Manuale per l’uso ATS HILT 9000

17 pagine 0.12 mb
Scarica

Vai alla pagina of 17

Summary
  • ATS HILT 9000 - page 1

    HIL T 9000 Handheld Inductive Loop T ester User Manual July 2003 R=12.3 Ω Q=12.1 L=89.2µH 50KHz ATSI 8157 US Route 50 • Athens, OH 45701 (740) 592-2874 • Fax (740) 594-2875 sales@atsi-tester .com www.atsi-tester .com ...

  • ATS HILT 9000 - page 2

    1 HILT 9000 - Inductive Loop Tester T able of Contents Receiving Y our Shipment ......................................................... 2 Packaging ..... ........................................................................... 2 Description ............................................................................. 3 Overview of HIL T 9000 C ...

  • ATS HILT 9000 - page 3

    2 www.atsi-tester .com W a r nings These safety war ning are provided to ensure the safety of personnel and proper operation of the tester . • The tester must not be operated beyond its specified operating range. • Safety is the responsibility of the operator . Receiving your Shipment Upon receiving your shipment, be sure that the contents are ...

  • ATS HILT 9000 - page 4

    3 HILT 9000 - Inductive Loop Tester General Description The HILT -9000 is designed to measure characteristics of an inductive loop at dif ferent frequencies; measure working parameters of the loop system; as well as simulate the detector by measuring the change of inductance. The measurement modes can be easily switched by pressing corresponding bu ...

  • ATS HILT 9000 - page 5

    4 www.atsi-tester .com Overview of HIL T 9000 Contr ols 1. LOOP: Measures R DC , L, and Q . If Q >15, use Q push- button to obtain actual value. 2. Q : Measures high Q values (when Q is >15). 3. Used in SET FREQ mode to increase frequency by 1KHz. 4. Used in SET FREQ mode to decrease frequency by 1KHz. 5. POWER: Tur ns unit On/Off. 6. SET FRE ...

  • ATS HILT 9000 - page 6

    5 HILT 9000 - Inductive Loop Tester Function Controls Power Press the POWER push-button to tur n the tester on and off. The tester per for ms an initial self-test to verify that the inter nal circuit is working. After the self-test is complete, the tester shows the current battery level and the message: Ready: Select Function . If the battery is lo ...

  • ATS HILT 9000 - page 7

    6 www.atsi-tester .com The LOOP test can measure a maxi- mum Q of 15. If Q is greater than 15 the tester displays Q >15 . To measur e the actual value, press the Q button on the keypad to run a separate Q test. The default frequency at which the LOOP and Q tests run is 50 KHz. It can be changed to any value within the range from 20 KHz to 80 KHz ...

  • ATS HILT 9000 - page 8

    7 HILT 9000 - Inductive Loop Tester , , Set Frequency When the tester is powered, the test frequency is automatically set to 50 KHz. The frequency can be changed to any value between 20 KHz and 80 KHz with 1 KHz resolution. T o set a dif ferent fr equency press the SET FREQ push-button to view the fre- quency adjustment display as show in Figure 5. ...

  • ATS HILT 9000 - page 9

    8 www.atsi-tester .com If there is bad connection, the tester displays a message as shown in Figure 7. Make sure that the test leads are properly connected. If the leads are connected to the loop and the message is still present, it means that Q of the loop is too low to generate the oscilla- tion or the inductance is out of range. This can be veri ...

  • ATS HILT 9000 - page 10

    9 HILT 9000 - Inductive Loop Tester Function Controls Summary BUTTON DESC RIPTIO N COMMENTS LOOP Used to measure L, Q, and R DC of the loop. Q is measured up to 15. If Q> 15, use Q butt on to obtain th e actual v alue of Q The loop must be disconnected fro m the system to run th is test Q Used to m easure hig h Q values ( when Q is >15) The l ...

  • ATS HILT 9000 - page 11

    10 www.atsi-tester .com Overview of T raf fic Loop Detection Systems The inductive loop represents the most commonly used method to detect vehicles. The inductive loop is simply a coil of wires embedded into the pavement and can be characterized by several parameters, L (inductance), Q (quality factor), R (active resis- tance, measured using AC sig ...

  • ATS HILT 9000 - page 12

    11 HILT 9000 - Inductive Loop Tester To guarantee a reliable oscillation in the loop system the quality factor ( Q ) of the loop with the lead-in wires should be above some value, deter mined by the amplifiers inside the detector . Deterio- ration of the loop and lead-in wires reduces Q and eventually prevents the system from oscillating even with ...

  • ATS HILT 9000 - page 13

    12 www.atsi-tester .com Commonly Asked Questions Q . Why do I have to disconnect the detector from the loop before running a Loop , Q , or ∆ ∆ ∆ ∆ ∆ L test? A. During Loop, Q , and ∆ L test, the tester is applying its own signal to the loop. The tester verifies there is no signal on the loop before running these tests. However , with a ...

  • ATS HILT 9000 - page 14

    13 HILT 9000 - Inductive Loop Tester Repair and Calibration To ensure that your instrument meets factory specifications, we recommend that it be retur ned to our factory at one-year intervals for calibration service. In addition to calibration of the test parameters, this service includes replacement of batteries and fir mware updates. Please conta ...

  • ATS HILT 9000 - page 15

    14 www.atsi-tester .com T echnical and Sales Assistance If you are experiencing any technical problems, or require any assistance with the proper operation or application of your tester , please call, fax, or e-mail our technical support staf f: ATSI 8157 US Route 50 • Athens, OH 45701 (740) 592-2984 (740) 594-2875 - Fax service@atsi-tester .com ...

  • ATS HILT 9000 - page 16

    15 HILT 9000 - Inductive Loop Tester -- This page left blank -- ...

  • ATS HILT 9000 - page 17

    16 www.atsi-tester .com Limited W arranty The HIL T 9000 (“Product”), distributed by Athens Technical Specialists, Inc. (ATSI), is warranted to the original purchaser (“Purchaser”) to be free of defects in materials and workmanship for a period of one year from the purchase date stated on the invoice. Within this period, in the event of a d ...

Fabbricante ATS Categoria Network Card

I documenti che otteniamo dal fabbricante del dispositivoATS HILT 9000 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici ATS
- manuali per l’uso HILT 9000
- schede prodotto ATS
- opuscoli
- o etichette energetiche ATS HILT 9000
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso ATS HILT 9000.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione ATS HILT 9000, manuali di manutenzione, brevi manuali o manuali utente ATS HILT 9000. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto ATS HILT 9000.

Manuali per l’uso simili

Manuale completo del dispositivo ATS HILT 9000, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare ATS HILT 9000 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti ATS HILT 9000.

Il manuale per l’uso completo ATS, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale ATS HILT 9000 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice ATS HILT 9000, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per ATS HILT 9000 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo ATS HILT 9000 - che ci dovrebbe aiutare nei primi passi durante l'uso ATS HILT 9000
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del ATS HILT 9000
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio ATS HILT 9000 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su ATS HILT 9000?

Utilizza il modulo sottostante

Se non hai risolto il problema con ATS HILT 9000 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con ATS HILT 9000 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)