Manual de instrucciones Emerson 460

16 de páginas 0.79 mb
Descargar

Pasar a la página of 16

Summary
  • Emerson 460 - page 1

    Infra struc ture Mana geme nt & Monit oring For Bu siness -Critic al C ontinuity™ Lieber t Liqui -tec t ® 460 Installa tion Manu al - Z one L eak Det ection Sens or ...

  • Emerson 460 - page 2

    ...

  • Emerson 460 - page 3

    i T ABLE OF CONTENTS I NTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 E XTERIOR D IMENSIONS AND M OUNTING D ET AILS . . . . . . . . . . . 1 P LACEMENT ON S UBFLOOR U NDER C OOLI NG S UPPORT E QUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 P OWER W IRIN G . . . . . . . . ...

  • Emerson 460 - page 4

    ii ...

  • Emerson 460 - page 5

    1 Introduction Liebert Liqui-tect ® Leak Detection Sensors install quickly an d work simply for reliable detection of condu ctive aqueous fluid leaks. The Liqui-tect 460 Sensor provides zo ne protecti on using the easy-to- install and quick-drying Liebert leak detection cable. LEDs located on the top cover of the module provid e visual indication. ...

  • Emerson 460 - page 6

    2 Placement on Subfloor Under Cool ing Support Equipment (Other applications such as long perimeter walls can be monitored) As shown above , the Liqui-tect 460 (LT460) may be placed on a sub- floor, where it is connected to the leak detection cable t hat surrounds the leak detection zone —the area directly beneath the unit being protected or othe ...

  • Emerson 460 - page 7

    3 Power Wiring The LT460 is rated for 24 VAC, 50/60 Hz and 0.12 amp. Figure 1 24V from Liebert environment al units to L T460 Figure 2 24V from transformer to L T460 Power Wi ring 24V from Li ebe rt En viro nmenta l Uni t to LT46 0 Lieber t Deluxe Sys /3, Challeng er, Him od or MM2 (8 Ton) TB1 T5 (24V) G5 (Ground) LT460 TB1 TB1- 1 TB1- 2 24V from T ...

  • Emerson 460 - page 8

    4 Wiring to Auxiliary Alarm Panels The LT460 has two Form-C dry contac t alarm output contacts (TB2 & TB3). Each contact is rated for 24 VAC at 3 amp. Figure 3 L T460 to Liebert environment al unit s Figure 4 L T460 to Liebert cont act monitor p anel Liebert Deluxe Sys /3, Challenger, Him od or MM2 (8 To n) 24 (24V) 51 LT460 TB2 TB2-2 (C) TB2- ...

  • Emerson 460 - page 9

    5 Configuration Switch Settings A four-position DIP switch is used to select two alarm (filter) delays and three mutually exclusive alarm modes. The switches are located next to the wiring termination blocks. Leak Detect Filter Delay (SS1) SS1 selects the leak detect filter delay , the interval for which a leak condition must b e continuously detec ...

  • Emerson 460 - page 10

    6 Alarm Retest Delay (SS3) SS3 selects the alarm retest delay , the setting in which an alarm is latched and reteste d every hour. OFF = Non-latching (default) ON = Latching-retest each hour The factory default is OFF = Non-latching. If SS3 = ON and a leak is detected, the alarm conditi on is latche d, the sensor goes into a “sleep” mode and po ...

  • Emerson 460 - page 11

    7 LED Operation System Normal (Green): • ON contin uously whe n power is applied to sensor. Alarm Pending (Y ellow): • ON continuously duri ng leak detect filter delay and cable fault delay. • FLASHING (with Leak Detected LED) to indicate cable fault cond ition. Leak Detected (Red): • FLASHING to indicate leak detected alarm. • FLASHING ( ...

  • Emerson 460 - page 12

    8 Inst allation of Leak De tection System Cable 1. Attach the leak detection cable to the LT460 module. 2. Activate module and test detect ion cable. (Touch detection cable with a clean moist cloth or paper towel. ) Dry detection cable to remove the alarm condition. (A hair dryer can be used to speed up the drying.) Note: Do not try to saturate the ...

  • Emerson 460 - page 13

    9 4. The installation o f th e hold-down clips should be in pairs according to Figure 5 with the follow ing considerations: Figure 5 Inst a llation of hold-down clip s in pairs a. On e pair every 6 to 8 feet in stra ight patterns (see Figure 6 ). b. On e pair every 3 to 4 feet in circular patterns (see Figure 7 ). c. One pair at the beginni ng an d ...

  • Emerson 460 - page 14

    10 Leak Detection Kit In st allation Scenarios Scenarios Upflow Unit Detection around entire unit Up flow Unit Detection on sides and in front of unit Downflow Unit Detection around entire unit Downflow Unit Detection on sides and in front of unit Distance from unit Distance: In back On sides In front 2 ft 2 ft 2 ft No cable behind 2 ft 2 ft 1 ft 1 ...

  • Emerson 460 - page 15

    ...

  • Emerson 460 - page 16

    Ensuring The High A vaila bility Of Mission-Critic al Dat a And App lic ations. While every precaution has been tak en to ensure the accuracy and comple teness of this lite rature, Lie bert Corporation assumes no responsibility and disclaims all liability for damages resulting from u se of this inform ation or for any e rrors or omissions . © 2010 ...

Fabricante Emerson Categoría Home Security System

Los documentos del dispositivo Emerson 460 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Emerson
- manuales de instrucciones 460
- hojas de producto Emerson
- folletos informativos
- o etiquetas energéticas Emerson 460
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Emerson 460.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Emerson 460, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Emerson 460. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Emerson 460.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Emerson 460, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Emerson 460. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Emerson 460.

El manual de instrucciones completo de Emerson debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Emerson 460 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Emerson 460, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Emerson 460 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Emerson 460 - que deben facilitarnos los primeros pasos durante el uso de Emerson 460
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Emerson 460
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Emerson 460 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Emerson 460?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Emerson 460, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Emerson 460 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)