  • Bryant 576b - page 1

    Cancels : II 569C-7 2-4 II 569C-72 -5 8/15/00 IMPORT ANT — READ BEFORE INST ALLING 1. Read an d become fam iliar w ith these install ation instruc tions b efore insta lling t his unit (Fig . 1). 2. Be sure the i nst alla tion conf orms t o all a ppl icab le local a nd na tion al code s. 3. These instru ctions co ntain i mportant i nforma tion fo ...

  • Bryant 576b - page 2

    — 2 — INST ALLA TION NO TE: When inst alli ng any a cces sory i tem, see the m anuf ac- turer’s installation instructions packaged with the accessory . A quali f ie d age nc y must us e f ac t ory - au th orize d ki ts or acc e s- sories when mo dify ing this unit. The 569 C072, 090, and 1 20 uni ts use hermet ic compr essors . The 576B 09 0, ...

  • Bryant 576b - page 3

    — 3 — T a ble 1 — Ph ysical Data LEGEND *Unit is factory supplied w ith holding charge only . †T y pical operating charge with 25 f t of interconnec ting piping. **Storage capacity of condenser coil with coil 80% fu ll of liquid R-22 at 124 F . NO TE: Unit 576B120 has one step of unloading. Full load is 100% of capacity , and one step of un ...

  • Bryant 576b - page 4

    — 4 — DIMENSIONS (f t- i n. ) UNIT A B C D E F With Alum inum Coils (Standar d) 569C072 1-6 1 / 2 1-2 3 / 4 —1 - 2 1 / 4 1-4 5 / 16 2-9 5 / 16 569C090 1-8 1-6 1 / 2 2-9 13 / 16 1- 3 2- 5 / 16 3-5 7 / 16 569C120 1-9 1-8 2-0 1- 3 2- 5 / 16 3-5 7 / 16 576B090 1-6 1-4 3 / 4 2-9 13 / 16 1- 3 2- 5 / 16 3-5 7 / 16 576B102 1-7 1-5 2-9 13 / 16 1-3 2- ...

  • Bryant 576b - page 5

    — 5 — B. Filter Drier and Moistu re Indica tor The fil ter d rier i s factor y ins talled. Mois ture in dicat or i s a field-ins talled acc essory and s hould be instal led just aft er liqui d line s hutof f valv e at th e evapo rat or coil . Do no t use a receiver . A receiver is not supplied with the unit and s hould not be us ed. NO TE: Unit ...

  • Bryant 576b - page 6

    — 6 — the current within 10%. Use the formula shown in T able 4, Note 2, to de termine the percent vo ltage imbal ance. Ope rat ion o n impr oper line volta ge or exces sive ph ase im bala nce cons tit utes abu se a nd may cau se dama ge t o elec trica l co mponen ts. Su ch op era- tion would invalidate any appli cable w arranty . 4. In sula te ...

  • Bryant 576b - page 7

    — 7 — T ab le 4 — Ele ctrical Data LEGEND NO TES: 1. In compliance with NEC requirements f or multimotor and combina- tion load equipment (refer to NEC Ar ticles 430 and 440), the over- current protective de vice f or t he unit shall be fuse or HA CR breaker . The Canadian units m a y be fuse or circuit breaker . 2. Unbalanced 3-Pha se Suppl ...

  • Bryant 576b - page 8

    — 8 — VI. A CCESSOR Y INST ALLA TION At t his ti me a ny requi red access ories shoul d be in stalled on the un it. Refer to T a ble 5 for a vailabl e ac cessorie s . Con trol wiri ng informat ion is provid ed in the unit w iri ng book. T able 5 — Accesso ry List PRE-ST ART -UP Procee d as follows to i nspect and pr epare the unit for initial ...

  • Bryant 576b - page 9

    — 9 — ST ART -UP I. ST ART -UP AND ADJUSTMENTS A. Chec king Co oling Contr ol Operation Start an d check the uni t for proper co olin g contro l opera tion as fol lo w s: 1. Plac e room ther mostat SYST EM swi tch i n OFF posi- tion. Obs erve tha t blow er moto r starts w hen F AN switch is placed in ON position and s huts down when F AN switc ...

  • Bryant 576b - page 10

    — 10 — SER VICE I. CLEANING Inspe ct unit interi or at t he beginn ing of each co oling se ason and as ope ratin g condition s require . A. Condenser Coil Inspect co il monthly . Clean conden ser coil an nually , or as requir ed by loca tion and ou tdoor-air conditions. Clean coil as fo llows: 1. Turn off unit power and tag disconnect. 2. Remov ...

  • Bryant 576b - page 11

    — 11 — IV . CAP A CITY CONTROL (576B12 0 Only) A suction pressu re-actuated u nloader con trols 2 cy linders and provides capacity control. Unloa ders are fa ctory set (see T able 1) , but may b e field adjus ted: A. Contr ol Set Po int The c ontro l se t po int ( cylin der l oad p oint ) is adju stab le from 0 to 85 psig . T o adjust, turn con ...

  • Bryant 576b - page 12

    — 12 — VIII. REFRIGERANT SER VICE POR TS Eac h unit has 3 s ervic e port s: on e on th e suc tion li ne , on e on the liq uid line, and on e on the comp resso r discha rge line. Be sure caps on the po rts are tight. IX. H IGH FL O W V AL V ES Located on the compres sor hot gas and suction tubes are High Flow V alves . Large black plastic c aps ...

  • Bryant 576b - page 13

    — 13 — TROUBLESHOO TING GUIDE NO TE: See Fig. 15 and 16 for component arrangements. SYMPT OM CA USE REMED Y Compressor does not run — Contactor open P ower off . Restore power . Fuses blown. Replace with correct fuses after finding cause and correcting. T ransformer open/shor ted. Replace transformer if primar y windings are receiving power a ...

  • Bryant 576b - page 14

    Copyright 20 00 Br yant H eating & Coo ling Sy stems 801 CA T ALOG NO. 5356-90 3 LEGEND FOR FIG. 15 AND 16 C— Contactor , Compressor CAP — Capacitor CB — Circuit Breaker CH — Crankcase Heater CLO — Compressor Lockout COMP — Compres sor Moto r CO TP — Compressor T emperature Protection EQUIP — Equipment GND — Ground HPS — Hig ...

  • Bryant 576b - page 15

    CL-1 ST ART -UP CHECKLIST I. PRELIMINAR Y INFORMA TION OUTDO OR: MODE L NO . ____________ ______ _____ _________ __ SERIAL NO . ___ _____ _________ _____ ______ ________ INDOOR: AI R HANDL ER MAN UF ACTUR ER _____ _________ ______________ _____ ______ ________ ______ _____ ___ MODE L NO . _____________ ______ _____ _________ __ SERIAL NO . ___ ____ ...

  • Bryant 576b - page 16

    Copyright 20 00 Br yant H eating & Cool ing Sy stems 801 CL-2 CA T ALOG NO . 5356-903 CUT ALONG DOT TED LINE CUT ALONG DO TTED LINE III. ST ART -UP CHECK EV APORA T OR-F AN SPEED AND RECORD . _______ CHECK CONDENSER-F AN SPEED AND RECORD . _______ AFTER A T LEAST 15 MINUTES R UNNING TIME, RECORD THE FOLLO WING MEASUREMENTS: COMP RESSOR AMPS (L ...

Produzent Bryant Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts Bryant 576b erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Bryant
- Bedienungsanleitungen 576b
- Produktkarten Bryant
- Informationsbroschüren
- oder Energieetiketten Bryant 576b
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Bryant 576b.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Bryant 576b, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Bryant 576b. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Bryant 576b ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Bryant 576b, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Bryant 576b hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Bryant 576b verständlich ist.

Eine gänzliche Bedienungsanleitung von Bryant sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Bryant 576b bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Bryant 576b befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Bryant 576b, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Bryant 576b - die uns die ersten Schritte während der Nutzung von Bryant 576b erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Bryant 576b hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Bryant 576b im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Bryant 576b?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Bryant 576b nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Bryant 576b hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)