Инструкция обслуживания Bryant 502A

16 страниц 0.69 mb
Скачать

Перейти на страницу of 16

Summary
  • Bryant 502A - page 1

    F or m No . PD S 502A. 24.1 HORIZONT AL INDOOR SINGLE P A CKA GE COOLING UNITS Single P ac kage Coo ling Un its F eaturing: • compac t design • flexibili ty • eas y main tena nce • high qu ality and rel iability • quiet and effic ient scroll co mpressor techn olog y FEA TURES /BENEF ITS All in o ne pac kage — high coo ling efficie ncy , ...

  • Bryant 502A - page 2

    2 T ABLE OF CONTENTS Pa g e F eatures/Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Model Nu mber Nome nclature . . . . . . . . . . . . . . . . . . . . . . . . . 2 ARI Capacit y Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Ph ysical Data . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Bryant 502A - page 3

    3 PHYSICAL D A T A LEGEND *Shipping weights include base unit plus packaging. † If components are to be split, additional refrigerant will be needed. **Use T ype L copper only . NO TE: If components are to be split, the maxim um length of refrigerant tubing to be used is 50 equivalent ft, assuming components will be installed in same horizontal p ...

  • Bryant 502A - page 4

    4 FIELD-INST ALLED A CCESSORIES Thermo stat and Subbase — Attract i v e wall-mo unted 24-v access or y provi des pr eci se te mperat ure c ontr ol. Auto matic and Manu al changeo ver mo dels av ailab le. A thermostat s ubbase is av ailab le that works w ith Cycle-L OC ™ circuitr y . If a saf ety device tr ips, comp ress or lo cks out and subbas ...

  • Bryant 502A - page 5

    5 B ASE UNI T DIMENSION S DIMENSIONS (ft-in.) UNIT 502A ABCDE 024 2-5 2-1 5 / 8 1- 5 3 / 4 1-2 1-1 036 2-4 3 / 4 2-2 1- 5 3 / 4 1-2 1-1 048 2-5 2-3 1-11 5 / 8 1-8 7 / 8 1-7 7 / 8 060 2-4 3 / 4 2-2 3 / 4 1-11 5 / 8 1-8 7 / 8 1-7 7 / 8 Unit Compone nt Locations ...

  • Bryant 502A - page 6

    6 SELECTION PROCEDURE (with e xample) I DETERMINE COO LING REQUIREMENTS A T DESIGN CONDITIONS. Given: Gross C ooling Capacity Required (TC) . . . . . . . . . . . . . . . . . . . . . . . . . 39,00 0 Btuh Sensib le Heat Capaci ty (SHC) . . . . . . . . . . . . 30,50 0 Btuh T emperature of Air Entering Condenser . . . . . . . . . . . 95 F T emperature ...

  • Bryant 502A - page 7

    7 PERFORMANCE D A T A (cont) GROSS COOLING CAP A CITIES (cont) LEGEND NO TES: 1. Perf or m ance based on nomin al conden ser airflow l isted in physical da ta table on page 3 . 2. SHC is ba sed on 80 F db te mperature of air e nteri ng the co il. Below 80 F db, subtract (corr factor x cfm) from SHC. Above 80 F db , add (co rr factor x cfm) t o SHC. ...

  • Bryant 502A - page 8

    8 PERFORMANCE D A T A (cont) BEL T DRIVE EV APORA T OR F AN PERFORMANCE (Spec ial Or der Only , Pricing an d or dering on related pri ce pages.) LEGEND NO TE: Pulley setting must be adjusted to limit cfm to 450 cfm/ton maximum. Unit operation bey ond that limit may result in blo w-off and condensate problems . CONDENSER F AN PERFORMANCE LEGEND kW ? ...

  • Bryant 502A - page 9

    9 CONTR OLS OPERA TING SEQUENCE Cooling 1. The r mosta t call s f or co oling . a. Indoor (e v aporator) f an rela y is energiz ed and starts e vap orato r f an. b . Compr essor contact or is energiz ed to star t compre ssor and conde nser fa n (up to a 5-min ute dela y on single- phase u nits). 2. When room the r mostat is satisfi ed, the e v apor ...

  • Bryant 502A - page 10

    10 ELECTRICAL D A T A (cont) ELECTRIC HEA TER ST A TIC PRESSURE DR O P (in. wg) NO TE: Abov e el ectric he aters are not UL or CSA listed f or use with optional hi gh-static ev apora tor-f an motor (048, 060 units only). TYPICAL WIRING SCHEMA TICS ELEC TRIC H EA TER UNIT 88EN UNIT 502A MIN CFM UNIT CFM 600 800 1000 1200 1400 1600 1800 2000 2200 005 ...

  • Bryant 502A - page 11

    11 TYPICAL WIRING SCHEMA TICS (cont) LEGEND AHA — Adjustab le Heat Anticipator C — Contactor Compressor CAP — Capacitor CB — Circuit Breaker CC — Cooling Com pensator CDT — Compressor Discharge T hermostat COMP — Comp ressor M otor EQUIP — Equip ment FU — Fuse GND — Ground HPS — High-Pressure Switch HR — Heater Relay IFC — ...

  • Bryant 502A - page 12

    12 TYPICAL WIRING SCHEMA TICS (cont) LEGEND AHA — Adjustab le Heat Anticipator C — Contactor Compressor CAP — Capacitor CB — Circuit Breaker CC — Cooling Com pensator CDT — Compressor Discharge T hermostat CH — Crankcase Hea ter COMP — Comp ressor M otor EQUIP — Equip ment GND — Ground HPS — High-Pressure Switch HR — Heater ...

  • Bryant 502A - page 13

    13 TYPICAL WIRING SCHEMA TICS (cont) LEGEND AHA — Adjustab le Heat Anticipator BKR W/A T — Breaks wit h Amp T urns C — Contactor Compressor CC — Cooling Com pensator CLO — Comp ressor L ockou t COMP — Comp ressor M otor CT — Current T ransf ormer EQUIP — Equip ment GND — Ground HPS — High-Pressure Switch IFC — Indoor -Fan Cont ...

  • Bryant 502A - page 14

    14 TYPICAL PIPING AND WIRING APPLICA TION D A T A OUTDOOR-AIR TEMPERA T URE OPERA TING LIMIT S (F) Field Splitting Ins tructions — If c omp onen ts ar e s plit , ma xi- mum length of ref rigerant tubing to be us ed is 50 ft, as suming compon ents are ins talled in same hor iz ontal pl ane. Co ndenser ma y be moun ted up to 12-ft a bov e e va pora ...

  • Bryant 502A - page 15

    15 GUIDE S PECIFICA TIONS INDOOR P A CKA GED UNIT HV AC GUIDE SPECIFICA TIONS — SECTION 157 87 SIZE RANGE: 2 T O 5 T ONS, NOMINAL BR Y ANT MODEL NUMBER: 502A PA R T 1 — GENERAL 1.01 SYSTEM DESCRIPTION Indoor mo unted, electrically c ontrolled pac kaged horizon- tal coo ling unit uti lizing a her metic typ e scroll compre ssor . 1.02 QU ALITY AS ...

  • Bryant 502A - page 16

    Copyright 2001 Bryant Heating & Cooling Systems Printed in U.S . A. 1-01 Catalog No. 5250-200 SPECIFICATIONS SUBJE CT TO CHANGE WITHOUT NOTICE UNIT MUST BE INST ALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS GUIDE SPECIFICA TIONS (cont) 3. Co mpressor Cycle De lay: Pre ven ts compress or from restar ting f or a minimum of 5 min utes after s ...

Производитель Bryant Категория Air Conditioner

Документы, которые мы получаем от производителя устройства Bryant 502A мы можем разделить на несколько групп. Это в частности:
- технические чертежи Bryant
- инструкции обслуживания 502A
- паспорта изделия Bryant
- информационные брошюры
- энергетические этикетки Bryant 502A
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Bryant 502A.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Bryant 502A, инструкции обслуживания, короткие инструкции или инструкции пользователя Bryant 502A. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Bryant 502A.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Bryant 502A, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Bryant 502A пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Bryant 502A.

Полная инструкция обслуживания Bryant, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Bryant 502A - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Bryant 502A, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Bryant 502A, которое найдем в данном документе
3. Советы по использованию основных функций устройства Bryant 502A - которые должны облегчить нам первые шаги во время использования Bryant 502A
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Bryant 502A
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Bryant 502A в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Bryant 502A?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Bryant 502A, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Bryant 502A со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)