Summary
  • Emerson 460 - page 1

    Infra struc ture Mana geme nt & Monit oring For Bu siness -Critic al C ontinuity™ Lieber t Liqui -tec t ® 460 Installa tion Manu al - Z one L eak Det ection Sens or ...

  • Emerson 460 - page 2

    ...

  • Emerson 460 - page 3

    i T ABLE OF CONTENTS I NTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 E XTERIOR D IMENSIONS AND M OUNTING D ET AILS . . . . . . . . . . . 1 P LACEMENT ON S UBFLOOR U NDER C OOLI NG S UPPORT E QUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 P OWER W IRIN G . . . . . . . . ...

  • Emerson 460 - page 4

    ii ...

  • Emerson 460 - page 5

    1 Introduction Liebert Liqui-tect ® Leak Detection Sensors install quickly an d work simply for reliable detection of condu ctive aqueous fluid leaks. The Liqui-tect 460 Sensor provides zo ne protecti on using the easy-to- install and quick-drying Liebert leak detection cable. LEDs located on the top cover of the module provid e visual indication. ...

  • Emerson 460 - page 6

    2 Placement on Subfloor Under Cool ing Support Equipment (Other applications such as long perimeter walls can be monitored) As shown above , the Liqui-tect 460 (LT460) may be placed on a sub- floor, where it is connected to the leak detection cable t hat surrounds the leak detection zone —the area directly beneath the unit being protected or othe ...

  • Emerson 460 - page 7

    3 Power Wiring The LT460 is rated for 24 VAC, 50/60 Hz and 0.12 amp. Figure 1 24V from Liebert environment al units to L T460 Figure 2 24V from transformer to L T460 Power Wi ring 24V from Li ebe rt En viro nmenta l Uni t to LT46 0 Lieber t Deluxe Sys /3, Challeng er, Him od or MM2 (8 Ton) TB1 T5 (24V) G5 (Ground) LT460 TB1 TB1- 1 TB1- 2 24V from T ...

  • Emerson 460 - page 8

    4 Wiring to Auxiliary Alarm Panels The LT460 has two Form-C dry contac t alarm output contacts (TB2 & TB3). Each contact is rated for 24 VAC at 3 amp. Figure 3 L T460 to Liebert environment al unit s Figure 4 L T460 to Liebert cont act monitor p anel Liebert Deluxe Sys /3, Challenger, Him od or MM2 (8 To n) 24 (24V) 51 LT460 TB2 TB2-2 (C) TB2- ...

  • Emerson 460 - page 9

    5 Configuration Switch Settings A four-position DIP switch is used to select two alarm (filter) delays and three mutually exclusive alarm modes. The switches are located next to the wiring termination blocks. Leak Detect Filter Delay (SS1) SS1 selects the leak detect filter delay , the interval for which a leak condition must b e continuously detec ...

  • Emerson 460 - page 10

    6 Alarm Retest Delay (SS3) SS3 selects the alarm retest delay , the setting in which an alarm is latched and reteste d every hour. OFF = Non-latching (default) ON = Latching-retest each hour The factory default is OFF = Non-latching. If SS3 = ON and a leak is detected, the alarm conditi on is latche d, the sensor goes into a “sleep” mode and po ...

  • Emerson 460 - page 11

    7 LED Operation System Normal (Green): • ON contin uously whe n power is applied to sensor. Alarm Pending (Y ellow): • ON continuously duri ng leak detect filter delay and cable fault delay. • FLASHING (with Leak Detected LED) to indicate cable fault cond ition. Leak Detected (Red): • FLASHING to indicate leak detected alarm. • FLASHING ( ...

  • Emerson 460 - page 12

    8 Inst allation of Leak De tection System Cable 1. Attach the leak detection cable to the LT460 module. 2. Activate module and test detect ion cable. (Touch detection cable with a clean moist cloth or paper towel. ) Dry detection cable to remove the alarm condition. (A hair dryer can be used to speed up the drying.) Note: Do not try to saturate the ...

  • Emerson 460 - page 13

    9 4. The installation o f th e hold-down clips should be in pairs according to Figure 5 with the follow ing considerations: Figure 5 Inst a llation of hold-down clip s in pairs a. On e pair every 6 to 8 feet in stra ight patterns (see Figure 6 ). b. On e pair every 3 to 4 feet in circular patterns (see Figure 7 ). c. One pair at the beginni ng an d ...

  • Emerson 460 - page 14

    10 Leak Detection Kit In st allation Scenarios Scenarios Upflow Unit Detection around entire unit Up flow Unit Detection on sides and in front of unit Downflow Unit Detection around entire unit Downflow Unit Detection on sides and in front of unit Distance from unit Distance: In back On sides In front 2 ft 2 ft 2 ft No cable behind 2 ft 2 ft 1 ft 1 ...

  • Emerson 460 - page 15

    ...

  • Emerson 460 - page 16

    Ensuring The High A vaila bility Of Mission-Critic al Dat a And App lic ations. While every precaution has been tak en to ensure the accuracy and comple teness of this lite rature, Lie bert Corporation assumes no responsibility and disclaims all liability for damages resulting from u se of this inform ation or for any e rrors or omissions . © 2010 ...

Fabricant Emerson Catégorie Home Security System

Les documents que nous recevons du fabricant de l'appareilEmerson 460 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Emerson
- manuels d’utilisations 460
- fiches produit Emerson
- dépliants
- ou étiquettes-énergie Emerson 460
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Emerson 460.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Emerson 460, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Emerson 460. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Emerson 460.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Emerson 460, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Emerson 460 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Emerson 460.

Le manuel d’utilisation complet Emerson, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Emerson 460 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Emerson 460, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lEmerson 460 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Emerson 460 - qui devraient nous aider dans les premières étapes lors de l'utilisation Emerson 460
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Emerson 460
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Emerson 460 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Emerson 460?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Emerson 460, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Emerson 460 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)