ATS HILT 9000の取扱説明書

17ページ 0.12 mb
ダウンロード

ページに移動 of 17

Summary
  • ATS HILT 9000 - page 1

    HIL T 9000 Handheld Inductive Loop T ester User Manual July 2003 R=12.3 Ω Q=12.1 L=89.2µH 50KHz ATSI 8157 US Route 50 • Athens, OH 45701 (740) 592-2874 • Fax (740) 594-2875 sales@atsi-tester .com www.atsi-tester .com ...

  • ATS HILT 9000 - page 2

    1 HILT 9000 - Inductive Loop Tester T able of Contents Receiving Y our Shipment ......................................................... 2 Packaging ..... ........................................................................... 2 Description ............................................................................. 3 Overview of HIL T 9000 C ...

  • ATS HILT 9000 - page 3

    2 www.atsi-tester .com W a r nings These safety war ning are provided to ensure the safety of personnel and proper operation of the tester . • The tester must not be operated beyond its specified operating range. • Safety is the responsibility of the operator . Receiving your Shipment Upon receiving your shipment, be sure that the contents are ...

  • ATS HILT 9000 - page 4

    3 HILT 9000 - Inductive Loop Tester General Description The HILT -9000 is designed to measure characteristics of an inductive loop at dif ferent frequencies; measure working parameters of the loop system; as well as simulate the detector by measuring the change of inductance. The measurement modes can be easily switched by pressing corresponding bu ...

  • ATS HILT 9000 - page 5

    4 www.atsi-tester .com Overview of HIL T 9000 Contr ols 1. LOOP: Measures R DC , L, and Q . If Q >15, use Q push- button to obtain actual value. 2. Q : Measures high Q values (when Q is >15). 3. Used in SET FREQ mode to increase frequency by 1KHz. 4. Used in SET FREQ mode to decrease frequency by 1KHz. 5. POWER: Tur ns unit On/Off. 6. SET FRE ...

  • ATS HILT 9000 - page 6

    5 HILT 9000 - Inductive Loop Tester Function Controls Power Press the POWER push-button to tur n the tester on and off. The tester per for ms an initial self-test to verify that the inter nal circuit is working. After the self-test is complete, the tester shows the current battery level and the message: Ready: Select Function . If the battery is lo ...

  • ATS HILT 9000 - page 7

    6 www.atsi-tester .com The LOOP test can measure a maxi- mum Q of 15. If Q is greater than 15 the tester displays Q >15 . To measur e the actual value, press the Q button on the keypad to run a separate Q test. The default frequency at which the LOOP and Q tests run is 50 KHz. It can be changed to any value within the range from 20 KHz to 80 KHz ...

  • ATS HILT 9000 - page 8

    7 HILT 9000 - Inductive Loop Tester , , Set Frequency When the tester is powered, the test frequency is automatically set to 50 KHz. The frequency can be changed to any value between 20 KHz and 80 KHz with 1 KHz resolution. T o set a dif ferent fr equency press the SET FREQ push-button to view the fre- quency adjustment display as show in Figure 5. ...

  • ATS HILT 9000 - page 9

    8 www.atsi-tester .com If there is bad connection, the tester displays a message as shown in Figure 7. Make sure that the test leads are properly connected. If the leads are connected to the loop and the message is still present, it means that Q of the loop is too low to generate the oscilla- tion or the inductance is out of range. This can be veri ...

  • ATS HILT 9000 - page 10

    9 HILT 9000 - Inductive Loop Tester Function Controls Summary BUTTON DESC RIPTIO N COMMENTS LOOP Used to measure L, Q, and R DC of the loop. Q is measured up to 15. If Q> 15, use Q butt on to obtain th e actual v alue of Q The loop must be disconnected fro m the system to run th is test Q Used to m easure hig h Q values ( when Q is >15) The l ...

  • ATS HILT 9000 - page 11

    10 www.atsi-tester .com Overview of T raf fic Loop Detection Systems The inductive loop represents the most commonly used method to detect vehicles. The inductive loop is simply a coil of wires embedded into the pavement and can be characterized by several parameters, L (inductance), Q (quality factor), R (active resis- tance, measured using AC sig ...

  • ATS HILT 9000 - page 12

    11 HILT 9000 - Inductive Loop Tester To guarantee a reliable oscillation in the loop system the quality factor ( Q ) of the loop with the lead-in wires should be above some value, deter mined by the amplifiers inside the detector . Deterio- ration of the loop and lead-in wires reduces Q and eventually prevents the system from oscillating even with ...

  • ATS HILT 9000 - page 13

    12 www.atsi-tester .com Commonly Asked Questions Q . Why do I have to disconnect the detector from the loop before running a Loop , Q , or ∆ ∆ ∆ ∆ ∆ L test? A. During Loop, Q , and ∆ L test, the tester is applying its own signal to the loop. The tester verifies there is no signal on the loop before running these tests. However , with a ...

  • ATS HILT 9000 - page 14

    13 HILT 9000 - Inductive Loop Tester Repair and Calibration To ensure that your instrument meets factory specifications, we recommend that it be retur ned to our factory at one-year intervals for calibration service. In addition to calibration of the test parameters, this service includes replacement of batteries and fir mware updates. Please conta ...

  • ATS HILT 9000 - page 15

    14 www.atsi-tester .com T echnical and Sales Assistance If you are experiencing any technical problems, or require any assistance with the proper operation or application of your tester , please call, fax, or e-mail our technical support staf f: ATSI 8157 US Route 50 • Athens, OH 45701 (740) 592-2984 (740) 594-2875 - Fax service@atsi-tester .com ...

  • ATS HILT 9000 - page 16

    15 HILT 9000 - Inductive Loop Tester -- This page left blank -- ...

  • ATS HILT 9000 - page 17

    16 www.atsi-tester .com Limited W arranty The HIL T 9000 (“Product”), distributed by Athens Technical Specialists, Inc. (ATSI), is warranted to the original purchaser (“Purchaser”) to be free of defects in materials and workmanship for a period of one year from the purchase date stated on the invoice. Within this period, in the event of a d ...

メーカー ATS カテゴリー Network Card

ATS HILT 9000のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- HILT 9000の取扱説明書
- ATSの製品カード
- パンフレット
- またはATS HILT 9000の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、ATS HILT 9000の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、ATS HILT 9000の取り付け説明書、サービスマニュアル、簡易説明書、またはATS HILT 9000のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、ATS HILT 9000の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

ATS HILT 9000デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがATS HILT 9000を使用するのを助ける技術的文書のことです。説明書は通常、全てのATS HILT 9000ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

ATSの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. ATS HILT 9000の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははATS HILT 9000の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。ATS HILT 9000に関してこのドキュメントで見つけることができる全てのヒントの目次
3. ATS HILT 9000デバイスの基本機能を使うにあたってのヒント。 ATS HILT 9000のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。ATS HILT 9000に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるATS HILT 9000のメーカー/サービスへの連絡先に関する情報。

ATS HILT 9000についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもATS HILT 9000の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがATS HILT 9000で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)