Manual de instrucciones ATS HILT 9000

17 de páginas 0.12 mb
Descargar

Pasar a la página of 17

Summary
  • ATS HILT 9000 - page 1

    HIL T 9000 Handheld Inductive Loop T ester User Manual July 2003 R=12.3 Ω Q=12.1 L=89.2µH 50KHz ATSI 8157 US Route 50 • Athens, OH 45701 (740) 592-2874 • Fax (740) 594-2875 sales@atsi-tester .com www.atsi-tester .com ...

  • ATS HILT 9000 - page 2

    1 HILT 9000 - Inductive Loop Tester T able of Contents Receiving Y our Shipment ......................................................... 2 Packaging ..... ........................................................................... 2 Description ............................................................................. 3 Overview of HIL T 9000 C ...

  • ATS HILT 9000 - page 3

    2 www.atsi-tester .com W a r nings These safety war ning are provided to ensure the safety of personnel and proper operation of the tester . • The tester must not be operated beyond its specified operating range. • Safety is the responsibility of the operator . Receiving your Shipment Upon receiving your shipment, be sure that the contents are ...

  • ATS HILT 9000 - page 4

    3 HILT 9000 - Inductive Loop Tester General Description The HILT -9000 is designed to measure characteristics of an inductive loop at dif ferent frequencies; measure working parameters of the loop system; as well as simulate the detector by measuring the change of inductance. The measurement modes can be easily switched by pressing corresponding bu ...

  • ATS HILT 9000 - page 5

    4 www.atsi-tester .com Overview of HIL T 9000 Contr ols 1. LOOP: Measures R DC , L, and Q . If Q >15, use Q push- button to obtain actual value. 2. Q : Measures high Q values (when Q is >15). 3. Used in SET FREQ mode to increase frequency by 1KHz. 4. Used in SET FREQ mode to decrease frequency by 1KHz. 5. POWER: Tur ns unit On/Off. 6. SET FRE ...

  • ATS HILT 9000 - page 6

    5 HILT 9000 - Inductive Loop Tester Function Controls Power Press the POWER push-button to tur n the tester on and off. The tester per for ms an initial self-test to verify that the inter nal circuit is working. After the self-test is complete, the tester shows the current battery level and the message: Ready: Select Function . If the battery is lo ...

  • ATS HILT 9000 - page 7

    6 www.atsi-tester .com The LOOP test can measure a maxi- mum Q of 15. If Q is greater than 15 the tester displays Q >15 . To measur e the actual value, press the Q button on the keypad to run a separate Q test. The default frequency at which the LOOP and Q tests run is 50 KHz. It can be changed to any value within the range from 20 KHz to 80 KHz ...

  • ATS HILT 9000 - page 8

    7 HILT 9000 - Inductive Loop Tester , , Set Frequency When the tester is powered, the test frequency is automatically set to 50 KHz. The frequency can be changed to any value between 20 KHz and 80 KHz with 1 KHz resolution. T o set a dif ferent fr equency press the SET FREQ push-button to view the fre- quency adjustment display as show in Figure 5. ...

  • ATS HILT 9000 - page 9

    8 www.atsi-tester .com If there is bad connection, the tester displays a message as shown in Figure 7. Make sure that the test leads are properly connected. If the leads are connected to the loop and the message is still present, it means that Q of the loop is too low to generate the oscilla- tion or the inductance is out of range. This can be veri ...

  • ATS HILT 9000 - page 10

    9 HILT 9000 - Inductive Loop Tester Function Controls Summary BUTTON DESC RIPTIO N COMMENTS LOOP Used to measure L, Q, and R DC of the loop. Q is measured up to 15. If Q> 15, use Q butt on to obtain th e actual v alue of Q The loop must be disconnected fro m the system to run th is test Q Used to m easure hig h Q values ( when Q is >15) The l ...

  • ATS HILT 9000 - page 11

    10 www.atsi-tester .com Overview of T raf fic Loop Detection Systems The inductive loop represents the most commonly used method to detect vehicles. The inductive loop is simply a coil of wires embedded into the pavement and can be characterized by several parameters, L (inductance), Q (quality factor), R (active resis- tance, measured using AC sig ...

  • ATS HILT 9000 - page 12

    11 HILT 9000 - Inductive Loop Tester To guarantee a reliable oscillation in the loop system the quality factor ( Q ) of the loop with the lead-in wires should be above some value, deter mined by the amplifiers inside the detector . Deterio- ration of the loop and lead-in wires reduces Q and eventually prevents the system from oscillating even with ...

  • ATS HILT 9000 - page 13

    12 www.atsi-tester .com Commonly Asked Questions Q . Why do I have to disconnect the detector from the loop before running a Loop , Q , or ∆ ∆ ∆ ∆ ∆ L test? A. During Loop, Q , and ∆ L test, the tester is applying its own signal to the loop. The tester verifies there is no signal on the loop before running these tests. However , with a ...

  • ATS HILT 9000 - page 14

    13 HILT 9000 - Inductive Loop Tester Repair and Calibration To ensure that your instrument meets factory specifications, we recommend that it be retur ned to our factory at one-year intervals for calibration service. In addition to calibration of the test parameters, this service includes replacement of batteries and fir mware updates. Please conta ...

  • ATS HILT 9000 - page 15

    14 www.atsi-tester .com T echnical and Sales Assistance If you are experiencing any technical problems, or require any assistance with the proper operation or application of your tester , please call, fax, or e-mail our technical support staf f: ATSI 8157 US Route 50 • Athens, OH 45701 (740) 592-2984 (740) 594-2875 - Fax service@atsi-tester .com ...

  • ATS HILT 9000 - page 16

    15 HILT 9000 - Inductive Loop Tester -- This page left blank -- ...

  • ATS HILT 9000 - page 17

    16 www.atsi-tester .com Limited W arranty The HIL T 9000 (“Product”), distributed by Athens Technical Specialists, Inc. (ATSI), is warranted to the original purchaser (“Purchaser”) to be free of defects in materials and workmanship for a period of one year from the purchase date stated on the invoice. Within this period, in the event of a d ...

Fabricante ATS Categoría Network Card

Los documentos del dispositivo ATS HILT 9000 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos ATS
- manuales de instrucciones HILT 9000
- hojas de producto ATS
- folletos informativos
- o etiquetas energéticas ATS HILT 9000
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones ATS HILT 9000.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje ATS HILT 9000, instrucciones de servicio, instrucciones cortas o instrucciones de usuario ATS HILT 9000. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto ATS HILT 9000.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo ATS HILT 9000, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar ATS HILT 9000. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de ATS HILT 9000.

El manual de instrucciones completo de ATS debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual ATS HILT 9000 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice ATS HILT 9000, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de ATS HILT 9000 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo ATS HILT 9000 - que deben facilitarnos los primeros pasos durante el uso de ATS HILT 9000
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con ATS HILT 9000
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de ATS HILT 9000 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de ATS HILT 9000?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con ATS HILT 9000, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con ATS HILT 9000 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)