIES - page 7

    Heat Contr oller , Inc. INST ALLA TION INSTRUCTIONS Cased/Uncased Coils 6 H The Max.resistant pressure of evaporator is up to 16MPa (2320PSI) TOP AIR STOP LIQUID LINE CONNECTION V APOR LINE CONNECTION W D AUXILIARY DRAIN CONNECTION 3/4'' NPT FEMALE PIPE THREAD PRIMARY DRAIN CONNETION 3/4'' NPT FEMALE PIPE THREAD The Max. pressur ...

  • Heat Controller CDG SERIES - page 8

    Cased/Uncased Coils INST ALLA TION INSTRUCTIONS Heat Contr oller , Inc. 7 4.0 Installation Instructions 4.1 Parts Contact your distributor for authorized replacement parts. 4.2 Pre-Installation Instructions Carefully read all instructions for installation prior to installing product. Make sure each step or procedure is understood and any special co ...

  • Heat Controller CDG SERIES - page 9

    Heat Contr oller , Inc. INST ALLA TION INSTRUCTIONS Cased/Uncased Coils 8 5.0 Drain Applications 5.1 Condensate Drain Piping Consult local codes for special requirements. T o provide extra protection from water damage, install an additional auxiliary drain pan, provided by installer under the entire unit with a separate drain line. Manufacturer wil ...

  • Heat Controller CDG SERIES - page 10

    Cased/Uncased Coils INST ALLA TION INSTRUCTIONS Heat Contr oller , Inc. 9 Drain pan has two drain connections on each side to provide exibility of connection and drainage. Make sure pan has proper pitch and plugged if second connection is not used. It is highly recommended to use the secondary drain line to prevent overow when the primary dra ...

  • Heat Controller CDG SERIES - page 11

    Heat Contr oller , Inc. INST ALLA TION INSTRUCTIONS Cased/Uncased Coils 10 6.0 Refrigerant Connections T o prevent refrigerant leak, use proper tools to ensure clean, burr-free cut. Use brazing shield when welding close to the cabinet surface and wet rag to protect rubber grommet. Brazing alloy should be at least 5% silver content. 6.1 Flowrator Pi ...

  • Heat Controller CDG SERIES - page 12

    Cased/Uncased Coils INST ALLA TION INSTRUCTIONS Heat Contr oller , Inc. 1 1 Condensing Unit Model No. HCI Indoor Coil PISTON SIZE Cased Coil Uncased Coil RSG18S-1D RSG18R-1D MDG18F A -A CDG18F A - A 0.050 MDG18FB-A CDG18FB- A RSG2 4S-1D RSG2 4R-1D MDG2 4F A- A CDG2 4F A - A 0.053 MDG2 4FB- A CDG2 4FB- A RSG30S-1D RSG30R-1D MDG30F A -A CDG30FA-A 0.0 ...

  • Heat Controller CDG SERIES - page 13

    04/2009 0 7 /201 1 ...

Produzent Heat Controller Kategorie Heat Pump

Dokumente, die wir vom Produzenten des Geräts Heat Controller CDG SERIES erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Heat Controller
- Bedienungsanleitungen CDG SERIES
- Produktkarten Heat Controller
- Informationsbroschüren
- oder Energieetiketten Heat Controller CDG SERIES
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Heat Controller CDG SERIES.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Heat Controller CDG SERIES, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Heat Controller CDG SERIES. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Heat Controller CDG SERIES ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Heat Controller CDG SERIES, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Heat Controller CDG SERIES hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Heat Controller CDG SERIES verständlich ist.

Eine gänzliche Bedienungsanleitung von Heat Controller sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Heat Controller CDG SERIES bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Heat Controller CDG SERIES befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Heat Controller CDG SERIES, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Heat Controller CDG SERIES - die uns die ersten Schritte während der Nutzung von Heat Controller CDG SERIES erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Heat Controller CDG SERIES hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Heat Controller CDG SERIES im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Heat Controller CDG SERIES?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Heat Controller CDG SERIES nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Heat Controller CDG SERIES hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)