  • Bryant 576b - page 1

    Cancels : II 569C-7 2-4 II 569C-72 -5 8/15/00 IMPORT ANT — READ BEFORE INST ALLING 1. Read an d become fam iliar w ith these install ation instruc tions b efore insta lling t his unit (Fig . 1). 2. Be sure the i nst alla tion conf orms t o all a ppl icab le local a nd na tion al code s. 3. These instru ctions co ntain i mportant i nforma tion fo ...

  • Bryant 576b - page 2

    — 2 — INST ALLA TION NO TE: When inst alli ng any a cces sory i tem, see the m anuf ac- turer’s installation instructions packaged with the accessory . A quali f ie d age nc y must us e f ac t ory - au th orize d ki ts or acc e s- sories when mo dify ing this unit. The 569 C072, 090, and 1 20 uni ts use hermet ic compr essors . The 576B 09 0, ...

  • Bryant 576b - page 3

    — 3 — T a ble 1 — Ph ysical Data LEGEND *Unit is factory supplied w ith holding charge only . †T y pical operating charge with 25 f t of interconnec ting piping. **Storage capacity of condenser coil with coil 80% fu ll of liquid R-22 at 124 F . NO TE: Unit 576B120 has one step of unloading. Full load is 100% of capacity , and one step of un ...

  • Bryant 576b - page 4

    — 4 — DIMENSIONS (f t- i n. ) UNIT A B C D E F With Alum inum Coils (Standar d) 569C072 1-6 1 / 2 1-2 3 / 4 —1 - 2 1 / 4 1-4 5 / 16 2-9 5 / 16 569C090 1-8 1-6 1 / 2 2-9 13 / 16 1- 3 2- 5 / 16 3-5 7 / 16 569C120 1-9 1-8 2-0 1- 3 2- 5 / 16 3-5 7 / 16 576B090 1-6 1-4 3 / 4 2-9 13 / 16 1- 3 2- 5 / 16 3-5 7 / 16 576B102 1-7 1-5 2-9 13 / 16 1-3 2- ...

  • Bryant 576b - page 5

    — 5 — B. Filter Drier and Moistu re Indica tor The fil ter d rier i s factor y ins talled. Mois ture in dicat or i s a field-ins talled acc essory and s hould be instal led just aft er liqui d line s hutof f valv e at th e evapo rat or coil . Do no t use a receiver . A receiver is not supplied with the unit and s hould not be us ed. NO TE: Unit ...

  • Bryant 576b - page 6

    — 6 — the current within 10%. Use the formula shown in T able 4, Note 2, to de termine the percent vo ltage imbal ance. Ope rat ion o n impr oper line volta ge or exces sive ph ase im bala nce cons tit utes abu se a nd may cau se dama ge t o elec trica l co mponen ts. Su ch op era- tion would invalidate any appli cable w arranty . 4. In sula te ...

  • Bryant 576b - page 7

    — 7 — T ab le 4 — Ele ctrical Data LEGEND NO TES: 1. In compliance with NEC requirements f or multimotor and combina- tion load equipment (refer to NEC Ar ticles 430 and 440), the over- current protective de vice f or t he unit shall be fuse or HA CR breaker . The Canadian units m a y be fuse or circuit breaker . 2. Unbalanced 3-Pha se Suppl ...

  • Bryant 576b - page 8

    — 8 — VI. A CCESSOR Y INST ALLA TION At t his ti me a ny requi red access ories shoul d be in stalled on the un it. Refer to T a ble 5 for a vailabl e ac cessorie s . Con trol wiri ng informat ion is provid ed in the unit w iri ng book. T able 5 — Accesso ry List PRE-ST ART -UP Procee d as follows to i nspect and pr epare the unit for initial ...

  • Bryant 576b - page 9

    — 9 — ST ART -UP I. ST ART -UP AND ADJUSTMENTS A. Chec king Co oling Contr ol Operation Start an d check the uni t for proper co olin g contro l opera tion as fol lo w s: 1. Plac e room ther mostat SYST EM swi tch i n OFF posi- tion. Obs erve tha t blow er moto r starts w hen F AN switch is placed in ON position and s huts down when F AN switc ...

  • Bryant 576b - page 10

    — 10 — SER VICE I. CLEANING Inspe ct unit interi or at t he beginn ing of each co oling se ason and as ope ratin g condition s require . A. Condenser Coil Inspect co il monthly . Clean conden ser coil an nually , or as requir ed by loca tion and ou tdoor-air conditions. Clean coil as fo llows: 1. Turn off unit power and tag disconnect. 2. Remov ...

  • Bryant 576b - page 11

    — 11 — IV . CAP A CITY CONTROL (576B12 0 Only) A suction pressu re-actuated u nloader con trols 2 cy linders and provides capacity control. Unloa ders are fa ctory set (see T able 1) , but may b e field adjus ted: A. Contr ol Set Po int The c ontro l se t po int ( cylin der l oad p oint ) is adju stab le from 0 to 85 psig . T o adjust, turn con ...

  • Bryant 576b - page 12

    — 12 — VIII. REFRIGERANT SER VICE POR TS Eac h unit has 3 s ervic e port s: on e on th e suc tion li ne , on e on the liq uid line, and on e on the comp resso r discha rge line. Be sure caps on the po rts are tight. IX. H IGH FL O W V AL V ES Located on the compres sor hot gas and suction tubes are High Flow V alves . Large black plastic c aps ...

  • Bryant 576b - page 13

    — 13 — TROUBLESHOO TING GUIDE NO TE: See Fig. 15 and 16 for component arrangements. SYMPT OM CA USE REMED Y Compressor does not run — Contactor open P ower off . Restore power . Fuses blown. Replace with correct fuses after finding cause and correcting. T ransformer open/shor ted. Replace transformer if primar y windings are receiving power a ...

  • Bryant 576b - page 14

    Copyright 20 00 Br yant H eating & Coo ling Sy stems 801 CA T ALOG NO. 5356-90 3 LEGEND FOR FIG. 15 AND 16 C— Contactor , Compressor CAP — Capacitor CB — Circuit Breaker CH — Crankcase Heater CLO — Compressor Lockout COMP — Compres sor Moto r CO TP — Compressor T emperature Protection EQUIP — Equipment GND — Ground HPS — Hig ...

  • Bryant 576b - page 15

    CL-1 ST ART -UP CHECKLIST I. PRELIMINAR Y INFORMA TION OUTDO OR: MODE L NO . ____________ ______ _____ _________ __ SERIAL NO . ___ _____ _________ _____ ______ ________ INDOOR: AI R HANDL ER MAN UF ACTUR ER _____ _________ ______________ _____ ______ ________ ______ _____ ___ MODE L NO . _____________ ______ _____ _________ __ SERIAL NO . ___ ____ ...

  • Bryant 576b - page 16

    Copyright 20 00 Br yant H eating & Cool ing Sy stems 801 CL-2 CA T ALOG NO . 5356-903 CUT ALONG DOT TED LINE CUT ALONG DO TTED LINE III. ST ART -UP CHECK EV APORA T OR-F AN SPEED AND RECORD . _______ CHECK CONDENSER-F AN SPEED AND RECORD . _______ AFTER A T LEAST 15 MINUTES R UNNING TIME, RECORD THE FOLLO WING MEASUREMENTS: COMP RESSOR AMPS (L ...

Fabricante Bryant Categoría Air Conditioner

Los documentos del dispositivo Bryant 576b que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Bryant
- manuales de instrucciones 576b
- hojas de producto Bryant
- folletos informativos
- o etiquetas energéticas Bryant 576b
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Bryant 576b.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Bryant 576b, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Bryant 576b. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Bryant 576b.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Bryant 576b, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Bryant 576b. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Bryant 576b.

El manual de instrucciones completo de Bryant debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Bryant 576b - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Bryant 576b, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Bryant 576b que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Bryant 576b - que deben facilitarnos los primeros pasos durante el uso de Bryant 576b
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Bryant 576b
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Bryant 576b en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Bryant 576b?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Bryant 576b, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Bryant 576b probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)