Bedienungsanleitung ATS HILT 9000

17 Seiten 0.12 mb
Download

Zur Seite of 17

Summary
  • ATS HILT 9000 - page 1

    HIL T 9000 Handheld Inductive Loop T ester User Manual July 2003 R=12.3 Ω Q=12.1 L=89.2µH 50KHz ATSI 8157 US Route 50 • Athens, OH 45701 (740) 592-2874 • Fax (740) 594-2875 sales@atsi-tester .com www.atsi-tester .com ...

  • ATS HILT 9000 - page 2

    1 HILT 9000 - Inductive Loop Tester T able of Contents Receiving Y our Shipment ......................................................... 2 Packaging ..... ........................................................................... 2 Description ............................................................................. 3 Overview of HIL T 9000 C ...

  • ATS HILT 9000 - page 3

    2 www.atsi-tester .com W a r nings These safety war ning are provided to ensure the safety of personnel and proper operation of the tester . • The tester must not be operated beyond its specified operating range. • Safety is the responsibility of the operator . Receiving your Shipment Upon receiving your shipment, be sure that the contents are ...

  • ATS HILT 9000 - page 4

    3 HILT 9000 - Inductive Loop Tester General Description The HILT -9000 is designed to measure characteristics of an inductive loop at dif ferent frequencies; measure working parameters of the loop system; as well as simulate the detector by measuring the change of inductance. The measurement modes can be easily switched by pressing corresponding bu ...

  • ATS HILT 9000 - page 5

    4 www.atsi-tester .com Overview of HIL T 9000 Contr ols 1. LOOP: Measures R DC , L, and Q . If Q >15, use Q push- button to obtain actual value. 2. Q : Measures high Q values (when Q is >15). 3. Used in SET FREQ mode to increase frequency by 1KHz. 4. Used in SET FREQ mode to decrease frequency by 1KHz. 5. POWER: Tur ns unit On/Off. 6. SET FRE ...

  • ATS HILT 9000 - page 6

    5 HILT 9000 - Inductive Loop Tester Function Controls Power Press the POWER push-button to tur n the tester on and off. The tester per for ms an initial self-test to verify that the inter nal circuit is working. After the self-test is complete, the tester shows the current battery level and the message: Ready: Select Function . If the battery is lo ...

  • ATS HILT 9000 - page 7

    6 www.atsi-tester .com The LOOP test can measure a maxi- mum Q of 15. If Q is greater than 15 the tester displays Q >15 . To measur e the actual value, press the Q button on the keypad to run a separate Q test. The default frequency at which the LOOP and Q tests run is 50 KHz. It can be changed to any value within the range from 20 KHz to 80 KHz ...

  • ATS HILT 9000 - page 8

    7 HILT 9000 - Inductive Loop Tester , , Set Frequency When the tester is powered, the test frequency is automatically set to 50 KHz. The frequency can be changed to any value between 20 KHz and 80 KHz with 1 KHz resolution. T o set a dif ferent fr equency press the SET FREQ push-button to view the fre- quency adjustment display as show in Figure 5. ...

  • ATS HILT 9000 - page 9

    8 www.atsi-tester .com If there is bad connection, the tester displays a message as shown in Figure 7. Make sure that the test leads are properly connected. If the leads are connected to the loop and the message is still present, it means that Q of the loop is too low to generate the oscilla- tion or the inductance is out of range. This can be veri ...

  • ATS HILT 9000 - page 10

    9 HILT 9000 - Inductive Loop Tester Function Controls Summary BUTTON DESC RIPTIO N COMMENTS LOOP Used to measure L, Q, and R DC of the loop. Q is measured up to 15. If Q> 15, use Q butt on to obtain th e actual v alue of Q The loop must be disconnected fro m the system to run th is test Q Used to m easure hig h Q values ( when Q is >15) The l ...

  • ATS HILT 9000 - page 11

    10 www.atsi-tester .com Overview of T raf fic Loop Detection Systems The inductive loop represents the most commonly used method to detect vehicles. The inductive loop is simply a coil of wires embedded into the pavement and can be characterized by several parameters, L (inductance), Q (quality factor), R (active resis- tance, measured using AC sig ...

  • ATS HILT 9000 - page 12

    11 HILT 9000 - Inductive Loop Tester To guarantee a reliable oscillation in the loop system the quality factor ( Q ) of the loop with the lead-in wires should be above some value, deter mined by the amplifiers inside the detector . Deterio- ration of the loop and lead-in wires reduces Q and eventually prevents the system from oscillating even with ...

  • ATS HILT 9000 - page 13

    12 www.atsi-tester .com Commonly Asked Questions Q . Why do I have to disconnect the detector from the loop before running a Loop , Q , or ∆ ∆ ∆ ∆ ∆ L test? A. During Loop, Q , and ∆ L test, the tester is applying its own signal to the loop. The tester verifies there is no signal on the loop before running these tests. However , with a ...

  • ATS HILT 9000 - page 14

    13 HILT 9000 - Inductive Loop Tester Repair and Calibration To ensure that your instrument meets factory specifications, we recommend that it be retur ned to our factory at one-year intervals for calibration service. In addition to calibration of the test parameters, this service includes replacement of batteries and fir mware updates. Please conta ...

  • ATS HILT 9000 - page 15

    14 www.atsi-tester .com T echnical and Sales Assistance If you are experiencing any technical problems, or require any assistance with the proper operation or application of your tester , please call, fax, or e-mail our technical support staf f: ATSI 8157 US Route 50 • Athens, OH 45701 (740) 592-2984 (740) 594-2875 - Fax service@atsi-tester .com ...

  • ATS HILT 9000 - page 16

    15 HILT 9000 - Inductive Loop Tester -- This page left blank -- ...

  • ATS HILT 9000 - page 17

    16 www.atsi-tester .com Limited W arranty The HIL T 9000 (“Product”), distributed by Athens Technical Specialists, Inc. (ATSI), is warranted to the original purchaser (“Purchaser”) to be free of defects in materials and workmanship for a period of one year from the purchase date stated on the invoice. Within this period, in the event of a d ...

Produzent ATS Kategorie Network Card

Dokumente, die wir vom Produzenten des Geräts ATS HILT 9000 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen ATS
- Bedienungsanleitungen HILT 9000
- Produktkarten ATS
- Informationsbroschüren
- oder Energieetiketten ATS HILT 9000
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung ATS HILT 9000.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen ATS HILT 9000, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen ATS HILT 9000. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts ATS HILT 9000 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts ATS HILT 9000, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von ATS HILT 9000 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von ATS HILT 9000 verständlich ist.

Eine gänzliche Bedienungsanleitung von ATS sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von ATS HILT 9000 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von ATS HILT 9000 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich ATS HILT 9000, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts ATS HILT 9000 - die uns die ersten Schritte während der Nutzung von ATS HILT 9000 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit ATS HILT 9000 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von ATS HILT 9000 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich ATS HILT 9000?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit ATS HILT 9000 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit ATS HILT 9000 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.