Heat Controller CDG SERIESの取扱説明書

13ページ 1.21 mb
ダウンロード

ページに移動 of 13

Summary
  • Heat Controller CDG SERIES - page 1

    INST ALLA TION INSTRUCTIONS W ARNING These instructions are intended as an aid to qualified licensed service personnel for proper installation, adjust- ment and operation of this unit. Read these instructions thoroughly before attempting installation or operation. Failure to follow these instructions may result in improper installation, adjustment, ...

  • Heat Controller CDG SERIES - page 2

    Cased/Uncased Coils INST ALLA TION INSTRUCTIONS Heat Contr oller , Inc. 1 1.0 MODEL NOMENCLA TURE .....................................................................................2 2.0 SAFETY ...................................................................................................................3 3.0 GENERAL ......................... ...

  • Heat Controller CDG SERIES - page 3

    Heat Contr oller , Inc. INST ALLA TION INSTRUCTIONS Cased/Uncased Coils 2 1.0 Model Nomenclature C D G 18 F A - A C = Uncased Coil M = Multi Postion Cased Coil Design Series R-410A Refrigerant 18 = 18,000 BTUH 24 = 24,000 BTUH 30 = 30,000 BTUH 36 = 36,000 BTUH 42 = 42,000 BTUH 48 = 48,000 BTUH 60 = 60,000 BTUH F = Flowrater (Piston) T = TXV A = 14 ...

  • Heat Controller CDG SERIES - page 4

    Cased/Uncased Coils INST ALLA TION INSTRUCTIONS Heat Contr oller , Inc. 3 When you see the symbols below on labels or in manual, be alert to the potential or immediate hazards of personal injury , property and/or product damage. It is the owner ’s or installer ’s responsibility to comply with all safety instructions and information accompanying ...

  • Heat Controller CDG SERIES - page 5

    Heat Contr oller , Inc. INST ALLA TION INSTRUCTIONS Cased/Uncased Coils 4 The unit can be positioned for bottom return air in the upow position, left and right return in the horizon - tal position, top return in downow position. 3.1 Codes & Regulations This product is designed and manufactured to comply with national codes. Installation i ...

  • Heat Controller CDG SERIES - page 6

    Cased/Uncased Coils INST ALLA TION INSTRUCTIONS Heat Contr oller , Inc. 5 AUXILIARY DRAIN CONNECTION 3/4'' NPT FEMALE PIPE THREAD 3/4'' NPT FEMALE PIPE T HREAD A W 21'' 20'' W1 19'' H V APOR LINE CONNECTION COPPER (SWEAT ) LIQUID LINE CONNECTION COPPER (SWEAT ) COIL ACCESS P ANEL HORIZONT AL DRAIN C ...

  • Heat Controller CDG SERIES - page 7

    Heat Contr oller , Inc. INST ALLA TION INSTRUCTIONS Cased/Uncased Coils 6 H The Max.resistant pressure of evaporator is up to 16MPa (2320PSI) TOP AIR STOP LIQUID LINE CONNECTION V APOR LINE CONNECTION W D AUXILIARY DRAIN CONNECTION 3/4'' NPT FEMALE PIPE THREAD PRIMARY DRAIN CONNETION 3/4'' NPT FEMALE PIPE THREAD The Max. pressur ...

  • Heat Controller CDG SERIES - page 8

    Cased/Uncased Coils INST ALLA TION INSTRUCTIONS Heat Contr oller , Inc. 7 4.0 Installation Instructions 4.1 Parts Contact your distributor for authorized replacement parts. 4.2 Pre-Installation Instructions Carefully read all instructions for installation prior to installing product. Make sure each step or procedure is understood and any special co ...

  • Heat Controller CDG SERIES - page 9

    Heat Contr oller , Inc. INST ALLA TION INSTRUCTIONS Cased/Uncased Coils 8 5.0 Drain Applications 5.1 Condensate Drain Piping Consult local codes for special requirements. T o provide extra protection from water damage, install an additional auxiliary drain pan, provided by installer under the entire unit with a separate drain line. Manufacturer wil ...

  • Heat Controller CDG SERIES - page 10

    Cased/Uncased Coils INST ALLA TION INSTRUCTIONS Heat Contr oller , Inc. 9 Drain pan has two drain connections on each side to provide exibility of connection and drainage. Make sure pan has proper pitch and plugged if second connection is not used. It is highly recommended to use the secondary drain line to prevent overow when the primary dra ...

  • Heat Controller CDG SERIES - page 11

    Heat Contr oller , Inc. INST ALLA TION INSTRUCTIONS Cased/Uncased Coils 10 6.0 Refrigerant Connections T o prevent refrigerant leak, use proper tools to ensure clean, burr-free cut. Use brazing shield when welding close to the cabinet surface and wet rag to protect rubber grommet. Brazing alloy should be at least 5% silver content. 6.1 Flowrator Pi ...

  • Heat Controller CDG SERIES - page 12

    Cased/Uncased Coils INST ALLA TION INSTRUCTIONS Heat Contr oller , Inc. 1 1 Condensing Unit Model No. HCI Indoor Coil PISTON SIZE Cased Coil Uncased Coil RSG18S-1D RSG18R-1D MDG18F A -A CDG18F A - A 0.050 MDG18FB-A CDG18FB- A RSG2 4S-1D RSG2 4R-1D MDG2 4F A- A CDG2 4F A - A 0.053 MDG2 4FB- A CDG2 4FB- A RSG30S-1D RSG30R-1D MDG30F A -A CDG30FA-A 0.0 ...

  • Heat Controller CDG SERIES - page 13

    04/2009 0 7 /201 1 ...

メーカー Heat Controller カテゴリー Heat Pump

Heat Controller CDG SERIESのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CDG SERIESの取扱説明書
- Heat Controllerの製品カード
- パンフレット
- またはHeat Controller CDG SERIESの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Heat Controller CDG SERIESの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Heat Controller CDG SERIESの取り付け説明書、サービスマニュアル、簡易説明書、またはHeat Controller CDG SERIESのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Heat Controller CDG SERIESの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Heat Controller CDG SERIESデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHeat Controller CDG SERIESを使用するのを助ける技術的文書のことです。説明書は通常、全てのHeat Controller CDG SERIESユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Heat Controllerの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Heat Controller CDG SERIESの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHeat Controller CDG SERIESの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Heat Controller CDG SERIESに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Heat Controller CDG SERIESデバイスの基本機能を使うにあたってのヒント。 Heat Controller CDG SERIESのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Heat Controller CDG SERIESに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHeat Controller CDG SERIESのメーカー/サービスへの連絡先に関する情報。

Heat Controller CDG SERIESについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHeat Controller CDG SERIESの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHeat Controller CDG SERIESで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)