    Infra struc ture Mana geme nt & Monit oring For Bu siness -Critic al C ontinuity™ Lieber t Liqui -tec t ® 460 Installa tion Manu al - Z one L eak Det ection Sens or ...

  • Emerson 460 - page 2

    ...

  • Emerson 460 - page 3

    i T ABLE OF CONTENTS I NTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 E XTERIOR D IMENSIONS AND M OUNTING D ET AILS . . . . . . . . . . . 1 P LACEMENT ON S UBFLOOR U NDER C OOLI NG S UPPORT E QUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 P OWER W IRIN G . . . . . . . . ...

  • Emerson 460 - page 4

    ii ...

  • Emerson 460 - page 5

    1 Introduction Liebert Liqui-tect ® Leak Detection Sensors install quickly an d work simply for reliable detection of condu ctive aqueous fluid leaks. The Liqui-tect 460 Sensor provides zo ne protecti on using the easy-to- install and quick-drying Liebert leak detection cable. LEDs located on the top cover of the module provid e visual indication. ...

  • Emerson 460 - page 6

    2 Placement on Subfloor Under Cool ing Support Equipment (Other applications such as long perimeter walls can be monitored) As shown above , the Liqui-tect 460 (LT460) may be placed on a sub- floor, where it is connected to the leak detection cable t hat surrounds the leak detection zone —the area directly beneath the unit being protected or othe ...

  • Emerson 460 - page 7

    3 Power Wiring The LT460 is rated for 24 VAC, 50/60 Hz and 0.12 amp. Figure 1 24V from Liebert environment al units to L T460 Figure 2 24V from transformer to L T460 Power Wi ring 24V from Li ebe rt En viro nmenta l Uni t to LT46 0 Lieber t Deluxe Sys /3, Challeng er, Him od or MM2 (8 Ton) TB1 T5 (24V) G5 (Ground) LT460 TB1 TB1- 1 TB1- 2 24V from T ...

  • Emerson 460 - page 8

    4 Wiring to Auxiliary Alarm Panels The LT460 has two Form-C dry contac t alarm output contacts (TB2 & TB3). Each contact is rated for 24 VAC at 3 amp. Figure 3 L T460 to Liebert environment al unit s Figure 4 L T460 to Liebert cont act monitor p anel Liebert Deluxe Sys /3, Challenger, Him od or MM2 (8 To n) 24 (24V) 51 LT460 TB2 TB2-2 (C) TB2- ...

  • Emerson 460 - page 9

    5 Configuration Switch Settings A four-position DIP switch is used to select two alarm (filter) delays and three mutually exclusive alarm modes. The switches are located next to the wiring termination blocks. Leak Detect Filter Delay (SS1) SS1 selects the leak detect filter delay , the interval for which a leak condition must b e continuously detec ...

  • Emerson 460 - page 10

    6 Alarm Retest Delay (SS3) SS3 selects the alarm retest delay , the setting in which an alarm is latched and reteste d every hour. OFF = Non-latching (default) ON = Latching-retest each hour The factory default is OFF = Non-latching. If SS3 = ON and a leak is detected, the alarm conditi on is latche d, the sensor goes into a “sleep” mode and po ...

  • Emerson 460 - page 11

    7 LED Operation System Normal (Green): • ON contin uously whe n power is applied to sensor. Alarm Pending (Y ellow): • ON continuously duri ng leak detect filter delay and cable fault delay. • FLASHING (with Leak Detected LED) to indicate cable fault cond ition. Leak Detected (Red): • FLASHING to indicate leak detected alarm. • FLASHING ( ...

  • Emerson 460 - page 12

    8 Inst allation of Leak De tection System Cable 1. Attach the leak detection cable to the LT460 module. 2. Activate module and test detect ion cable. (Touch detection cable with a clean moist cloth or paper towel. ) Dry detection cable to remove the alarm condition. (A hair dryer can be used to speed up the drying.) Note: Do not try to saturate the ...

  • Emerson 460 - page 13

    9 4. The installation o f th e hold-down clips should be in pairs according to Figure 5 with the follow ing considerations: Figure 5 Inst a llation of hold-down clip s in pairs a. On e pair every 6 to 8 feet in stra ight patterns (see Figure 6 ). b. On e pair every 3 to 4 feet in circular patterns (see Figure 7 ). c. One pair at the beginni ng an d ...

  • Emerson 460 - page 14

    10 Leak Detection Kit In st allation Scenarios Scenarios Upflow Unit Detection around entire unit Up flow Unit Detection on sides and in front of unit Downflow Unit Detection around entire unit Downflow Unit Detection on sides and in front of unit Distance from unit Distance: In back On sides In front 2 ft 2 ft 2 ft No cable behind 2 ft 2 ft 1 ft 1 ...

  • Emerson 460 - page 15

    ...

  • Emerson 460 - page 16

    Ensuring The High A vaila bility Of Mission-Critic al Dat a And App lic ations. While every precaution has been tak en to ensure the accuracy and comple teness of this lite rature, Lie bert Corporation assumes no responsibility and disclaims all liability for damages resulting from u se of this inform ation or for any e rrors or omissions . © 2010 ...

Fabbricante Emerson Categoria Home Security System

I documenti che otteniamo dal fabbricante del dispositivoEmerson 460 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Emerson
- manuali per l’uso 460
- schede prodotto Emerson
- opuscoli
- o etichette energetiche Emerson 460
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Emerson 460.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Emerson 460, manuali di manutenzione, brevi manuali o manuali utente Emerson 460. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Emerson 460.

Manuali per l’uso simili

Manuale completo del dispositivo Emerson 460, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Emerson 460 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Emerson 460.

Il manuale per l’uso completo Emerson, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Emerson 460 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Emerson 460, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Emerson 460 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Emerson 460 - che ci dovrebbe aiutare nei primi passi durante l'uso Emerson 460
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Emerson 460
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Emerson 460 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Emerson 460?

Utilizza il modulo sottostante

Se non hai risolto il problema con Emerson 460 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Emerson 460 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)