    INST ALLA TION INSTRUCTIONS W ARNING These instructions are intended as an aid to qualified licensed service personnel for proper installation, adjust- ment and operation of this unit. Read these instructions thoroughly before attempting installation or operation. Failure to follow these instructions may result in improper installation, adjustment, ...

  • Heat Controller CDG SERIES - page 2

    Cased/Uncased Coils INST ALLA TION INSTRUCTIONS Heat Contr oller , Inc. 1 1.0 MODEL NOMENCLA TURE .....................................................................................2 2.0 SAFETY ...................................................................................................................3 3.0 GENERAL ......................... ...

  • Heat Controller CDG SERIES - page 3

    Heat Contr oller , Inc. INST ALLA TION INSTRUCTIONS Cased/Uncased Coils 2 1.0 Model Nomenclature C D G 18 F A - A C = Uncased Coil M = Multi Postion Cased Coil Design Series R-410A Refrigerant 18 = 18,000 BTUH 24 = 24,000 BTUH 30 = 30,000 BTUH 36 = 36,000 BTUH 42 = 42,000 BTUH 48 = 48,000 BTUH 60 = 60,000 BTUH F = Flowrater (Piston) T = TXV A = 14 ...

  • Heat Controller CDG SERIES - page 4

    Cased/Uncased Coils INST ALLA TION INSTRUCTIONS Heat Contr oller , Inc. 3 When you see the symbols below on labels or in manual, be alert to the potential or immediate hazards of personal injury , property and/or product damage. It is the owner ’s or installer ’s responsibility to comply with all safety instructions and information accompanying ...

  • Heat Controller CDG SERIES - page 5

    Heat Contr oller , Inc. INST ALLA TION INSTRUCTIONS Cased/Uncased Coils 4 The unit can be positioned for bottom return air in the upow position, left and right return in the horizon - tal position, top return in downow position. 3.1 Codes & Regulations This product is designed and manufactured to comply with national codes. Installation i ...

  • Heat Controller CDG SERIES - page 6

    Cased/Uncased Coils INST ALLA TION INSTRUCTIONS Heat Contr oller , Inc. 5 AUXILIARY DRAIN CONNECTION 3/4'' NPT FEMALE PIPE THREAD 3/4'' NPT FEMALE PIPE T HREAD A W 21'' 20'' W1 19'' H V APOR LINE CONNECTION COPPER (SWEAT ) LIQUID LINE CONNECTION COPPER (SWEAT ) COIL ACCESS P ANEL HORIZONT AL DRAIN C ...

  • Heat Controller CDG SERIES - page 7

    Heat Contr oller , Inc. INST ALLA TION INSTRUCTIONS Cased/Uncased Coils 6 H The Max.resistant pressure of evaporator is up to 16MPa (2320PSI) TOP AIR STOP LIQUID LINE CONNECTION V APOR LINE CONNECTION W D AUXILIARY DRAIN CONNECTION 3/4'' NPT FEMALE PIPE THREAD PRIMARY DRAIN CONNETION 3/4'' NPT FEMALE PIPE THREAD The Max. pressur ...

  • Heat Controller CDG SERIES - page 8

    Cased/Uncased Coils INST ALLA TION INSTRUCTIONS Heat Contr oller , Inc. 7 4.0 Installation Instructions 4.1 Parts Contact your distributor for authorized replacement parts. 4.2 Pre-Installation Instructions Carefully read all instructions for installation prior to installing product. Make sure each step or procedure is understood and any special co ...

  • Heat Controller CDG SERIES - page 9

    Heat Contr oller , Inc. INST ALLA TION INSTRUCTIONS Cased/Uncased Coils 8 5.0 Drain Applications 5.1 Condensate Drain Piping Consult local codes for special requirements. T o provide extra protection from water damage, install an additional auxiliary drain pan, provided by installer under the entire unit with a separate drain line. Manufacturer wil ...

  • Heat Controller CDG SERIES - page 10

    Cased/Uncased Coils INST ALLA TION INSTRUCTIONS Heat Contr oller , Inc. 9 Drain pan has two drain connections on each side to provide exibility of connection and drainage. Make sure pan has proper pitch and plugged if second connection is not used. It is highly recommended to use the secondary drain line to prevent overow when the primary dra ...

  • Heat Controller CDG SERIES - page 11

    Heat Contr oller , Inc. INST ALLA TION INSTRUCTIONS Cased/Uncased Coils 10 6.0 Refrigerant Connections T o prevent refrigerant leak, use proper tools to ensure clean, burr-free cut. Use brazing shield when welding close to the cabinet surface and wet rag to protect rubber grommet. Brazing alloy should be at least 5% silver content. 6.1 Flowrator Pi ...

  • Heat Controller CDG SERIES - page 12

    Cased/Uncased Coils INST ALLA TION INSTRUCTIONS Heat Contr oller , Inc. 1 1 Condensing Unit Model No. HCI Indoor Coil PISTON SIZE Cased Coil Uncased Coil RSG18S-1D RSG18R-1D MDG18F A -A CDG18F A - A 0.050 MDG18FB-A CDG18FB- A RSG2 4S-1D RSG2 4R-1D MDG2 4F A- A CDG2 4F A - A 0.053 MDG2 4FB- A CDG2 4FB- A RSG30S-1D RSG30R-1D MDG30F A -A CDG30FA-A 0.0 ...

  • Heat Controller CDG SERIES - page 13

    04/2009 0 7 /201 1 ...

Manufacturer Heat Controller Category Heat Pump

Documents that we receive from a manufacturer of a Heat Controller CDG SERIES can be divided into several groups. They are, among others:
- Heat Controller technical drawings
- CDG SERIES manuals
- Heat Controller product data sheets
- information booklets
- or energy labels Heat Controller CDG SERIES
All of them are important, but the most important information from the point of view of use of the device are in the user manual Heat Controller CDG SERIES.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Heat Controller CDG SERIES, service manual, brief instructions and user manuals Heat Controller CDG SERIES. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Heat Controller CDG SERIES.

A complete manual for the device Heat Controller CDG SERIES, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Heat Controller CDG SERIES by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Heat Controller CDG SERIES.

A complete Heat Controller manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Heat Controller CDG SERIES - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Heat Controller CDG SERIES, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Heat Controller CDG SERIES, that we can find in the current document
3. Tips how to use the basic functions of the device Heat Controller CDG SERIES - which should help us in our first steps of using Heat Controller CDG SERIES
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Heat Controller CDG SERIES
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Heat Controller CDG SERIES in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Heat Controller CDG SERIES?

Use the form below

If you did not solve your problem by using a manual Heat Controller CDG SERIES, ask a question using the form below. If a user had a similar problem with Heat Controller CDG SERIES it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)