Summary
  • Bryant 576b - page 1

    Cancels : II 569C-7 2-4 II 569C-72 -5 8/15/00 IMPORT ANT — READ BEFORE INST ALLING 1. Read an d become fam iliar w ith these install ation instruc tions b efore insta lling t his unit (Fig . 1). 2. Be sure the i nst alla tion conf orms t o all a ppl icab le local a nd na tion al code s. 3. These instru ctions co ntain i mportant i nforma tion fo ...

  • Bryant 576b - page 2

    — 2 — INST ALLA TION NO TE: When inst alli ng any a cces sory i tem, see the m anuf ac- turer’s installation instructions packaged with the accessory . A quali f ie d age nc y must us e f ac t ory - au th orize d ki ts or acc e s- sories when mo dify ing this unit. The 569 C072, 090, and 1 20 uni ts use hermet ic compr essors . The 576B 09 0, ...

  • Bryant 576b - page 3

    — 3 — T a ble 1 — Ph ysical Data LEGEND *Unit is factory supplied w ith holding charge only . †T y pical operating charge with 25 f t of interconnec ting piping. **Storage capacity of condenser coil with coil 80% fu ll of liquid R-22 at 124 F . NO TE: Unit 576B120 has one step of unloading. Full load is 100% of capacity , and one step of un ...

  • Bryant 576b - page 4

    — 4 — DIMENSIONS (f t- i n. ) UNIT A B C D E F With Alum inum Coils (Standar d) 569C072 1-6 1 / 2 1-2 3 / 4 —1 - 2 1 / 4 1-4 5 / 16 2-9 5 / 16 569C090 1-8 1-6 1 / 2 2-9 13 / 16 1- 3 2- 5 / 16 3-5 7 / 16 569C120 1-9 1-8 2-0 1- 3 2- 5 / 16 3-5 7 / 16 576B090 1-6 1-4 3 / 4 2-9 13 / 16 1- 3 2- 5 / 16 3-5 7 / 16 576B102 1-7 1-5 2-9 13 / 16 1-3 2- ...

  • Bryant 576b - page 5

    — 5 — B. Filter Drier and Moistu re Indica tor The fil ter d rier i s factor y ins talled. Mois ture in dicat or i s a field-ins talled acc essory and s hould be instal led just aft er liqui d line s hutof f valv e at th e evapo rat or coil . Do no t use a receiver . A receiver is not supplied with the unit and s hould not be us ed. NO TE: Unit ...

  • Bryant 576b - page 6

    — 6 — the current within 10%. Use the formula shown in T able 4, Note 2, to de termine the percent vo ltage imbal ance. Ope rat ion o n impr oper line volta ge or exces sive ph ase im bala nce cons tit utes abu se a nd may cau se dama ge t o elec trica l co mponen ts. Su ch op era- tion would invalidate any appli cable w arranty . 4. In sula te ...

  • Bryant 576b - page 7

    — 7 — T ab le 4 — Ele ctrical Data LEGEND NO TES: 1. In compliance with NEC requirements f or multimotor and combina- tion load equipment (refer to NEC Ar ticles 430 and 440), the over- current protective de vice f or t he unit shall be fuse or HA CR breaker . The Canadian units m a y be fuse or circuit breaker . 2. Unbalanced 3-Pha se Suppl ...

  • Bryant 576b - page 8

    — 8 — VI. A CCESSOR Y INST ALLA TION At t his ti me a ny requi red access ories shoul d be in stalled on the un it. Refer to T a ble 5 for a vailabl e ac cessorie s . Con trol wiri ng informat ion is provid ed in the unit w iri ng book. T able 5 — Accesso ry List PRE-ST ART -UP Procee d as follows to i nspect and pr epare the unit for initial ...

  • Bryant 576b - page 9

    — 9 — ST ART -UP I. ST ART -UP AND ADJUSTMENTS A. Chec king Co oling Contr ol Operation Start an d check the uni t for proper co olin g contro l opera tion as fol lo w s: 1. Plac e room ther mostat SYST EM swi tch i n OFF posi- tion. Obs erve tha t blow er moto r starts w hen F AN switch is placed in ON position and s huts down when F AN switc ...

  • Bryant 576b - page 10

    — 10 — SER VICE I. CLEANING Inspe ct unit interi or at t he beginn ing of each co oling se ason and as ope ratin g condition s require . A. Condenser Coil Inspect co il monthly . Clean conden ser coil an nually , or as requir ed by loca tion and ou tdoor-air conditions. Clean coil as fo llows: 1. Turn off unit power and tag disconnect. 2. Remov ...

  • Bryant 576b - page 11

    — 11 — IV . CAP A CITY CONTROL (576B12 0 Only) A suction pressu re-actuated u nloader con trols 2 cy linders and provides capacity control. Unloa ders are fa ctory set (see T able 1) , but may b e field adjus ted: A. Contr ol Set Po int The c ontro l se t po int ( cylin der l oad p oint ) is adju stab le from 0 to 85 psig . T o adjust, turn con ...

  • Bryant 576b - page 12

    — 12 — VIII. REFRIGERANT SER VICE POR TS Eac h unit has 3 s ervic e port s: on e on th e suc tion li ne , on e on the liq uid line, and on e on the comp resso r discha rge line. Be sure caps on the po rts are tight. IX. H IGH FL O W V AL V ES Located on the compres sor hot gas and suction tubes are High Flow V alves . Large black plastic c aps ...

  • Bryant 576b - page 13

    — 13 — TROUBLESHOO TING GUIDE NO TE: See Fig. 15 and 16 for component arrangements. SYMPT OM CA USE REMED Y Compressor does not run — Contactor open P ower off . Restore power . Fuses blown. Replace with correct fuses after finding cause and correcting. T ransformer open/shor ted. Replace transformer if primar y windings are receiving power a ...

  • Bryant 576b - page 14

    Copyright 20 00 Br yant H eating & Coo ling Sy stems 801 CA T ALOG NO. 5356-90 3 LEGEND FOR FIG. 15 AND 16 C— Contactor , Compressor CAP — Capacitor CB — Circuit Breaker CH — Crankcase Heater CLO — Compressor Lockout COMP — Compres sor Moto r CO TP — Compressor T emperature Protection EQUIP — Equipment GND — Ground HPS — Hig ...

  • Bryant 576b - page 15

    CL-1 ST ART -UP CHECKLIST I. PRELIMINAR Y INFORMA TION OUTDO OR: MODE L NO . ____________ ______ _____ _________ __ SERIAL NO . ___ _____ _________ _____ ______ ________ INDOOR: AI R HANDL ER MAN UF ACTUR ER _____ _________ ______________ _____ ______ ________ ______ _____ ___ MODE L NO . _____________ ______ _____ _________ __ SERIAL NO . ___ ____ ...

  • Bryant 576b - page 16

    Copyright 20 00 Br yant H eating & Cool ing Sy stems 801 CL-2 CA T ALOG NO . 5356-903 CUT ALONG DOT TED LINE CUT ALONG DO TTED LINE III. ST ART -UP CHECK EV APORA T OR-F AN SPEED AND RECORD . _______ CHECK CONDENSER-F AN SPEED AND RECORD . _______ AFTER A T LEAST 15 MINUTES R UNNING TIME, RECORD THE FOLLO WING MEASUREMENTS: COMP RESSOR AMPS (L ...

メーカー Bryant カテゴリー Air Conditioner

Bryant 576bのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 576bの取扱説明書
- Bryantの製品カード
- パンフレット
- またはBryant 576bの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bryant 576bの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bryant 576bの取り付け説明書、サービスマニュアル、簡易説明書、またはBryant 576bのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bryant 576bの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bryant 576bデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBryant 576bを使用するのを助ける技術的文書のことです。説明書は通常、全てのBryant 576bユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bryantの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bryant 576bの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBryant 576bの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bryant 576bに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bryant 576bデバイスの基本機能を使うにあたってのヒント。 Bryant 576bのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bryant 576bに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBryant 576bのメーカー/サービスへの連絡先に関する情報。

Bryant 576bについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBryant 576bの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBryant 576bで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)