Bedienungsanleitung Emerson 460

16 Seiten 0.79 mb
Download

Zur Seite of 16

Summary
  • Emerson 460 - page 1

    Infra struc ture Mana geme nt & Monit oring For Bu siness -Critic al C ontinuity™ Lieber t Liqui -tec t ® 460 Installa tion Manu al - Z one L eak Det ection Sens or ...

  • Emerson 460 - page 2

    ...

  • Emerson 460 - page 3

    i T ABLE OF CONTENTS I NTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 E XTERIOR D IMENSIONS AND M OUNTING D ET AILS . . . . . . . . . . . 1 P LACEMENT ON S UBFLOOR U NDER C OOLI NG S UPPORT E QUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 P OWER W IRIN G . . . . . . . . ...

  • Emerson 460 - page 4

    ii ...

  • Emerson 460 - page 5

    1 Introduction Liebert Liqui-tect ® Leak Detection Sensors install quickly an d work simply for reliable detection of condu ctive aqueous fluid leaks. The Liqui-tect 460 Sensor provides zo ne protecti on using the easy-to- install and quick-drying Liebert leak detection cable. LEDs located on the top cover of the module provid e visual indication. ...

  • Emerson 460 - page 6

    2 Placement on Subfloor Under Cool ing Support Equipment (Other applications such as long perimeter walls can be monitored) As shown above , the Liqui-tect 460 (LT460) may be placed on a sub- floor, where it is connected to the leak detection cable t hat surrounds the leak detection zone —the area directly beneath the unit being protected or othe ...

  • Emerson 460 - page 7

    3 Power Wiring The LT460 is rated for 24 VAC, 50/60 Hz and 0.12 amp. Figure 1 24V from Liebert environment al units to L T460 Figure 2 24V from transformer to L T460 Power Wi ring 24V from Li ebe rt En viro nmenta l Uni t to LT46 0 Lieber t Deluxe Sys /3, Challeng er, Him od or MM2 (8 Ton) TB1 T5 (24V) G5 (Ground) LT460 TB1 TB1- 1 TB1- 2 24V from T ...

  • Emerson 460 - page 8

    4 Wiring to Auxiliary Alarm Panels The LT460 has two Form-C dry contac t alarm output contacts (TB2 & TB3). Each contact is rated for 24 VAC at 3 amp. Figure 3 L T460 to Liebert environment al unit s Figure 4 L T460 to Liebert cont act monitor p anel Liebert Deluxe Sys /3, Challenger, Him od or MM2 (8 To n) 24 (24V) 51 LT460 TB2 TB2-2 (C) TB2- ...

  • Emerson 460 - page 9

    5 Configuration Switch Settings A four-position DIP switch is used to select two alarm (filter) delays and three mutually exclusive alarm modes. The switches are located next to the wiring termination blocks. Leak Detect Filter Delay (SS1) SS1 selects the leak detect filter delay , the interval for which a leak condition must b e continuously detec ...

  • Emerson 460 - page 10

    6 Alarm Retest Delay (SS3) SS3 selects the alarm retest delay , the setting in which an alarm is latched and reteste d every hour. OFF = Non-latching (default) ON = Latching-retest each hour The factory default is OFF = Non-latching. If SS3 = ON and a leak is detected, the alarm conditi on is latche d, the sensor goes into a “sleep” mode and po ...

  • Emerson 460 - page 11

    7 LED Operation System Normal (Green): • ON contin uously whe n power is applied to sensor. Alarm Pending (Y ellow): • ON continuously duri ng leak detect filter delay and cable fault delay. • FLASHING (with Leak Detected LED) to indicate cable fault cond ition. Leak Detected (Red): • FLASHING to indicate leak detected alarm. • FLASHING ( ...

  • Emerson 460 - page 12

    8 Inst allation of Leak De tection System Cable 1. Attach the leak detection cable to the LT460 module. 2. Activate module and test detect ion cable. (Touch detection cable with a clean moist cloth or paper towel. ) Dry detection cable to remove the alarm condition. (A hair dryer can be used to speed up the drying.) Note: Do not try to saturate the ...

  • Emerson 460 - page 13

    9 4. The installation o f th e hold-down clips should be in pairs according to Figure 5 with the follow ing considerations: Figure 5 Inst a llation of hold-down clip s in pairs a. On e pair every 6 to 8 feet in stra ight patterns (see Figure 6 ). b. On e pair every 3 to 4 feet in circular patterns (see Figure 7 ). c. One pair at the beginni ng an d ...

  • Emerson 460 - page 14

    10 Leak Detection Kit In st allation Scenarios Scenarios Upflow Unit Detection around entire unit Up flow Unit Detection on sides and in front of unit Downflow Unit Detection around entire unit Downflow Unit Detection on sides and in front of unit Distance from unit Distance: In back On sides In front 2 ft 2 ft 2 ft No cable behind 2 ft 2 ft 1 ft 1 ...

  • Emerson 460 - page 15

    ...

  • Emerson 460 - page 16

    Ensuring The High A vaila bility Of Mission-Critic al Dat a And App lic ations. While every precaution has been tak en to ensure the accuracy and comple teness of this lite rature, Lie bert Corporation assumes no responsibility and disclaims all liability for damages resulting from u se of this inform ation or for any e rrors or omissions . © 2010 ...

Produzent Emerson Kategorie Home Security System

Dokumente, die wir vom Produzenten des Geräts Emerson 460 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Emerson
- Bedienungsanleitungen 460
- Produktkarten Emerson
- Informationsbroschüren
- oder Energieetiketten Emerson 460
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Emerson 460.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Emerson 460, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Emerson 460. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Emerson 460 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Emerson 460, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Emerson 460 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Emerson 460 verständlich ist.

Eine gänzliche Bedienungsanleitung von Emerson sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Emerson 460 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Emerson 460 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Emerson 460, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Emerson 460 - die uns die ersten Schritte während der Nutzung von Emerson 460 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Emerson 460 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Emerson 460 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Emerson 460?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Emerson 460 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Emerson 460 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen