    F or m No . PD S 502A. 24.1 HORIZONT AL INDOOR SINGLE P A CKA GE COOLING UNITS Single P ac kage Coo ling Un its F eaturing: • compac t design • flexibili ty • eas y main tena nce • high qu ality and rel iability • quiet and effic ient scroll co mpressor techn olog y FEA TURES /BENEF ITS All in o ne pac kage — high coo ling efficie ncy , ...

  • Bryant 502A - page 2

    2 T ABLE OF CONTENTS Pa g e F eatures/Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Model Nu mber Nome nclature . . . . . . . . . . . . . . . . . . . . . . . . . 2 ARI Capacit y Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Ph ysical Data . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Bryant 502A - page 3

    3 PHYSICAL D A T A LEGEND *Shipping weights include base unit plus packaging. † If components are to be split, additional refrigerant will be needed. **Use T ype L copper only . NO TE: If components are to be split, the maxim um length of refrigerant tubing to be used is 50 equivalent ft, assuming components will be installed in same horizontal p ...

  • Bryant 502A - page 4

    4 FIELD-INST ALLED A CCESSORIES Thermo stat and Subbase — Attract i v e wall-mo unted 24-v access or y provi des pr eci se te mperat ure c ontr ol. Auto matic and Manu al changeo ver mo dels av ailab le. A thermostat s ubbase is av ailab le that works w ith Cycle-L OC ™ circuitr y . If a saf ety device tr ips, comp ress or lo cks out and subbas ...

  • Bryant 502A - page 5

    5 B ASE UNI T DIMENSION S DIMENSIONS (ft-in.) UNIT 502A ABCDE 024 2-5 2-1 5 / 8 1- 5 3 / 4 1-2 1-1 036 2-4 3 / 4 2-2 1- 5 3 / 4 1-2 1-1 048 2-5 2-3 1-11 5 / 8 1-8 7 / 8 1-7 7 / 8 060 2-4 3 / 4 2-2 3 / 4 1-11 5 / 8 1-8 7 / 8 1-7 7 / 8 Unit Compone nt Locations ...

  • Bryant 502A - page 6

    6 SELECTION PROCEDURE (with e xample) I DETERMINE COO LING REQUIREMENTS A T DESIGN CONDITIONS. Given: Gross C ooling Capacity Required (TC) . . . . . . . . . . . . . . . . . . . . . . . . . 39,00 0 Btuh Sensib le Heat Capaci ty (SHC) . . . . . . . . . . . . 30,50 0 Btuh T emperature of Air Entering Condenser . . . . . . . . . . . 95 F T emperature ...

  • Bryant 502A - page 7

    7 PERFORMANCE D A T A (cont) GROSS COOLING CAP A CITIES (cont) LEGEND NO TES: 1. Perf or m ance based on nomin al conden ser airflow l isted in physical da ta table on page 3 . 2. SHC is ba sed on 80 F db te mperature of air e nteri ng the co il. Below 80 F db, subtract (corr factor x cfm) from SHC. Above 80 F db , add (co rr factor x cfm) t o SHC. ...

  • Bryant 502A - page 8

    8 PERFORMANCE D A T A (cont) BEL T DRIVE EV APORA T OR F AN PERFORMANCE (Spec ial Or der Only , Pricing an d or dering on related pri ce pages.) LEGEND NO TE: Pulley setting must be adjusted to limit cfm to 450 cfm/ton maximum. Unit operation bey ond that limit may result in blo w-off and condensate problems . CONDENSER F AN PERFORMANCE LEGEND kW ? ...

  • Bryant 502A - page 9

    9 CONTR OLS OPERA TING SEQUENCE Cooling 1. The r mosta t call s f or co oling . a. Indoor (e v aporator) f an rela y is energiz ed and starts e vap orato r f an. b . Compr essor contact or is energiz ed to star t compre ssor and conde nser fa n (up to a 5-min ute dela y on single- phase u nits). 2. When room the r mostat is satisfi ed, the e v apor ...

  • Bryant 502A - page 10

    10 ELECTRICAL D A T A (cont) ELECTRIC HEA TER ST A TIC PRESSURE DR O P (in. wg) NO TE: Abov e el ectric he aters are not UL or CSA listed f or use with optional hi gh-static ev apora tor-f an motor (048, 060 units only). TYPICAL WIRING SCHEMA TICS ELEC TRIC H EA TER UNIT 88EN UNIT 502A MIN CFM UNIT CFM 600 800 1000 1200 1400 1600 1800 2000 2200 005 ...

  • Bryant 502A - page 11

    11 TYPICAL WIRING SCHEMA TICS (cont) LEGEND AHA — Adjustab le Heat Anticipator C — Contactor Compressor CAP — Capacitor CB — Circuit Breaker CC — Cooling Com pensator CDT — Compressor Discharge T hermostat COMP — Comp ressor M otor EQUIP — Equip ment FU — Fuse GND — Ground HPS — High-Pressure Switch HR — Heater Relay IFC — ...

  • Bryant 502A - page 12

    12 TYPICAL WIRING SCHEMA TICS (cont) LEGEND AHA — Adjustab le Heat Anticipator C — Contactor Compressor CAP — Capacitor CB — Circuit Breaker CC — Cooling Com pensator CDT — Compressor Discharge T hermostat CH — Crankcase Hea ter COMP — Comp ressor M otor EQUIP — Equip ment GND — Ground HPS — High-Pressure Switch HR — Heater ...

  • Bryant 502A - page 13

    13 TYPICAL WIRING SCHEMA TICS (cont) LEGEND AHA — Adjustab le Heat Anticipator BKR W/A T — Breaks wit h Amp T urns C — Contactor Compressor CC — Cooling Com pensator CLO — Comp ressor L ockou t COMP — Comp ressor M otor CT — Current T ransf ormer EQUIP — Equip ment GND — Ground HPS — High-Pressure Switch IFC — Indoor -Fan Cont ...

  • Bryant 502A - page 14

    14 TYPICAL PIPING AND WIRING APPLICA TION D A T A OUTDOOR-AIR TEMPERA T URE OPERA TING LIMIT S (F) Field Splitting Ins tructions — If c omp onen ts ar e s plit , ma xi- mum length of ref rigerant tubing to be us ed is 50 ft, as suming compon ents are ins talled in same hor iz ontal pl ane. Co ndenser ma y be moun ted up to 12-ft a bov e e va pora ...

  • Bryant 502A - page 15

    15 GUIDE S PECIFICA TIONS INDOOR P A CKA GED UNIT HV AC GUIDE SPECIFICA TIONS — SECTION 157 87 SIZE RANGE: 2 T O 5 T ONS, NOMINAL BR Y ANT MODEL NUMBER: 502A PA R T 1 — GENERAL 1.01 SYSTEM DESCRIPTION Indoor mo unted, electrically c ontrolled pac kaged horizon- tal coo ling unit uti lizing a her metic typ e scroll compre ssor . 1.02 QU ALITY AS ...

  • Bryant 502A - page 16

    Copyright 2001 Bryant Heating & Cooling Systems Printed in U.S . A. 1-01 Catalog No. 5250-200 SPECIFICATIONS SUBJE CT TO CHANGE WITHOUT NOTICE UNIT MUST BE INST ALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS GUIDE SPECIFICA TIONS (cont) 3. Co mpressor Cycle De lay: Pre ven ts compress or from restar ting f or a minimum of 5 min utes after s ...

Fabricante Bryant Categoría Air Conditioner

Los documentos del dispositivo Bryant 502A que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Bryant
- manuales de instrucciones 502A
- hojas de producto Bryant
- folletos informativos
- o etiquetas energéticas Bryant 502A
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Bryant 502A.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Bryant 502A, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Bryant 502A. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Bryant 502A.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Bryant 502A, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Bryant 502A. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Bryant 502A.

El manual de instrucciones completo de Bryant debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Bryant 502A - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Bryant 502A, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Bryant 502A que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Bryant 502A - que deben facilitarnos los primeros pasos durante el uso de Bryant 502A
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Bryant 502A
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Bryant 502A en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Bryant 502A?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Bryant 502A, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Bryant 502A probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)